Skip to main content

INVT XD10KTL

10 kW Hybrid Single-phase Battery-ready
Datasheet PDF
Rated AC (kW)
10.00
Typical for its class
Euro eff. (%)
97.5
Typical · median 97.5%
MPPT
2
Typical · median 2
Max DC (V)
600
Typical · median 800 V
Weight (kg)
32.0
Typical · median 27.0 kg
Warranty (yrs)
-
Not published

The XD7-10KTL series is a line of single-phase hybrid inverters from INVT built for residential installations where maximizing solar energy harvest goes hand in hand with reliable backup power during grid outages. Thanks to a dual MPPT tracker with 160% DC oversizing, the unit handles uneven panel irradiance and gives installers more flexibility in system design without sacrificing energy yield. A standout feature of this series is 200% peak output power in EPS mode, meaning the inverter can start and power high-inrush appliances during a power cut with a switchover that is practically seamless. The series also offers full compatibility with lithium and lead-acid batteries, making it easy to integrate with an existing energy storage system or choose a more budget-friendly option at setup. In addition, an IP66 protection rating allows outdoor installation without needing extra enclosures, while the optional AFCI function and smart I-V curve diagnostics boost system safety and simplify remote servicing. This makes the XD7-10KTL series a solid choice for installers looking for a reliable, versatile inverter for single-family homes.

Ranking

839 inverters from 6 to 12 kW
Metric This inverter Median Position in class Rank in class
European efficiency 97.5% 97.5% Typical 268
MPPT trackers 2 2 Typical 145
Max DC input voltage 600 V 800 V Typical 409
Weight per kW 3.2 3.0 Typical 468
Warranty - 5 yrs Not published -
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 10 kW Continuous output
Max AC power 11.00 kW Short-term output above the rating
Max apparent power 11.00 kVA
Phases Single-phase
Nominal AC voltage 230 V
Max AC current 50.0 A
Grid frequency 50 Hz Range 50Hz / 60Hz
Power factor 0.8 leading ~ 0.8 lagging
Harmonic distortion (THD) 3.0 %
Max DC input power 15.00 kW DC/AC ratio 1.50
Max DC voltage 600 V Caps the string length
MPPT voltage range 100 to 550 V
Start-up voltage 100 V
MPPT trackers 2 2 strings each
Max input current per MPPT 40.0 A Must exceed the panel's Imp
European efficiency 97.5 % Weighted across part loads
Max efficiency 98.0 % Best single operating point
Battery port Yes
Battery voltage 40V ~ 60V
Max charge current 175.0 A
Max discharge current 175.0 A
Backup power 7.70 kW Output during a grid outage
Grid-forming Yes
Dimensions 534 × 440 × 240 mm Height × width × depth
Weight 32.0 kg 3.2 kg per kW
Enclosure IP66
Cooling forced-air
Operating temperature -30 to 60 °C
Max humidity 100 %
Max altitude 4000 m
Interfaces Wi-FiBluetoothDisplay
Protocols RS485CANWiFi4GBluetooth
Protection AFCISurge protection

Pros and cons

5 positive · 2 caution
What owners get
Dual MPPT with 160% DC oversizing

Two independent MPPT trackers accepting up to 160% DC-to-AC power ratio allow flexible system design for roofs with uneven shading or mismatched string orientation without sacrificing energy yield.

200% peak power in EPS mode

A 2x surge capability in off-grid (EPS) mode enables seamless starting of high-inrush loads (pumps, refrigerators, compressors) during grid outages, outperforming inverters limited to 100-150% EPS overload.

Compatible with Li-ion and lead-acid batteries

Support for both lithium batteries and cheaper lead-acid batteries gives installers flexibility to size storage for budget-conscious projects or integrate with an existing BMS.

IP66 protection rating

The IP66 enclosure allows outdoor installation (garage wall, exterior facade) without an additional protective housing, cutting installation costs compared to IP65/IP54 units that require indoor mounting.

