The Powador 02 series is a family of single-phase KACO string inverters built for installations where a transformer-based design is a requirement, not a preference. Thanks to galvanic isolation via a high-frequency transformer, these units excel precisely where transformerless inverters fall short due to safety codes or module characteristics. The standout strength of this line is its optimal suitability for thin-film modules - KACO offers a dedicated PV generator earthing kit for the series, essential for the long-term durability of thin-film cells, while the inverter continuously monitors and displays the generator's earthing status. Installation has been pared down to the essentials: every communication interface (RS485, S0, fault-signalling relay) sits on a single circuit board, and MC4 connectors let installers handle the DC wiring safely from outside the housing without opening the unit. On top of that, a wide MPP voltage range gives system designers real flexibility when configuring strings, even for complex layouts. The series suits installers working in markets with strict grid-connection codes and projects involving modules that require earthing - settings where straightforward servicing and regulatory compliance matter more than chasing peak efficiency numbers.
Ranking
Specifications
Pros and cons
A built-in high-frequency transformer (17 kHz clock) provides full galvanic DC/AC isolation, meeting grid-code requirements in markets that mandate transformer separation and supporting module technologies that cannot run on transformerless inverters, unlike most of today's string inverters.
The series offers a factory-supplied PV generator earthing kit with continuous earthing-status monitoring on the display - a feature rarely offered by competitors and critical for the long-term durability of thin-film modules that require positive or negative-pole grounding.
All communication interfaces (RS485, S0, fault-signal relay) are consolidated on a single board, and external MC4 connectors allow DC-side wiring without opening the enclosure, reducing installation time and field-wiring errors.
An extended MPP voltage window, per KACO's catalog data for the 2002-6002 series, gives system designers flexibility for string configuration even with partial shading or mixed roof orientations.
KACO new energy has operated in the energy sector since 1914, reflected in the series' mechanical and electrical build quality - the company was among the first to bring transformer-based string inverters tailored to thin-film modules to market.
The Powador 02 series (2002-6002) is no longer manufactured or actively supported - KACO's repowering program explicitly recommends replacing older Powador units with newer blueplanet NX3 inverters, meaning spare parts and warranty service are increasingly hard to obtain.
Maximum efficiency of up to 96% (per catalog data) is well below the 97.5-98.5%+ typical of today's tier-1 transformerless string inverters, translating into a measurably lower annual energy yield for a comparable installation.
The standard factory warranty was 10 years, while current string inverters (e.g., Huawei, SMA, Fronius) ship with 10-15 years base coverage extendable to 20-25 years - competitive at launch, but a notable limitation today.
The series includes only single-phase units ranging from roughly 1.65 kVA to 5.0 kVA, ruling it out for larger commercial installations that require three-phase inverters or higher power ranges.
Alternatives
About the Powador 02 series
These answers cover the whole series. Where a figure differs, the specification above is this model's own.