Sigenergy 400H2

360 kW Grid-tie Three-phase
Datasheet PDF
Rated AC (kW)
360.00
Strong · top 2%
Euro eff. (%)
98.8
Strong · top 15%
MPPT
14
Strong · top 3%
Max DC (V)
1500
Strong · top 23%
Weight (kg)
150.0
Strong · top 19%
Warranty (yrs)
-
Not published

The Sigen PV series is built for large-scale commercial and industrial installations, where both raw power and ease of scaling matter equally. Inverters in this line feature a built-in energy management system (EMS), allowing up to 100 units to be connected in parallel without an external data logger - a real time-saver when designing and commissioning sprawling PV farms. Its high rated output sets a new industry benchmark for commercial-grade inverters, helping maximize project value while reducing the number of devices needed on site. Safety is reinforced by an advanced arc fault circuit interrupter (AFCI) with detection range up to 500 meters, a feature that matters most on large string arrays with long cable runs. An IP66-rated enclosure paired with smart air cooling allows outdoor deployment without extra protective housing, regardless of weather conditions. Nine independent MPPT trackers give installers the flexibility to adapt string configurations to irregular roof layouts or ground-mount terrain. The Sigen PV series fits projects where reliability, scalability, and low long-term maintenance costs are the priority throughout the lifetime of the solar installation.

Ranking

238 inverters from 100 to 500 kW
Metric This inverter Median Position in class Rank in class
European efficiency 98.8% 98.5% Strong · top 15% 11
MPPT trackers 14 8 Strong · top 3% 5
Max DC input voltage 1500 V 1100 V Strong · top 23% 1
Weight per kW 0.4 0.7 Strong · top 19% 46
Warranty - 5 yrs Not published -
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 360 kW Continuous output
Max AC power 396.00 kW Short-term output above the rating
Max apparent power 396.00 kVA
Phases Three-phase
Nominal AC voltage 800 V
Max AC current 285.8 A
Grid frequency 50 Hz
Power factor 0.8 leading ~ 0.8 lagging
Harmonic distortion (THD) 1.0 %
Max DC voltage 1500 V Caps the string length
MPPT voltage range 480 to 1500 V
Start-up voltage 520 V
MPPT trackers 14 2 strings each
Max input current per MPPT 40.0 A Must exceed the panel's Imp
Max short-circuit current per MPPT 60.0 A Must exceed the panel's Isc
European efficiency 98.8 % Weighted across part loads
Max efficiency 99.0 % Best single operating point
Dimensions 875 × 1080 × 409 mm Height × width × depth
Weight 150.0 kg 0.4 kg per kW
Enclosure IP66
Cooling forced-air
Noise 71 dB
Operating temperature -30 to 60 °C
Max humidity 100 %
Max altitude 5000 m
Interfaces Wi-FiEthernet
Protocols Fast EthernetPLC (AC)WLAN
Protection AFCIDC switchSurge protection

Pros and cons

5 positive · 2 caution
What owners get
Built-in EMS for up to 100 units in parallel

The integrated energy management system allows parallel connection of up to 100 inverters without an external data logger, reducing design and commissioning time while cutting extra communication hardware costs for large PV farms.

AFCI detection range up to 500 m

The advanced arc-fault circuit interrupter (AFCI) with a detection range of up to 500 meters exceeds typical commercial/industrial segment standards, which matters for extensive PV strings and long cable runs on large rooftop and ground-mount installations.

IP66 enclosure with smart air cooling

IP66 ingress protection combined with intelligent air cooling allows outdoor installation without additional protective housing regardless of weather conditions - standard across the M1 lineup of the Sigen PV series (50-125 kW).

9 MPPT trackers in a single inverter

Nine independent MPPT trackers provide high flexibility for string configuration, which is useful for unconventional roof or ground layouts where modules face varying orientations and tilt angles.

High unit power rating up to 125 kW

Series models (50, 60, 80, 100, 110, 125 kW) with max DC voltage up to 1100 V allow fewer devices on site for the same installed capacity, reducing installation and AC/DC wiring costs.

