Skip to main content
KACO gridsave 137 TL3-S GEN2

KACO gridsave 137 TL3-S GEN2

137 kW Hybrid Three-phase Battery-ready
Datasheet PDF
Rated AC (kW)
137.00
Typical for its class
Euro eff. (%)
-
Not published
MPPT
-
Not published
Max DC (V)
1450
Typical · median 1100 V
Weight (kg)
80.0
Typical · median 99.0 kg
Warranty (yrs)
-
Not published

The blueplanet gridsave GEN2 series is the second generation of KACO's industrial battery inverters, built for commercial and industrial energy storage installations. The key upgrade over the previous generation is an extended DC voltage window up to 1450 V, giving system designers greater flexibility in battery configuration while reducing losses on the DC side. These units operate as a bidirectional battery inverter handling both charging and discharging in grid-following mode, making them a natural fit for peak shaving, grid balancing, and integration with photovoltaic systems. Digital security has been strengthened through enhanced cybersecurity for the Modbus TCP/Sunspec-based communication, which matters when managing a fleet of storage assets remotely. The transformerless design and IP66-rated enclosure allow outdoor installation in demanding environments, while three hardware variants, M, L, and XL, differentiate the DC protection scope (fuse, contactor, pre-charge circuit) to match project requirements. The series also follows a future-proof certification roadmap aligned with evolving grid codes, helping investors plan long-term deployments without the risk of the hardware becoming quickly outdated.

Ranking

238 inverters from 100 to 500 kW
Metric This inverter Median Position in class Rank in class
European efficiency - 98.5% Not published -
MPPT trackers - 8 Not published -
Max DC input voltage 1450 V 1100 V Typical 110
Weight per kW 0.6 0.7 Typical 91
Warranty - 5 yrs Not published -
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 137 kW Continuous output
Max apparent power 137.00 kVA
Phases Three-phase
Max AC current 132.3 A
Grid frequency 50 Hz Range 45-65 Hz
Power factor 0 – 100% Smax / 0.30 ind. – 0.30 cap.
Harmonic distortion (THD) 3.0 %
Max DC voltage 1450 V Caps the string length
Max input current per MPPT 145.0 A Must exceed the panel's Imp
Max short-circuit current per MPPT 300.0 A Must exceed the panel's Isc
Max efficiency 98.9 % Best single operating point
Battery port Yes
Battery voltage 668-1450 V
Max charge current 145.0 A
Max discharge current 145.0 A
Dimensions 699 × 719 × 450 mm Height × width × depth
Weight 80.0 kg 0.6 kg per kW
Enclosure IP66 / NEMA 4X
Cooling forced-air
Noise 60 dB
Operating temperature -20 to 60 °C
Max humidity 100 %
Max altitude 3000 m
Interfaces EthernetDisplay
Protocols TCP/IPModbus TCPEthernetUSB
Protection Surge protection
Certifications IEC 62477:2022EN 62109-1EN 62109-2

Pros and cons

5 positive · 1 caution
What owners get
Extended DC voltage window up to 1,450 V

GEN2 raises the maximum DC voltage to 1,450 V (versus roughly 1,315 V on the prior TL3-S generation), enabling longer battery strings, lower conduction losses, and simpler configuration for commercial/industrial storage systems.

High efficiency through SiC technology

SiC-based power electronics push maximum efficiency to 98.9%, a clear improvement over GEN1 (around 98.5-98.7% on the 92-137 kW models), translating into lower round-trip energy losses.

Bidirectional grid-following operation

The inverter handles simultaneous charging and discharging in real time, making it directly applicable to peak shaving, energy arbitrage, and grid balancing without additional management hardware.

Reinforced cybersecurity for Modbus TCP/Sunspec

For remote battery storage fleet management, strengthened communication security reduces the risk of unauthorized access to operating parameters, which is increasingly relevant under tightening EU cybersecurity requirements (e.g., NIS2).

