Skip to main content

NEP NEP-50K

50 kW Grid-tie Three-phase
Datasheet PDF
Rated AC (kW)
50.00
Typical for its class
Euro eff. (%)
-
Not published
MPPT
-
Not published
Max DC (V)
1000
Typical · median 1100 V
Weight (kg)
37.0
Strong · 38.0 kg below median
Warranty (yrs)
-
Not published

The NEP Neptune NEP-KW series comprises transformerless, three-phase commercial inverters built for medium- and large-scale rooftop PV installations on industrial buildings, warehouses, and ground-mount solar farms. The series stands out with an integrated rapid shutdown (RSD) transmitter, meeting installation safety code requirements without needing separate module-level add-on devices, which simplifies system design and reduces material costs. It also delivers intelligent string-level monitoring and I-V curve scanning, letting operators detect shading, soiling, or individual panel faults in real time and respond quickly, which meaningfully cuts downtime and boosts system availability. With built-in PID recovery, the units counteract potential-induced degradation in PV modules, extending the lifespan of the overall installation. A rugged Type 4X/C5 corrosion-resistant enclosure allows deployment in harsh weather conditions, including industrial and coastal environments. Another key advantage is the high 150% DC/AC oversizing ratio, giving system designers the flexibility to install more PV capacity per inverter and lower the levelized cost of energy. The series also supports aluminum conductor wiring, further reducing balance-of-system installation costs. This makes it a strong fit for commercial and industrial installers who prioritize reliability, serviceability, and design flexibility.

Ranking

552 inverters from 30 to 100 kW
Metric This inverter Median Position in class Rank in class
European efficiency - 98.2% Not published -
MPPT trackers - 4 Not published -
Max DC input voltage 1000 V 1100 V Typical 298
Weight per kW 0.7 1.2 Strong · top 7% 35
Warranty - 5 yrs Not published -
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 50 kW Continuous output
Max AC power 55.00 kW Short-term output above the rating
Max apparent power 55.00 kVA
Phases Three-phase
Nominal AC voltage 480 V
Max AC current 66.2 A
Grid frequency 60 Hz
Power factor 0.8 leading - 0.8 lagging
Harmonic distortion (THD) 3.0 %
Max DC voltage 1000 V Caps the string length
MPPT voltage range 160 to 1000 V
Start-up voltage 160 V
Max input current per MPPT 40.0 A Must exceed the panel's Imp
Max short-circuit current per MPPT 63.0 A Must exceed the panel's Isc
Max efficiency 98.8 % Best single operating point
CEC efficiency 98.3 % California Energy Commission weighting
Dimensions 629 × 647 × 252 mm Height × width × depth
Weight 37.0 kg 0.7 kg per kW
Enclosure Type 4X
Cooling forced-air
Operating temperature -30 to 60 °C
Max humidity 100 %
Max altitude 4000 m
Interfaces Wi-FiEthernetDisplay
Protocols Modbus RTURS485EthernetCellularWi-Fi
Protection AFCIDC switchSurge protection
Certifications UL1741SBUL1741SAIEEE 1547-2018UL1699BUL1998FCC Part15 ClassBCalifornia Rule 21HECO Rule 14HNEC 690.12-2020CAN-CSA C22.2107.1-1

Pros and cons

5 positive · 2 caution
What owners get
Integrated RSD transmitter

The built-in Rapid Shutdown transmitter removes the need for separate module-level RSD devices, reducing both material cost and installation time for NEC 2017/2020-compliant commercial PV systems, per manufacturer data.

Up to 150% DC/AC oversizing

The 150% DC/AC ratio allows more PV capacity per inverter than the typical 130% offered by many competitors, reducing the number of units required and lowering per-kWp installation cost.

High conversion efficiency

Per the datasheet (NEP-33~50kW, Jan 2024), the series reaches 98.8% max efficiency and 98.3% CEC efficiency, putting it on par with tier-1 segment leaders such as Huawei and Sungrow.

Type 4X/C5 enclosure rating

The Type 4X/C5 ingress-protection and corrosion-resistance rating allows installation in coastal and industrial environments without additional enclosures, extending the unit's service life in harsh conditions.

