Skip to main content

Megarevo R16KLNA

16 kW Hybrid Single-phase Battery-ready
Datasheet PDF
Rated AC (kW)
16.00
Typical for its class
Euro eff. (%)
96.2
Weak · bottom 1%
MPPT
4
Strong · top 6%
Max DC (V)
500
Weak · bottom 3%
Weight (kg)
56.0
Weak · 18.0 kg above median
Warranty (yrs)
-
Not published

The Megarevo R-KLNA series is a line of split-phase hybrid inverters built for the North American residential market and homes with higher power demands. What sets it apart is full support for unbalanced loads, letting the unit freely power loads distributed unevenly across the two legs of a split-phase system - a common scenario in US and Canadian homes. The inverters also support building three-phase systems by combining multiple units, making the series a scalable choice for both residential and small commercial sites. Thanks to its 200A pass-through rating, the R-KLNA line allows retrofitting existing PV installations without costly panel upgrades, operating in both on-grid and off-grid modes with AC-coupled solar input. A key advantage is independent grid and generator connections, with the ability to charge the battery from a diesel generator - a feature valued where grid power is unreliable. The units feature four independent MPPT trackers, giving installers flexibility when designing PV strings with different orientations or shading conditions. The IP65/NEMA 3R enclosure rating allows outdoor installation, while the touch panel and RS485/CAN/Wi-Fi/4G connectivity simplify remote monitoring. It's a solid platform for installers seeking a reliable, flexible energy storage solution for homes and small businesses.

Ranking

623 inverters from 12 to 30 kW
Metric This inverter Median Position in class Rank in class
European efficiency 96.2% 98.0% Weak · bottom 1% 459
MPPT trackers 4 2 Strong · top 6% 1
Max DC input voltage 500 V 1000 V Weak · bottom 3% 572
Weight per kW 3.5 1.8 Weak · bottom 7% 556
Warranty - 5 yrs Not published -
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 16 kW Continuous output
Max apparent power 17.60 kVA
Phases Single-phase
Nominal AC voltage 240 V (110~120)/(220~240V) split phase, 240V single phase
Max AC current 73.3 A
Grid frequency 60 Hz Range 55-65Hz
Power factor 0.8 leading ~ 0.8 lagging
Harmonic distortion (THD) 3.0 %
Max DC input power 24.00 kW DC/AC ratio 1.50
Max DC voltage 500 V Caps the string length
MPPT voltage range 120 to 500 V
MPPT trackers 4
European efficiency 96.2 % Weighted across part loads
Max efficiency 96.5 % Best single operating point
Battery port Yes
Battery voltage 40-58V
Dimensions 900 × 495 × 260 mm Height × width × depth
Weight 56.0 kg 3.5 kg per kW
Enclosure IP65 / NEMA 3R
Cooling forced-air
Noise 57 dB
Operating temperature -25 to 60 °C
Max humidity 95 %
Max altitude 4000 m
Interfaces Wi-FiDisplay
Protocols RS485CAN4G (optional)Wi-Fi
Protection AFCI
Certifications UL1741UL1741SA&SBUL1699BCSA-C22.2 NO.107.1-01RSD (NEC690.5, 11, 12)FCC Part 15 Class BIEEE 1547IEEE 2030.5HECO Rule 14HCA Rule 21 Phase I, II, IIICECCSIPSRD2.0SGIPOGPeNOMCalifornia Prob65

Pros and cons

5 positive · 2 caution
What owners get
Full support for unbalanced loads

The inverter freely splits power between the two 120/240V legs without requiring load balancing, a configuration typical of single-family homes in the US and Canada and less commonly addressed by inverters designed primarily for the European market.

Four independent MPPT trackers

Technical documentation confirms 4 MPPT inputs (voltage range approx. 120-500V), allowing PV strings with different orientation and shading profiles to be designed without yield loss - an advantage over competing 2-MPPT models in this power class.

200A pass-through current simplifies retrofits

This feature allows the inverter to be connected in parallel with the existing meter without upgrading the main service panel, a change that typically costs $2,000-$4,000 in the US - a tangible installation cost reduction for retrofit projects.

