Skip to main content

Hypontech HES-4000

4 kW Hybrid Single-phase Battery-ready
Datasheet PDF
Rated AC (kW)
4.00
Typical for its class
Euro eff. (%)
97.6
Strong · top 16%
MPPT
2
Typical · median 2
Max DC (V)
600
Typical · median 600 V
Weight (kg)
18.4
Typical · median 18.5 kg
Warranty (yrs)
-
Not published

The Hypontech HES LV series comprises single-phase hybrid inverters in the 3-6 kW range, built for installations where flexibility in PV array sizing and resilience during grid outages matter most. What sets this series apart is a PV Ratio up to 2.0, allowing significantly more panel capacity to be connected than the inverter's rated output, which lowers the cost per installed watt and makes better use of limited roof space. The proprietary Shadow Scan algorithm reduces energy losses caused by partial string shading, a real advantage on irregular roof layouts and in dense urban settings. These inverters deliver full grid independence through a back-up mode rated at twice nominal power, making it easier to start demanding household loads during an outage. With support for both lithium and lead-acid batteries and automatic adaptation to the BMS, the series fits equally well in new storage systems and retrofits. Another advantage is string-level monitoring through the HYPON.CLOUD platform, which simplifies servicing and speeds up fault detection. An IP65 enclosure and a wide operating temperature range make the HES LV a solid choice for installers working across varied climates, suiting single-family homes as well as smaller commercial systems.

Ranking

1,295 inverters from 3 to 6 kW
Metric This inverter Median Position in class Rank in class
European efficiency 97.6% 97.1% Strong · top 16% 124
MPPT trackers 2 2 Typical 73
Max DC input voltage 600 V 600 V Typical 333
Weight per kW 4.6 4.0 Typical 754
Warranty - 5 yrs Not published -
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 4 kW Continuous output
Max apparent power 4.40 kVA
Phases Single-phase
Nominal AC voltage 230 V 220/230/240
Max AC current 19.1 A
Grid frequency 50 Hz Range 50/60
Power factor 0.8ind - 0.8cap
Harmonic distortion (THD) 3.0 %
Max DC input power 8.00 kW DC/AC ratio 2.00
Max DC voltage 600 V Caps the string length
MPPT voltage range 80 to 550 V
Start-up voltage 70 V
MPPT trackers 2 1 string each
Max input current per MPPT 16.0 A Must exceed the panel's Imp
Max short-circuit current per MPPT 20.0 A Must exceed the panel's Isc
European efficiency 97.6 % Weighted across part loads
Max efficiency 98.0 % Best single operating point
Battery port Yes
Battery voltage 40-60
Max charge current 120.0 A
Max discharge current 120.0 A
Backup power 6.00 kW Output during a grid outage
Dimensions 365 × 455 × 182 mm Height × width × depth
Weight 18.4 kg 4.6 kg per kW
Enclosure IP65
Cooling natural
Operating temperature -30 to 60 °C
Max humidity 100 %
Max altitude 3000 m
Interfaces Wi-FiEthernetDisplay
Protocols RS485Wi-Fi4GLANCAN
Protection Surge protection

Pros and cons

5 positive · 2 caution
What owners get
PV Ratio up to 2.0 for module flexibility

HES LV inverters allow connecting PV module power up to twice the inverter's rated AC power, exceeding the typical 1.3-1.5 range offered by many tier-1 competitors. This enables better use of limited roof area and lowers installation cost per watt of inverter capacity.

Shadow Scan algorithm reduces shading losses

The proprietary Shadow Scan algorithm optimizes string performance under partial shading conditions, which is particularly relevant for irregular roof layouts common in urban and residential installations. This feature is less commonly found in the 3-6 kW power segment.

Back-up mode with 2x overload capacity

With up to 200% rated power overload in island (off-grid) mode, HES LV makes it easier to start demanding household loads (e.g., pumps, compressors) during grid outages - a more favorable spec than the standard 110-130% offered by many competitors.

Broad battery chemistry compatibility

Automatic BMS adaptation for both lithium-ion and lead-acid batteries allows HES LV to be used in new energy storage installations as well as when expanding existing battery systems from other manufacturers, increasing flexibility for installers.

