Skip to main content
KOSTAL PIKO CI 100

KOSTAL PIKO CI 100

100 kW Grid-tie Three-phase
Datasheet PDF
Rated AC (kW)
100.00
Strong · top 8%
Euro eff. (%)
97.8
Weak · bottom 17%
MPPT
8
Strong · top 17%
Max DC (V)
1100
Typical · median 1100 V
Weight (kg)
93.0
Typical · median 75.0 kg
Warranty (yrs)
5
Typical · median 5 yrs

The KOSTAL PIKO CI series is a lineup of three-phase inverters designed for commercial, industrial, and larger agricultural installations, offered across several power classes that let installers match the device to project scale without stacking multiple smaller units. The standout advantage of this line is its high conversion efficiency combined with a compact footprint, making it easier to install in space-constrained settings typical of production halls or farm buildings. These units feature integrated feed-in power management that complies with grid operator requirements, enabling PV energy sales without additional external components. Another key element is the integrated AC switch, which eliminates the need for separate grid disconnectors and reduces overall BoS costs for the installation. Setup and commissioning are streamlined through a dedicated mobile app, while ongoing system monitoring is handled by the manufacturer's free tools available for smartphones and PCs. The newer generation within the series, the PIKO CI G2, builds on these strengths with arc fault detection (AFCI), replaceable Type 2 surge protection, and a rugged IP66-rated enclosure, raising the bar for safety and durability in demanding operating conditions. This makes it a solid choice for installers and investors seeking reliable, scalable commercial-grade equipment from a reputable German manufacturer.

Ranking

552 inverters from 30 to 100 kW
Metric This inverter Median Position in class Rank in class
European efficiency 97.8% 98.2% Weak · bottom 17% 334
MPPT trackers 8 4 Strong · top 17% 45
Max DC input voltage 1100 V 1100 V Typical 12
Weight per kW 0.9 1.2 Typical 149
Warranty 5 yrs 5 yrs Typical 45
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Price offers

1 from shops we track
Shop Country Price Per kW Stock Offer updated Link to shop
www.frexolaire.com France 9 525.60 € incl. VAT 95.26 €/kW In stock 10h ago Visit shop

Specifications

Open datasheet PDF
Rated AC power 100 kW Continuous output
Max apparent power 111.00 kVA
Phases Three-phase
Nominal AC voltage 400 V 322-520
Max AC current 168.8 A
Grid frequency 50 Hz Range 45-55
Power factor 0.8 leading - 0.8 lagging
Harmonic distortion (THD) 3.0 %
Max DC input power 150.00 kW DC/AC ratio 1.50
Max DC voltage 1100 V Caps the string length
MPPT voltage range 540 to 800 V
Start-up voltage 250 V
MPPT trackers 8
Max input current per MPPT 40.0 A Must exceed the panel's Imp
Max short-circuit current per MPPT 50.0 A Must exceed the panel's Isc
European efficiency 97.8 % Weighted across part loads
Max efficiency 98.3 % Best single operating point
Dimensions 678 × 936 × 365 mm Height × width × depth
Weight 93.0 kg 0.9 kg per kW
Enclosure IP66
Cooling forced-air
Noise 65 dB
Operating temperature -25 to 60 °C
Max humidity 100 %
Max altitude 4000 m
Interfaces Wi-FiEthernetBluetoothDisplay
Protocols RS485Ethernet LAN TCP/IP (RJ45)WiFiBluetooth
Protection AFCIDC switchSurge protection
Warranty 5 years Standard manufacturer cover
Certifications EN62109-1EN62109-2IEC 62920VDE-AR-N 4105:2018VDE V 0124-100PO12.2RD 244:2019UNE 217001EN 50549-1EN 50549-2CEI0-16 2019CEI0-21 2019UK G99/1-4 LVIRR-DCC MV 2015IEC61727IEC62116

Pros and cons

5 positive · 2 caution
What owners get
High conversion efficiency

PIKO CI units reach a peak efficiency of 98.2-98.3% and a European efficiency of 97.9-98.1%, with 99.9% MPP tracking accuracy limiting energy losses even under the variable irradiance typical of large commercial installations.

Integrated AC disconnect switch

A built-in grid disconnect switch removes the need for a separate external AC switch, meaningfully reducing BoS costs and installation time compared to competing commercial inverters that require separate switchgear.

Built-in active power limiting

Integrated active power management complies with grid operator (DSO) requirements, allowing power feed-in without additional external controllers - a significant advantage for agricultural and industrial installations.

