Skip to main content

Senergy SE 17KTL-D3/G2

17 kW Grid-tie Three-phase
Datasheet PDF
Rated AC (kW)
17.00
Typical for its class
Euro eff. (%)
98.0
Typical · median 98.0%
MPPT
2
Typical · median 2
Max DC (V)
1100
Strong · top 18%
Weight (kg)
20.1
Strong · 17.9 kg below median
Warranty (yrs)
5
Typical · median 5 yrs

The SE KTL-D3/G2 series consists of three-phase grid-tied inverters built for residential installations as well as small and medium commercial and industrial projects. Thanks to its dual MPPT architecture, the unit flexibly adapts to different string configurations, while a wide input voltage range keeps it running stably even under uneven irradiance or partially loaded strings. The transformerless design combined with high string current capacity lets the inverter pair seamlessly with modern, high-power PV modules, reducing the need for extra MPPT channels. An IP66-rated enclosure paired with smart cooling allows installation both indoors and outdoors without concerns about dust or moisture ingress. Optional AFCI 2.0 protection and a type II surge arrester add an extra layer of safety, while remote monitoring and configuration via a mobile app significantly shorten commissioning and service time. This is a solution for installers looking for a compact, reliable inverter that performs just as well in a home system as in a larger commercial project, offering configuration flexibility along with straightforward installation.

Ranking

768 inverters from 12 to 30 kW
Metric This inverter Median Position in class Rank in class
European efficiency 98.0% 98.0% Typical 234
MPPT trackers 2 2 Typical 212
Max DC input voltage 1100 V 1000 V Strong · top 18% 1
Weight per kW 1.2 1.8 Strong · top 20% 146
Warranty 5 yrs 5 yrs Typical 90
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 17 kW Continuous output
Max AC power 18.70 kW Short-term output above the rating
Max apparent power 18.70 kVA
Phases Three-phase
Nominal AC voltage 400 V 260V-510V (Adjustable)
Max AC current 28.6 A
Grid frequency 50 Hz Range 45Hz-55Hz/55Hz-65Hz (Adjustable)
Power factor > 0.99@Rated power (Adjustable 0.8 LD - 0.8 LG)
Harmonic distortion (THD) 3.0 %
Max DC input power 25.50 kW DC/AC ratio 1.50
Max DC voltage 1100 V Caps the string length
MPPT voltage range 160 to 1000 V
Start-up voltage 180 V
MPPT trackers 2
Max input current per MPPT 30.0 A Must exceed the panel's Imp
Max short-circuit current per MPPT 40.0 A Must exceed the panel's Isc
European efficiency 98.0 % Weighted across part loads
Max efficiency 98.4 % Best single operating point
Dimensions 460 × 398 × 190 mm Height × width × depth
Weight 20.1 kg 1.2 kg per kW
Enclosure IP66
Cooling forced-air
Operating temperature -25 to 60 °C
Max humidity 100 %
Max altitude 4000 m
Interfaces Wi-FiEthernetDisplay
Protocols RS485Wi-FiGPRSLAN
Protection DC switchSurge protection
Warranty 5 years Standard manufacturer cover
Certifications IEC 62109-1IEC 62109-2VDE-AR-N 4105EN 50549-1CEI 0-21UNE 206006/206007-1RD 1699/661&413IEC 61727/62116AS 4777.2

Pros and cons

5 positive · 2 caution
What owners get
Dual MPPT for string flexibility

Two independent MPPT trackers allow combining strings with different orientation, shading, or length within a single installation, reducing energy losses compared to single-MPPT inverters in this power class.

High compatibility with high-power modules

The transformerless design and high rated string current capacity enable operation with modern 500W+ modules without needing additional MPPT circuits, shortening system design and installation time.

IP66 enclosure for indoor and outdoor mounting

IP66 protection combined with smart cooling allows installation without a dedicated technical room, a key advantage for commercial-industrial sites with limited indoor space.

