Skip to main content

Senergy SE 50KTL-Q3/G2

50 kW Grid-tie Three-phase
Datasheet PDF
Rated AC (kW)
50.00
Typical for its class
Euro eff. (%)
97.9
Weak · bottom 20%
MPPT
-
Not published
Max DC (V)
1100
Typical · median 1100 V
Weight (kg)
42.0
Strong · 33.0 kg below median
Warranty (yrs)
5
Typical · median 5 yrs

The Senergy SE KTL-G2 series comprises three-phase transformerless inverters built for commercial and industrial PV sites, spanning power classes from 30 to 60 kW. With an extensive multi-MPPT architecture (up to four trackers and four strings per tracker), these units handle roofs with varied orientations and uneven irradiance well, cutting losses caused by partial shading. An IP66-rated enclosure paired with natural cooling (30 kW model) or smart cooling (40-60 kW models) allows for outdoor installation without extra protective housing, which meaningfully lowers deployment costs. The series stands out for its string-level diagnostics, enabling faster fault detection and maximizing overall energy yield. An optional AFCI 2.0 module and integrated PID protection add fire safety and shield modules from potential-induced degradation. Configuration and firmware updates can be handled remotely, while quick commissioning via a mobile app shortens system startup time. This makes it a strong fit for integrators and investors seeking a dependable inverter for large rooftop and ground-mount installations that combines high efficiency with easy servicing and real-time consumption monitoring.

Ranking

679 inverters from 30 to 100 kW
Metric This inverter Median Position in class Rank in class
European efficiency 97.9% 98.2% Weak · bottom 20% 416
MPPT trackers - 4 Not published -
Max DC input voltage 1100 V 1100 V Typical 12
Weight per kW 0.8 1.2 Strong · top 18% 113
Warranty 5 yrs 5 yrs Typical 45
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 50 kW Continuous output
Max apparent power 55.60 kVA
Phases Three-phase
Nominal AC voltage 400 V 320V-520V (Adjustable)
Max AC current 84.3 A
Grid frequency 50 Hz Range 45Hz-55Hz/55Hz-65Hz (Adjustable)
Power factor 0.8 LD - 0.8 LG
Harmonic distortion (THD) 3.0 %
Max DC input power 75.00 kW DC/AC ratio 1.50
Max DC voltage 1100 V Caps the string length
MPPT voltage range 180 to 1000 V
Start-up voltage 200 V
Max input current per MPPT 40.0 A Must exceed the panel's Imp
Max short-circuit current per MPPT 50.0 A Must exceed the panel's Isc
European efficiency 97.9 % Weighted across part loads
Max efficiency 98.5 % Best single operating point
Dimensions 530 × 635 × 224 mm Height × width × depth
Weight 42.0 kg 0.8 kg per kW
Enclosure IP66
Cooling forced-air
Operating temperature -25 to 60 °C
Max humidity 100 %
Max altitude 4000 m
Interfaces Wi-FiDisplay
Protocols RS485Wi-FiGPRSLAN
Protection DC switchSurge protection
Warranty 5 years Standard manufacturer cover
Certifications IEC 62109-1IEC 62109-2VDE-AR-N 4105EN 50549-1CEI 0-21UNE 206006/206007-1RD 1699/661&413IEC 61727/62116IEC 61683CQC

Pros and cons

5 positive · 2 caution
What owners get
Advanced multi-MPPT architecture

Up to four MPPT trackers with four strings per tracker reduce energy losses on roofs with uneven irradiance or heterogeneous panel orientation, a meaningful advantage over competing commercial inverters in this power class that typically offer only 2-3 trackers.

IP66 enclosure without extra protection

IP66 ingress protection allows outdoor installation without an additional protective enclosure, meaningfully reducing balance-of-system (BoS) costs compared to IP65-rated models that need extra housing in harsh weather conditions.

String-level diagnostics

Monitoring at the individual string level speeds up fault detection (e.g., degradation or shading of a single string) without requiring physical inspection, shortening service response time and minimizing downtime in energy production.

Fire safety and anti-degradation protection

Optional AFCI 2.0 module for DC arc-fault detection combined with integrated PID (potential induced degradation) protection increase installation safety and protect PV module longevity over the system's lifetime.