AFCI and I-V curve diagnostics

Optional arc-fault circuit interruption (AFCI) combined with smart I-V curve diagnostics speeds up remote fault detection on PV strings, reducing service time and improving fire safety.

Trade-offs
Standard warranty only 5 years

Manufacturer documentation lists a base warranty of 5 years, while some tier-1 hybrid inverter competitors (e.g., Huawei, GoodWe) offer 10 years as standard. Extending to 10/15/20 years with INVT requires an additional purchase and registration within 12 months of delivery.

Single-phase only, capped at 10 kW

The XD7-10KTL series is limited to single-phase 7-10 kW models, ruling it out for larger single-family homes or installations requiring balanced three-phase loads without switching to a different INVT product line.

Alternatives

All INVT inverters
Inverter Power Euro eff. MPPT Weight Difference
INVT XD10KTL 10 kW 97.5% 2 32.0 kg You are here
SE10000H 10 kW 99.0% - 19.6 kg +1.5 pp efficiency, 12.4 kg lighter
SigenStor Neo EC 10.0 TP 10 kW 98.7% - 30.0 kg +1.2 pp efficiency, 2.0 kg lighter
Sigen Hybrid 10.0 TP2 10 kW 98.5% 2 19.5 kg +1.0 pp efficiency, 12.5 kg lighter
HYX-H10K-HSA2 10 kW 98.2% - 38.0 kg +0.7 pp efficiency, 6.0 kg heavier
HYX-H10K-HT 10 kW 98.2% 2 34.0 kg +0.7 pp efficiency, 2.0 kg heavier
MOD 10KTL3-XH 10 kW 98.1% 2 14.0 kg +0.6 pp efficiency, 18.0 kg lighter
MOD 10KTL3-HU 10 kW 98.1% 3 20.0 kg +0.6 pp efficiency, +1 MPPT, 12.0 kg lighter
SUN2000-10KTL-M1 10 kW 98.1% 2 17.0 kg +0.6 pp efficiency, 15.0 kg lighter

About the XD7-10KTL series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

What does 160% DC oversizing mean on the INVT XD7-10KTL and what's the real-world benefit?
It means each MPPT tracker can accept up to 160% of its rated input power in connected PV modules. This lets installers design a larger PV array than the inverter's AC power would otherwise suggest, boosting energy yield, especially under uneven irradiance, partial shading, or arrays split across two roof planes.
What does 200% peak power in EPS mode on the XD7-10KTL mean and when does it matter?
In EPS, or backup power mode, the inverter can briefly deliver twice its rated power. This lets it start high-surge-current loads, such as submersible pumps, refrigerators, or compressors, without tripping the backup circuit when the grid goes down.
Can the XD7-10KTL be paired with lead-acid batteries, or only lithium?
The XD7-10KTL series is compatible with both battery chemistries. You can connect a lithium battery with BMS communication or a lower-cost lead-acid battery, which is a convenient option for a starter system or when expanding an existing energy storage setup.
Can the INVT XD7-10KTL inverter be installed outdoors?
Yes, the unit carries an IP66 rating, meaning full dust protection and resistance to powerful water jets from any direction. It can be safely mounted on an exterior wall, in an unheated garage, or under a carport without needing a separate protective enclosure.
What fire-safety protections does the XD7-10KTL offer?
The optional AFCI function detects dangerous arc faults on the DC side, which can occur from damaged connectors or worn cabling, and automatically shuts down the inverter to prevent fire. Built-in I-V curve diagnostics also continuously monitor PV module performance, helping flag faults remotely without a rooftop service visit.
What type of single-phase installations is the INVT XD7-10KTL series best suited for?
This series is built for single-phase residential homes that want to maximize self-consumption of solar energy while having backup power in case of a grid outage. Thanks to flexible MPPT design and high EPS power, it suits both new installations paired with battery storage and upgrades to existing PV systems.