AFCI 2.0 and Type II surge protection

Optional arc-fault detection (AFCI 2.0) combined with built-in Type II surge protection improves fire safety, aligning with increasingly strict PV installation standards.

Remote monitoring and app-based configuration

Mobile app-based management and commissioning reduce the need for on-site technician presence during configuration, meaningfully cutting commissioning time versus models without remote setup.

Trade-offs
AFCI is optional, not standard

Unlike some competing tier-1 series (e.g., Solplanet ASW-LT-G2 Pro AFCI), arc-fault detection on the SE KTL-D3/G2 is an optional add-on rather than a default feature across all variants - worth confirming when configuring a specific order.

Limited independent reviews and track record

Compared to established tier-1 brands (Huawei, Sungrow, GoodWe), the Senergy KTL-D3/G2 series has a smaller base of independent installer reviews and long-term failure-rate data on the Polish market, making durability harder to assess in practice.

Alternatives

All Senergy inverters
Inverter Power Euro eff. MPPT Weight Difference
Senergy SE 17KTL-D3/G2 17 kW 98.0% 2 20.1 kg You are here
MID 17KTL3-X 17 kW 98.6% 2 23.0 kg +0.6 pp efficiency, 2.9 kg heavier
HYX-S17K-LT 17 kW 98.5% - 44.0 kg +0.5 pp efficiency, 23.9 kg heavier
MID 17KTL3-X3 LV 17 kW 98.5% - 29.6 kg +0.5 pp efficiency, 9.5 kg heavier
MOD 17KTL3-X3 17 kW 98.5% - 17.3 kg +0.5 pp efficiency, 2.8 kg lighter
BNT017KTL 17 kW 98.3% 2 17.0 kg +0.3 pp efficiency, 3.1 kg lighter
SUN2000-17KTL-M0 17 kW 98.3% 2 25.0 kg 4.9 kg heavier
SUN2000-17KTL-M2 17 kW 98.3% 2 25.0 kg 4.9 kg heavier
BluE-17KT-M1 17 kW 98.3% 2 20.7 kg Similar on paper

About the SE KTL-D3/G2 series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

How many MPPT trackers do SE KTL-D3/G2 inverters have and what does that mean in practice?
The SE KTL-D3/G2 series features dual MPPT tracking, allowing two independent strings with different orientation, tilt angle, or shading levels to be connected. This lets installers split panels across two roof sections without losing performance, since the inverter optimizes each string independently.
Can the SE KTL-D3/G2 inverter be installed outdoors?
Yes, the enclosure has an IP66 protection rating, providing full resistance to dust and powerful water jets from any direction. Combined with its smart cooling system, the inverter can be safely mounted outdoors, on a building facade or in a carport, without additional weather shielding.
Does the SE KTL-D3/G2 series work with high-power modern solar panels?
Yes, the transformerless design and high rated string current capacity allow a large number of high-wattage modules to be connected without needing extra MPPT inputs. This makes it well suited for upgrading existing installations with newer, more powerful panels.
What is AFCI 2.0 on the SE KTL-D3/G2 inverter and is it worth enabling?
AFCI 2.0 is an optional DC arc-fault detection feature that automatically shuts down the inverter if it detects arcing caused by damaged cable insulation. Enabling it is worthwhile since it significantly improves fire safety, especially in residential buildings and sites with limited service access.
How is the SE KTL-D3/G2 inverter configured and monitored after installation?
Commissioning and ongoing monitoring are handled through a dedicated mobile app that connects to the inverter locally or remotely. Installers can configure operating parameters, check real-time energy production, and review event history without opening the enclosure, cutting down service visit time considerably.
Is the SE KTL-D3/G2 suitable only for homes, or also for small businesses?
The series is designed as a versatile solution: its three-phase topology and wide input voltage range make it suitable for both residential installations and small commercial or industrial sites. Compact dimensions and flexible string configuration make it easy to adapt to the varying energy needs of a small business.