AFCI, Type 2 SPD, and IP66 on the G2 generation

The newer PIKO CI G2 generation adds arc-fault circuit interruption (AFCI), a replaceable Type 2 surge protection device, and an IP66-rated enclosure, raising fire safety and environmental durability compared to the base series.

Free monitoring and simple commissioning

Setup and configuration run through the manufacturer's dedicated mobile app, while free monitoring tools for smartphones and computers track system performance without additional licensing fees.

Trade-offs
Base warranty limited to 5 years

The standard KOSTAL Smart Warranty covers only 5 years, with a paid 10-year extension available after registration in the manufacturer's online shop. This base coverage is shorter than that of some tier-1 commercial inverter competitors, which offer longer standard warranties or more favorable extension terms for installations designed for a 20-25-year lifespan.

G1/G2 generation fragmentation

Safety features such as AFCI, replaceable Type 2 surge protection, and IP66 housing are only available on the newer PIKO CI G2 generation, while the base series models lack these protections - requiring installers and investors to carefully verify which generation they are actually purchasing.

Alternatives

All KOSTAL inverters
Inverter Power Euro eff. MPPT Weight Difference
KOSTAL PIKO CI 100 100 kW 97.8% 8 93.0 kg You are here
100 NX3 M8 100 kW 98.8% - - +1.0 pp efficiency
SUN2000-100KTL-M2 100 kW 98.6% 10 93.0 kg +0.8 pp efficiency, +2 MPPT
SUN2000-100KTL-M1 (@480 V) 100 kW 98.6% 10 90.0 kg +0.8 pp efficiency, +2 MPPT, 3.0 kg lighter
M100_210 100 kW 98.6% 1 67.0 kg +0.8 pp efficiency, -7 MPPT, 26.0 kg lighter
SG110CX 100 kW 98.5% 9 89.0 kg +0.7 pp efficiency, +1 MPPT, 4.0 kg lighter
Sunny Highpower PEAK3 SHP 100-21 100 kW 98.5% 1 99.0 kg +0.7 pp efficiency, -7 MPPT, 6.0 kg heavier
Sunny Highpower Storage SHPS 100-21 100 kW 98.5% - 99.0 kg +0.7 pp efficiency, 6.0 kg heavier
Solis-100K-5G 100 kW 98.5% 9 82.0 kg +0.7 pp efficiency, +1 MPPT, 11.0 kg lighter

About the PIKO CI series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

What power classes are available in the KOSTAL PIKO CI series and how do I choose the right model?
The PIKO CI series offers three-phase inverters in power classes including 30 kW and 50 kW (G2 models), with maximum PV input up to 45 kWp and 75 kWp respectively. The choice depends on system size - for production halls or agricultural sites, a single properly sized unit avoids combining multiple smaller inverters, simplifying design and maintenance.
What is the difference between PIKO CI G2 and the first-generation PIKO CI?
The G2 generation adds arc fault circuit interruption (AFCI), replaceable type 2 surge protection, and a rugged IP66-rated enclosure, improving fire safety and durability in harsh environments such as industrial halls or outdoor installations. The first generation lacked this level of protection, though it shared the same compact design and high efficiency approach.
Do I need a separate AC disconnect switch with PIKO CI inverters?
No, PIKO CI includes an integrated AC switch that replaces the external grid disconnector required by some utilities. This lowers the BoS cost of the installation since installers don't need to purchase and mount an additional disconnect box, a meaningful difference versus many competing commercial inverters.
How does power curtailment management work in PIKO CI, and is it sufficient for grid feed-in?
PIKO CI inverters have built-in power curtailment functions compliant with grid operator requirements (e.g., active power reduction), so energy export happens without additional external controllers. This simplifies grid connection approval and shortens project commissioning time.
What warranty does the KOSTAL PIKO CI series come with?
The standard Smart Warranty covers 5 years from online registration, extendable up to 10 years for an additional fee. For commercial installations, where downtime causes financial losses, extending the warranty is often recommended given the intensive duty cycle these inverters handle.
Does PIKO CI require a special app for setup and monitoring?
Yes, commissioning and configuration are done through a dedicated KOSTAL mobile app, and ongoing energy production monitoring is handled by the manufacturer's free tools for smartphones and computers. The inverters include built-in Wi-Fi, Ethernet LAN, and RS485 ports, enabling integration with building management or solar farm monitoring systems.