Skip to main content
HYXiPower HYX-H110K-ET

HYXiPower HYX-H110K-ET

110 kW Hybrid Three-phase Battery-ready
Datasheet PDF
Rated AC (kW)
110.00
Weak · bottom 9%
Euro eff. (%)
98.0
Weak · bottom 5%
MPPT
-
Not published
Max DC (V)
1100
Typical · median 1100 V
Weight (kg)
95.0
Weak · bottom 11%
Warranty (yrs)
-
Not published

The HYX-H-ET series comprises three-phase hybrid inverters built for commercial and industrial installations, spanning a power range from 50 to 125 kW. These units are engineered for integration with battery storage in a DC-coupled architecture, reducing energy conversion stages and lowering overall PV-ESS system cost in practice. An extensive MPPT section with up to eight independent trackers and AI-driven dynamic MPPT delivers precise maximum power point tracking even under uneven irradiance across strings, boosting energy yield. Built-in PID recovery protects PV modules from potential-induced degradation, extending service life and preserving system performance over time. Safety is reinforced with Type II surge protection on both DC and AC sides, along with optional AFCI arc-fault detection and rapid shutdown. A rugged, compact IP66-rated enclosure with smart air cooling keeps the inverter running reliably in harsh outdoor conditions without sacrificing efficiency. Adaptive three-phase wiring sequencing simplifies installation, while remote monitoring and OTA updates streamline maintenance. This series is built for integrators and investors seeking a high-performance, scalable platform for large commercial projects paired with energy storage.

Ranking

238 inverters from 100 to 500 kW
Metric This inverter Median Position in class Rank in class
European efficiency 98.0% 98.5% Weak · bottom 5% 165
MPPT trackers - 8 Not published -
Max DC input voltage 1100 V 1100 V Typical 113
Weight per kW 0.9 0.7 Weak · bottom 11% 209
Warranty - 5 yrs Not published -
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 110 kW Continuous output
Max apparent power 121.00 kVA
Phases Three-phase
Nominal AC voltage 400 V
Max AC current 183.8 A
Grid frequency 50 Hz Range 50/60Hz
Power factor >0.99 / 0.8 leading...0.8 lagging
Harmonic distortion (THD) 3.0 %
Max DC voltage 1100 V Caps the string length
MPPT voltage range 140 to 1000 V
Start-up voltage 160 V
Max input current per MPPT 40.0 A Must exceed the panel's Imp
Max short-circuit current per MPPT 50.0 A Must exceed the panel's Isc
European efficiency 98.0 % Weighted across part loads
Max efficiency 98.5 % Best single operating point
Battery port Yes
Battery voltage 600-950Vd.c.
Dimensions 760 × 880 × 340 mm Height × width × depth
Weight 95.0 kg 0.9 kg per kW
Enclosure IP66
Cooling forced-air
Operating temperature -30 to 60 °C
Max humidity 100 %
Max altitude 4000 m
Interfaces Wi-FiDisplay
Protocols RS4854GWiFiHPLC
Protection AFCIDC switchSurge protection

Pros and cons

5 positive · 3 caution
What owners get
DC-coupled BESS architecture

DC-coupled integration with energy storage eliminates one energy conversion stage (no extra AC-DC-AC processing), which in practice means higher PV-ESS system efficiency and lower overall installation CAPEX compared to AC-coupled architectures used by some tier-1 competitors.

8-channel MPPT with dynamic tracking

Eight independent MPPT inputs with intelligent dynamic MPPT enable precise handling of uneven shading across panel strings, a significant advantage for large rooftop and industrial installations with complex geometry, where competing products in this power class often offer only 2-4 MPPT trackers.

Built-in PID recovery function

The integrated PID recovery mechanism actively counteracts potential induced degradation in PV modules, extending panel lifespan and stabilizing energy yield over a 20-30 year operating horizon - a feature rarely offered as standard in commercial inverters of this power class.

Robust IP66 enclosure

IP66 ingress protection (higher than the common IP65 in this segment) combined with forced-air cooling provides resistance to dust and powerful water jets, allowing outdoor installation in harsh industrial conditions without additional protective housing.

Remote monitoring and OTA updates

Remote diagnostics and OTA firmware updates reduce servicing costs for large commercial installations spread across multiple sites, shortening service response times without requiring on-site technician visits.