Three M/L/XL variants tailored to project needs

Differentiated DC protection levels (fuse, contactor, pre-charge circuit) across three variants let investors choose the protection level needed without paying for unused features in simpler projects.

Trade-offs
Limited single-unit power vs. utility-scale rivals

Maximum output per unit in the 92-137 kVA class is significantly lower than utility-scale competitors such as Sungrow (e.g., SC2500UD-MV at ~2.5 MVA per block), requiring multiple KACO units in parallel for large storage projects and increasing BoS complexity and cost.

Alternatives

All KACO inverters
Inverter Power Euro eff. MPPT Weight Difference
KACO gridsave 137 TL3-S GEN2 137 kW - - 80.0 kg You are here
125M1-HYB 125 kW 98.3% - 108.0 kg -12.0 kW, 28.0 kg heavier
125M1-HYA 125 kW 98.3% - 95.0 kg -12.0 kW, 15.0 kg heavier
SUN-125K-SG02HP3-EU-GM10 125 kW 98.1% 10 161.7 kg -12.0 kW, 81.7 kg heavier
H3-125-Plus 125 kW 98.1% - 120.0 kg -12.0 kW, 40.0 kg heavier
P3-125-Plus 125 kW 98.1% - 120.0 kg -12.0 kW, 40.0 kg heavier
HYX-H125K-ET 125 kW 98.0% - 95.0 kg -12.0 kW, 15.0 kg heavier
CH3-125K-T8 125 kW 97.5% 2 145.0 kg -12.0 kW, 65.0 kg heavier
S6-EH3P125K10-NV-YD-H 125 kW 97.2% 10 170.0 kg -12.0 kW, 90.0 kg heavier

About the blueplanet gridsave GEN2 series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

How does the blueplanet gridsave GEN2 differ from the previous generation of KACO battery inverters?
The key change is the extended DC voltage window up to 1450 V, which allows more flexible battery string configurations and reduces losses during power transfer. KACO also strengthened cybersecurity for Modbus TCP/Sunspec communication, which matters for remote fleet management of energy storage systems. This is a substantial upgrade for commercial and industrial BESS projects, not just a cosmetic rebrand.
What is the difference between the M, L, and XL variants of the blueplanet gridsave GEN2 series?
The M, L, and XL variants differ in the scope of DC-side protection, such as fuse, contactor, and pre-charge circuit. A higher-tier variant offers more comprehensive protection for the battery installation, which matters for larger storage systems or projects with stricter safety requirements. The right choice depends on project scale and local codes, so it's worth consulting an integrator.
Can the blueplanet gridsave GEN2 inverter be installed outdoors?
Yes, the units use a transformerless design with an IP66-rated enclosure, allowing outdoor installation even in harsh environmental conditions, such as containerized energy storage systems. This eliminates the need for a dedicated technical room, reducing overall installation costs.
What applications is the blueplanet gridsave GEN2 inverter suited for - peak shaving or PV integration?
The inverter operates as a bidirectional battery inverter handling simultaneous charging and discharging in grid-following mode, making it suitable for peak shaving, grid balancing, and integration with PV systems. It's a versatile solution for commercial and industrial energy storage, removing the need for a separate dedicated PV inverter.
Is the blueplanet gridsave GEN2 compliant with current and upcoming grid codes?
Yes, the series follows a grid certification roadmap aligned with evolving regulations, meaning the units are prepared for updates to interconnection standards across different markets. This lets investors plan long-term deployments without the risk of the hardware quickly becoming non-compliant with new utility requirements.
How secure is remote communication for the blueplanet gridsave GEN2 when managing a fleet of storage systems?
The second-generation gridsave introduces enhanced cybersecurity for Modbus TCP/Sunspec communication. This is especially important for remote monitoring and management of multiple energy storage systems simultaneously, where the risk of unauthorized access is higher than with a single local installation.