Smart string monitoring and PID recovery

Built-in I-V curve scanning at string level plus integrated PID recovery enable real-time detection of shading or faults and counteract potential-induced degradation, reducing service downtime and improving system availability.

Trade-offs
Base warranty shorter than tier-1 peers

NEP's standard warranty is 12 years, extendable to 25 years at additional cost, while some tier-1 competitors (e.g., SMA, Huawei) offer longer base coverage at no extra charge, raising the total cost of ownership for commercial installations.

Less established utility-scale track record

Northern Electric Power (NEP) has a shorter history in large-scale commercial PV deployments compared to brands like Huawei, Sungrow, or SMA, which can affect perceived bankability when financing large PV farms.

Alternatives

All NEP inverters
Inverter Power Euro eff. MPPT Weight Difference
NEP NEP-50K 50 kW - - 37.0 kg You are here
SUN2000-50KTL-JPM0 50 kW 98.6% 6 71.0 kg 34.0 kg heavier
SUN2000-50KTL-M0 50 kW 98.5% 6 74.0 kg 37.0 kg heavier
Solis-50K-HV 50 kW 98.5% 4 61.0 kg 24.0 kg heavier
BNT050KTL 50 kW 98.5% - 44.0 kg 7.0 kg heavier
MAX 50KTL3 LV 50 kW 98.4% - 82.0 kg 45.0 kg heavier
SG50CX 50 kW 98.4% - 62.0 kg 25.0 kg heavier
Solis-50K 50 kW 98.4% 4 63.0 kg 26.0 kg heavier
XG50KTR 50 kW 98.4% 4 50.0 kg 13.0 kg heavier

About the NEPTUNE NEP-KW series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

What is the integrated RSD transmitter in NEP NEPTUNE NEP-KW inverters, and does it require extra modules?
RSD (Rapid Shutdown) cuts DC voltage at the PV module level during an emergency, such as a fire. In the NEP-KW series, the RSD transmitter is built into the inverter, eliminating the need for separate external RSD modules on each panel. This simplifies system design, speeds up installation, and lowers material costs while still meeting the safety codes required for commercial PV projects.
How does intelligent string monitoring and I-V curve scanning work on NEP-KW inverters?
The inverter continuously tracks each string's performance and periodically runs an I-V curve scan to detect shading, soiling, or a faulty panel without sending a technician onto the roof. This fast diagnostic lets O&M teams know exactly which string to check, reducing downtime and improving the availability - and therefore the energy yield - of the overall PV plant.
What is the PID regeneration function in the NEP NEPTUNE inverter, and why does it matter?
PID (Potential Induced Degradation) is a performance loss in PV modules caused by a voltage difference between the cells and the frame, which gradually reduces system output over time. The built-in PID regeneration feature on NEP-KW inverters automatically counteracts this effect overnight, recovering part of the lost module performance and extending the lifespan of the whole installation without any extra hardware.
Can NEP-KW inverters be installed in coastal or heavy industrial environments?
Yes, NEP-KW inverters feature a Type 4X/C5 rated enclosure for ingress protection and corrosion resistance, shielding against dust, rain, icing, and aggressive salt-laden or industrial air. This makes them suitable for rooftop installations on warehouses, industrial facilities, and utility-scale PV farms located near the coast, without risking corrosion of internal electronics.
What does the 150% DC/AC oversizing ratio on NEP-KW inverters mean, and what are its benefits?
A 150% DC/AC ratio means up to 50% more PV module power can be connected than the inverter's rated AC output. This lets designers install more panels per inverter, make better use of available roof area, and reduce the total number of inverters needed - ultimately lowering the LCOE (levelized cost of energy) in large commercial installations.
Can aluminum cables be used with NEP NEPTUNE NEP-KW inverters instead of copper?
Yes, the NEP-KW series is designed with terminals that support aluminum conductors, which cost less than copper. This matters on large commercial and industrial projects where long cable runs drive up material costs - using aluminum lets installers cut overall system budget without compromising electrical safety.