Trade-offs
Limited track record in the C&I segment

HYXiPower is a relatively young manufacturer without an established position in the 50-125 kW commercial segment comparable to tier-1 brands (Huawei, Sungrow, SMA). Independent sources report conflicting warranty lengths for the brand's products (ranging from 10 to 25 years depending on the source and purchase date), making it harder for investors to reliably assess lifecycle service costs.

AFCI offered as optional, not standard

Arc-fault circuit interruption (AFCI) is available only as an option rather than standard equipment, whereas some competing commercial inverters in this power class include AFCI as a baseline feature, potentially adding cost on projects requiring strict fire-safety compliance.

Potential vendor lock-in with DC-coupled design

DC-coupled integration with energy storage requires a dedicated battery cabinet compatible with the inverter (e.g., within the HYX-H-ET family), limiting flexibility to pair with third-party BESS compared to AC-coupled solutions, which are generally more universal for third-party storage integration.

Inverter Power Euro eff. MPPT Weight Difference
HYXiPower HYX-H110K-ET 110 kW 98.0% - 95.0 kg You are here
110M1-HYB 110 kW 98.4% - 108.0 kg +0.4 pp efficiency, 13.0 kg heavier
110M1-HYA 110 kW 98.4% - 78.0 kg +0.4 pp efficiency, 17.0 kg lighter
CH3-110K-T8 110 kW 97.5% 2 145.0 kg -0.5 pp efficiency, 50.0 kg heavier
gridsave 110 TL3-S GEN2 110 kW - - 80.0 kg 15.0 kg lighter
100M1-HYB 100 kW 98.4% - 108.0 kg -10.0 kW, +0.4 pp efficiency, 13.0 kg heavier
100M1-HYA 100 kW 98.4% - 78.0 kg -10.0 kW, +0.4 pp efficiency, 17.0 kg lighter
SUN-100K-SG02HP3-EU-GM8 100 kW 98.1% 10 161.7 kg -10.0 kW, 66.7 kg heavier
SUN-100K-SG02HP3-EU-GM10 100 kW 98.1% 10 161.7 kg -10.0 kW, 66.7 kg heavier

About the HYX-H-ET series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

What is DC coupling in the HYX-H-ET inverters and what are its benefits?
DC coupling means the energy storage system is connected on the DC side, upstream of the inverter, instead of through a separate AC converter. In the HYX-H-ET series this reduces the number of energy conversions, improving overall PV-ESS system efficiency and lowering investment cost, since a separate battery inverter is not required.
How many MPPT trackers does the HYX-H-ET series have and does it matter under uneven shading?
The HYX-H-ET inverters feature eight independent MPPT trackers with intelligent dynamic MPPT. Each string section is monitored and optimized separately, which is especially important in commercial installations with varying roof angles, orientations, or partial shading from chimneys or neighboring buildings, resulting in higher energy yield.
Are the HYX-H-ET inverters suitable for outdoor use in harsh conditions?
Yes, the enclosure has an IP66 protection rating, providing full resistance to dust and powerful water jets, while air cooling ensures stable operation even at high ambient temperatures typical of outdoor industrial installations. The compact housing simplifies outdoor mounting without the need for extra protective shelters.
What power range does the HYX-H-ET series cover and what installations is it suited for?
The series covers three-phase inverters ranging from 50 to 125 kW, making them suitable for commercial and industrial installations such as production halls, logistics centers, or PV farms paired with energy storage. This power range lets integrators match a single unit to specific demand without combining several smaller inverters.
What is PID regeneration in the HYX-H-ET inverters and is it worth having?
PID regeneration counteracts potential-induced degradation, a phenomenon where the voltage difference between cells and the panel frame gradually reduces module output. The inverter periodically reverses the voltage polarity to neutralize this effect. It is especially valuable in large commercial installations, where even a small power loss across many panels translates into measurable financial losses over the system's lifetime.
Do the HYX-H-ET inverters protect against fires caused by electrical arcing?
Yes, an optional AFCI arc-fault detection system with rapid shutdown is available. Combined with Type II surge protection on both the DC and AC sides, this increases installation safety, which matters greatly in large commercial systems where fire risk directly affects building insurance terms.