String-level monitoring via HYPON.CLOUD

String-level cloud monitoring through HYPON.CLOUD enables faster remote fault diagnosis and servicing, reducing response time compared to inverters offering only device-level monitoring.

Trade-offs
Limited brand track record

Hypontech was founded in 2018, and the HES LV series launched in 2023, meaning there is no long-term field performance history compared to established tier-1 brands (e.g., SolaX, Growatt, Huawei) with over a decade of market presence. This may matter when evaluating long-term reliability and service support.

Inconsistent publicly available warranty terms

Publicly available Hypontech warranty documents for different series (HPS/HPK/HPT vs. HHS/HHT) show varying terms (5 to 10 years) depending on document date and market, making it difficult to confirm current HES LV terms without contacting a local distributor.

Inverter Power Euro eff. MPPT Weight Difference
Hypontech HES-4000 4 kW 97.6% 2 18.4 kg You are here
SE4000H 4 kW 99.0% - 12.0 kg +1.4 pp efficiency, 6.4 kg lighter
Sigen Hybrid 4.0 SP2 4 kW 98.2% 2 11.5 kg +0.6 pp efficiency, 6.9 kg lighter
HYX-H4K-HSA2 4 kW 98.2% - 38.0 kg +0.6 pp efficiency, 19.6 kg heavier
SUN2000L-4KTL 4 kW 97.9% 2 10.6 kg +0.3 pp efficiency, 7.8 kg lighter
MOD 4000TL3-HU 4 kW 97.8% 2 19.0 kg Similar on paper
Sigen Hybrid 4.0 TP2 4 kW 97.8% 2 19.5 kg 1.1 kg heavier
X3-HYB-4.0-P 4 kW 97.7% 3 38.0 kg +1 MPPT, 19.6 kg heavier
X3-IES-4K-P 4 kW 97.7% 3 40.0 kg +1 MPPT, 21.6 kg heavier

About the HES LV series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

What does a PV Ratio of up to 2.0 mean on Hypontech HES LV inverters, and can I connect more panels than the inverter's rated power?
A PV Ratio of 2.0 means the HES LV inverter can accept solar panels with a total capacity up to twice its rated output. For example, a 5 kW unit can support up to 10 kW of PV modules. This oversizing allows better use of limited roof space and lowers installation cost per watt, without needing to upgrade to a higher-power inverter.
How does the Shadow Scan algorithm work, and is it worth having on a partially shaded roof?
Shadow Scan is Hypontech's proprietary algorithm that detects partial shading on individual strings and dynamically adjusts the MPPT operating point to reduce energy losses. This matters on irregular roof shapes, around chimneys or dormers, and in dense urban settings where shadows fall on only part of the array at different times of day. It's worth choosing this model if the roof isn't fully unobstructed.
Does the Hypontech HES LV inverter work without grid power (back-up mode)?
Yes, the HES LV series supports a back-up mode that provides full off-grid independence during a grid outage. In this mode the inverter delivers up to twice its rated power as overload capacity, making it easier to start demanding appliances such as pumps, refrigerators, or other household equipment with high starting currents. It's a practical feature for homes where power continuity matters.
Which batteries are compatible with HES LV inverters?
Hypontech HES LV inverters support both lithium and lead-acid batteries, automatically adapting to the connected battery's BMS via CAN/RS485 communication. This compatibility makes the series suitable for both new installations with battery storage and for expanding existing systems with additional batteries of a different type.
Can HYPON.CLOUD monitoring show data for each panel string separately?
Yes, HES LV inverters provide string-level monitoring through the HYPON.CLOUD platform. This means an installer or homeowner can track the performance of each panel string independently, which greatly simplifies servicing and allows quick detection of issues such as a faulty panel or a wiring problem, without needing an on-site visit.
Can Hypontech HES LV inverters be installed outdoors in challenging climate conditions?
Yes, the IP65-rated enclosure and wide operating temperature range allow HES LV inverters to be mounted outdoors without additional shielding. This is a significant advantage for installers who want to save space inside technical rooms or who work in regions with large temperature and humidity swings.