Independent grid and generator inputs with diesel charging

The ability to charge the battery from a diesel generator via a separate AC input from the grid increases system resilience during outages - a valued feature in rural areas with unstable grid power.

UL1741/IEEE1547 certification and IP65/NEMA 3R enclosure

Compliance with UL1741:2021 and IEEE1547.1 confirms grid-interconnection approval in North America, and the IP65/NEMA 3R enclosure rating allows outdoor installation without additional weatherproofing.

Trade-offs
Lower brand recognition in the Tier-1 segment

Megarevo has a shorter track record in the North American market than leading hybrid inverter brands (e.g. Sol-Ark, Schneider Electric, SMA), which for a niche-market product can mean slower access to spare parts and local technical support.

Low-voltage (48V) architecture limits storage scalability

At 10-16kVA power levels, a 48V battery architecture requires larger-gauge cables and incurs higher current losses than hybrid inverters paired with high-voltage storage (e.g. 400V), increasing BoS cost for larger installations.

Alternatives

All Megarevo inverters
Inverter Power Euro eff. MPPT Weight Difference
Megarevo R16KLNA 16 kW 96.2% 4 56.0 kg You are here
H2-16K-LT2 16 kW 98.0% 2 53.0 kg +1.8 pp efficiency, -2 MPPT, 3.0 kg lighter
HESP48160SHD3 16 kW 97.5% 2 49.5 kg +1.3 pp efficiency, -2 MPPT, 6.5 kg lighter
HESP48160SH3 16 kW 97.2% 3 59.5 kg +1.0 pp efficiency, -1 MPPT, 3.5 kg heavier
S6-EH1P16K03-NV-YD-L 16 kW 97.0% 3 55.5 kg +0.8 pp efficiency, -1 MPPT
SUN-16K-SG05LP3-EU-SM2 16 kW 97.0% 2 51.9 kg +0.8 pp efficiency, -2 MPPT, 4.1 kg lighter
HESP48160S340-H 16 kW 97.0% 3 64.7 kg +0.8 pp efficiency, -1 MPPT, 8.7 kg heavier
SUN-16K-SG01LP1-EU 16 kW 96.5% - 48.5 kg 7.5 kg lighter
SUN-16K-SG01LP1-EU-AM3-P 16 kW 96.5% 3 54.1 kg -1 MPPT, 1.9 kg lighter

About the R-KLNA series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

How does the Megarevo R-KLNA series differ from standard hybrid inverters sold in Europe?
R-KLNA is a split-phase hybrid inverter designed specifically for the North American market, where residential power is split across two 120V phases. The key difference is full support for unbalanced loads, meaning the unit handles loads distributed unevenly between phases - a common scenario in US and Canadian single-family homes, but rarely required in European installations.
Can the Megarevo R-KLNA inverter be used to build a three-phase system?
Yes, the R-KLNA series supports three-phase system configurations by combining multiple units into one coordinated setup. This makes it a scalable solution suited not only for single-family homes but also for small commercial sites that require more capacity than a single split-phase inverter can provide.
Does installing an R-KLNA inverter require replacing the existing electrical panel?
Not necessarily. R-KLNA inverters feature a 200A pass-through current rating, which allows upgrading an existing PV installation without the costly replacement of the main service panel. This is a significant advantage when adding battery storage to a home where the electrical system was originally designed for different loads.
Can the Megarevo R-KLNA inverter charge the battery from a generator during a grid outage?
Yes, the R-KLNA has independent grid and generator connections, along with the ability to charge the battery using power from a diesel generator. This feature is especially valuable in regions with unstable grid power or in homes without reliable grid access, where a generator serves as a backup power source.
How many PV strings with different orientations can be connected to the R-KLNA inverter?
R-KLNA inverters are equipped with four independent MPPT trackers, allowing you to connect strings with different orientations, tilt angles, or shading conditions, with each optimized separately. This flexibility is useful for roofs with complex geometry or partial shading that varies throughout the day.
Can the Megarevo R-KLNA inverter be installed outdoors?
Yes, the enclosure carries an IP65/NEMA 3R rating, allowing safe outdoor installation protected against rain and dust. The unit also includes a touchscreen panel and RS485, CAN, Wi-Fi, and 4G communication options, enabling remote monitoring of system performance without needing to be physically present at the inverter.