Fast commissioning via mobile app

Remote configuration, firmware updates, and commissioning through a mobile app shorten the start-up time for commercial installations, reducing on-site labor costs compared to models requiring physical access to the inverter interface.

Trade-offs
Limited brand recognition in the EU market

Compared to established tier-1 C&I inverter suppliers (Huawei, Sungrow, SMA), Senergy has a smaller service and distribution footprint in Europe, which may translate into longer warranty repair turnaround and limited availability of spare parts for integrators.

No clearly confirmed hybrid capability

Available documentation for the SE KTL-G2 series does not indicate native energy storage integration (storage-ready), which, unlike some competing commercial inverters in this power class, may limit flexibility for projects planning future battery expansion.

Alternatives

All Senergy inverters
Inverter Power Euro eff. MPPT Weight Difference
Senergy SE 50KTL-Q3/G2 50 kW 97.9% - 42.0 kg You are here
SUN2000-50KTL-JPM0 50 kW 98.6% 6 71.0 kg +0.7 pp efficiency, 29.0 kg heavier
SUN2000-50KTL-M0 50 kW 98.5% 6 74.0 kg +0.6 pp efficiency, 32.0 kg heavier
Solis-50K-HV 50 kW 98.5% 4 61.0 kg +0.6 pp efficiency, 19.0 kg heavier
MID 50KTL3-X3 50 kW 98.5% - 29.6 kg +0.6 pp efficiency, 12.4 kg lighter
MID 50KTL3-X3 MV 50 kW 98.5% - 29.6 kg +0.6 pp efficiency, 12.4 kg lighter
BNT050KTL 50 kW 98.5% - 44.0 kg +0.5 pp efficiency, 2.0 kg heavier
MAX 50KTL3 LV 50 kW 98.4% - 82.0 kg +0.5 pp efficiency, 40.0 kg heavier
SG50CX 50 kW 98.4% - 62.0 kg +0.5 pp efficiency, 20.0 kg heavier

About the SE KTL-G2 series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

What is the power range of the Senergy SE KTL-G2 inverters and what installations are they suited for?
The SE KTL-G2 series covers power ratings from 30 to 60 kW, making it suitable for commercial and industrial installations, both rooftop and ground-mounted. Thanks to the transformerless architecture, the units maintain high efficiency with a smaller footprint and lower weight than inverters with a transformer. It is a solution for integrators seeking an inverter for medium and large PV systems, not residential microinstallations.
Can the SE KTL-G2 inverter be installed outdoors without an additional enclosure?
Yes, thanks to its IP66 protection rating, the unit withstands dust and powerful water jets, allowing direct outdoor mounting on a building facade or support structure. No additional rain cover or shelter is required, which meaningfully lowers material and labor costs when installing in open terrain or on industrial roofs.
What is the difference between cooling in the 30 kW model versus the 40-60 kW models in the SE KTL-G2 series?
The 30 kW model uses natural, fanless cooling, which reduces energy consumption and eliminates noise, though it is better suited to lower thermal loads. The 40-60 kW models feature intelligent cooling that adjusts dynamically to operating temperature, maintaining stable efficiency at higher power levels and during prolonged full-load operation on hot days.
How many PV strings can be connected to a single SE KTL-G2 inverter?
SE KTL-G2 inverters feature up to four MPPT trackers, each supporting up to four string inputs, giving up to sixteen total string inputs. This extensive MPPT architecture allows optimal configuration for roofs with varying irradiance, different panel tilt angles, and partial shading, minimizing energy production losses.
What does string-level diagnostics in the SE KTL-G2 provide?
String-level diagnostics lets technicians monitor each string's parameters independently, quickly pinpointing a faulty string, a soiled panel, or a wiring issue without physically inspecting the entire array. In practice this shortens repair time and reduces energy production downtime, which matters significantly in large commercial installations.
Is it worth paying extra for the optional AFCI 2.0 module in the SE KTL-G2 inverter?
The AFCI 2.0 module detects electrical arcs caused by, for example, a damaged connector or frayed cable and automatically disconnects the system before ignition can occur. For commercial installations on roofs with flammable roofing or high-value assets, this added fire protection is a sensible investment, especially combined with the integrated PID protection that safeguards the panels.