Trade-offs
Young manufacturer with limited track record

Sigenergy was founded in 2022, meaning a shorter field-operation history compared to established tier-1 competitors like Huawei, Sungrow, or SMA. For commercial projects evaluated over a 20-25 year horizon, the lack of long-term reliability data can be a meaningful risk factor in bankability assessments.

Standard warranty capped at 10 years, extension sold separately

The base warranty for PV series models (e.g., 50 kW, 99.9 kW, 125 kW) is 10 years, with extension to 20 years requiring a separately purchased warranty package. Some tier-1 competitors in the C&I segment offer a longer standard warranty without an extra fee.

Inverter Power Euro eff. MPPT Weight Difference
Sigenergy 400H2 360 kW 98.8% 14 150.0 kg You are here
360 NX3 363 kW 98.6% 6 122.0 kg +3.0 kW, -8 MPPT, 28.0 kg lighter
PSIT-350K-KH-UT 352 kW 98.8% - 124.0 kg -8.0 kW, 26.0 kg lighter
PSIT-350K-K-UT 352 kW 98.8% - 124.0 kg -8.0 kW, 26.0 kg lighter
SOFAR 350KTLX0 350 kW 98.8% - 113.0 kg -10.0 kW, 37.0 kg lighter
SG350HX 350 kW 98.8% 12 116.0 kg -10.0 kW, -2 MPPT, 34.0 kg lighter
X3-GRD-350K-HV 350 kW 98.8% 6 130.0 kg -10.0 kW, -8 MPPT, 20.0 kg lighter
HYX-S350K-HT 350 kW 98.8% 6 130.0 kg -10.0 kW, -8 MPPT, 20.0 kg lighter
S6-GU350K-EHV-M12 350 kW 98.7% - 134.0 kg -10.0 kW, 16.0 kg lighter

About the Sigen PV series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

How many Sigen PV inverters can be connected in parallel in a single installation?
The built-in EMS allows up to 100 Sigen PV units to be connected in parallel without an external data logger. This is a major advantage for large-scale PV farms, since installers don't need to purchase and configure a separate data acquisition device for multiple inverters, which speeds up design and commissioning of large commercial or industrial installations.
Can Sigen PV inverters be installed outdoors without a canopy or protective enclosure?
Yes, the enclosure carries an IP66 ingress protection rating, and intelligent air cooling is managed internally, allowing Sigen PV inverters to be mounted outdoors without additional shelter. They perform reliably in a range of weather conditions, including high humidity and dust, which are common at large PV farms on open ground or industrial rooftops.
How does the arc fault circuit interrupter (AFCI) in Sigen PV inverters work and what is its range?
The AFCI in the Sigen PV series detects electric arcing along cable runs up to 500 meters, which matters for extensive PV strings in large commercial installations. The system reacts automatically to detected hazards, improving fire safety, especially where DC wiring runs long distances between the panels and the inverter.
How many MPPT trackers does the Sigen PV series have, and is it suitable for unusual roof layouts?
The Sigen PV series features nine independent MPPT trackers, allowing flexible string configuration for unusual surfaces such as roofs with obstructions, varying tilt angles, or partial shading. This lets designers optimize each group of panels independently instead of compromising by combining them into a single lower-performing string.
Which installations benefit most from choosing a Sigen PV inverter instead of several smaller units?
The high rated power of the Sigen PV series allows a large installation to be served with fewer devices, reducing installation materials, wiring, and site space compared to using many smaller inverters. The built-in EMS and the ability to parallel up to 100 units also lower maintenance costs over the operational lifetime of a PV farm.
Do Sigen PV inverters require an external data logger to monitor performance?
No, thanks to the built-in energy management system (EMS), Sigen PV inverters do not require an additional data logger even when operating up to 100 units in parallel. This reduces extra hardware and potential points of failure, which matters for large installations where monitoring needs to remain stable and simple to maintain.