HYXiPower HYX-S50K-T

50 kW Grid-tie Three-phase
Datasheet PDF
Rated AC (kW)
50.00
Typical for its class
Euro eff. (%)
98.1
Typical · median 98.2%
MPPT
-
Not published
Max DC (V)
1100
Typical · median 1100 V
Weight (kg)
44.0
Strong · 31.0 kg below median
Warranty (yrs)
-
Not published

The HYX-S-T series is a line of three-phase string inverters that combine precise fault diagnostics with generous DC input headroom. Their standout strength is module-level monitoring paired with intelligent IV diagnostics, so a single panel fault never goes unnoticed and pinpointing it takes moments instead of hours of inspecting the whole string. A design built around 40A input capability lets these inverters pair easily with modern high-power modules, while 160% PV oversizing allows installers to make full use of array potential even with a limited AC output rating. Safety comes from an IP66-rated enclosure resistant to dust and moisture, along with an AFCI system that detects electrical arcing within a 300-meter radius and triggers a rapid shutdown. A compact, lightweight housing and plug-and-play installation significantly cut setup time, while configuration and real-time energy monitoring run through a mobile app. This is a solution for installers and owners of larger homes or small commercial sites who expect high efficiency, PV optimizer compatibility, and genuine control over their solar installation at every stage of operation.

Ranking

552 inverters from 30 to 100 kW
Metric This inverter Median Position in class Rank in class
European efficiency 98.1% 98.2% Typical 223
MPPT trackers - 4 Not published -
Max DC input voltage 1100 V 1100 V Typical 12
Weight per kW 0.9 1.2 Strong · top 23% 118
Warranty - 5 yrs Not published -
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 50 kW Continuous output
Max apparent power 55.00 kVA
Phases Three-phase
Nominal AC voltage 400 V 220/380V, 230/400V
Max AC current 83.6 A
Grid frequency 50 Hz Range 50/60Hz
Power factor 0.8 leading...0.8 lagging
Harmonic distortion (THD) 3.0 %
Max DC input power 80.00 kW DC/AC ratio 1.60
Max DC voltage 1100 V Caps the string length
MPPT voltage range 140 to 1000 V
Start-up voltage 160 V
Max input current per MPPT 40.0 A Must exceed the panel's Imp
Max short-circuit current per MPPT 50.0 A Must exceed the panel's Isc
European efficiency 98.1 % Weighted across part loads
Max efficiency 98.6 % Best single operating point
Dimensions 460 × 615 × 268 mm Height × width × depth
Weight 44.0 kg 0.9 kg per kW
Enclosure IP66
Cooling forced-air
Operating temperature -30 to 60 °C
Max humidity 100 %
Max altitude 4000 m
Interfaces Wi-FiDisplay
Protocols RS4854GWIFIHPLC
Protection AFCIDC switchSurge protection

Pros and cons

5 positive · 2 caution
What owners get
Module-level IV curve diagnostics

The inverter provides per-module monitoring and intelligent IV-curve diagnostics, allowing a single faulty panel to be pinpointed in minutes instead of requiring a multi-hour string-by-string inspection - a real service-time advantage for installers managing fleets of systems.

40A DC input per MPPT

Support for up to 40A input current per MPPT tracker allows direct connection of modern high-power modules (half-cut, TOPCon) without extra string-limiting protection, simplifying system design.

Up to 160% PV oversizing ratio

A DC/AC oversizing ratio of up to 160% exceeds the typical 110-135% offered by many competing string inverters, enabling more PV capacity per unit of AC power - useful where grid connection capacity is limited.

IP66 enclosure and AFCI arc detection

The IP66-rated enclosure supports outdoor installation in harsh weather, and the built-in AFCI system claims arc-fault detection up to 300 m, a wider declared range than many comparable products (roughly 100 m for some competitors).

Plug-and-play install, app-based setup

The compact, lightweight design and plug-and-play installation reduce commissioning time, while full configuration and production monitoring are handled through a mobile app, benefiting both installers and system owners.

Trade-offs
Limited independent verification of specs

The claimed 300 m AFCI arc-detection range and full warranty terms are not confirmed in publicly available manufacturer datasheets, unlike established Tier-1 brands (Huawei, SolaX, SMA) where such parameters are consistently documented and independently lab-tested.

Smaller brand footprint and service network

HYXiPower has a shorter market track record than leading string-inverter manufacturers, which can mean more limited local service coverage, spare-parts availability, and slower warranty response times compared to more established Tier-1 brands.

Inverter Power Euro eff. MPPT Weight Difference
HYXiPower HYX-S50K-T 50 kW 98.1% - 44.0 kg You are here
SUN2000-50KTL-JPM0 50 kW 98.6% 6 71.0 kg +0.5 pp efficiency, 27.0 kg heavier
SUN2000-50KTL-M0 50 kW 98.5% 6 74.0 kg +0.4 pp efficiency, 30.0 kg heavier
Solis-50K-HV 50 kW 98.5% 4 61.0 kg +0.4 pp efficiency, 17.0 kg heavier
BNT050KTL 50 kW 98.5% - 44.0 kg +0.4 pp efficiency
MAX 50KTL3 LV 50 kW 98.4% - 82.0 kg +0.3 pp efficiency, 38.0 kg heavier
SG50CX 50 kW 98.4% - 62.0 kg +0.3 pp efficiency, 18.0 kg heavier
Solis-50K 50 kW 98.4% 4 63.0 kg +0.3 pp efficiency, 19.0 kg heavier
XG50KTR 50 kW 98.4% 4 50.0 kg +0.3 pp efficiency, 6.0 kg heavier

About the HYX-S-T series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

How does module-level monitoring in the HYX-S-T differ from standard string-level diagnostics?
Standard inverters only show total string output, so a single failing panel can go unnoticed for weeks. The HYX-S-T uses IV curve diagnostics to analyze each module's current-voltage characteristics individually, detecting issues like soiling, microcracks, or a defective panel within minutes, without having to physically inspect every module on the roof.
Can the HYX-S-T handle modern high-power, high-current solar panels?
Yes, the HYX-S-T's DC inputs support up to 40A per string, comfortably covering the specs of today's high-power modules, including bifacial and TOPCon panels that produce higher short-circuit currents. There's no need to limit the number of panels per string out of concern for exceeding input limits.
What does the 160% PV oversizing ratio mean in practice?
This is the maximum ratio of installed DC panel capacity to the inverter's AC output. For example, a 10 kW inverter can support up to 16 kWp of panels. This is especially useful for installations with suboptimal orientation or partial shading, where real-world DC output rarely reaches full capacity, boosting annual energy yield without needing a larger inverter.
Is the HYX-S-T safe to install outdoors, such as on a building facade?
Yes, the IP66-rated enclosure effectively protects the electronics from dust and moisture, allowing outdoor installation without an additional canopy. The inverter also includes AFCI arc-fault detection covering a 300-meter DC circuit radius, automatically disconnecting the system if an arc is detected, which significantly improves fire safety.
How does setup and energy production monitoring work with the HYX-S-T inverter?
The inverter is designed for plug-and-play commissioning, with initial setup and ongoing production monitoring handled through a dedicated mobile app. Users get real-time data across the whole system, and if an issue arises with a specific module, the app pinpoints its location, eliminating the need for a service call just for preliminary diagnostics.
Who is the HYX-S-T series best suited for?
The HYX-S-T is a three-phase solution aimed at larger single-family homes and small businesses that need high efficiency and real control over system performance. Its compatibility with power optimizers makes it a good fit for installers working with roofs that have varied sun exposure or partial shading, requiring precise module-level energy management.