Skip to main content

Hopewind HSHV330K-G02

330 kW Grid-tie Three-phase
Datasheet PDF
Rated AC (kW)
330.00
Strong · top 11%
Euro eff. (%)
98.7
Typical · median 98.5%
MPPT
8
Typical · median 8
Max DC (V)
1500
Strong · top 23%
Weight (kg)
155.0
Typical · median 99.0 kg
Warranty (yrs)
-
Not published

The HSHV-G02 series consists of industrial-grade string inverters engineered for large-scale solar farms and utility installations. Built around 8 independent MPPT trackers, the design adapts flexibly to varied module layouts and uneven shading, delivering real gains in energy yield across challenging site conditions. The use of advanced SiC transistor topology translates into high conversion efficiency and extended lifespan of key components. The series stands out with its IP66 enclosure and C5 anti-corrosive rating, making it resistant to dust, moisture, and aggressive coastal or industrial environments where competing units tend to degrade faster. These inverters also handle grids with low short-circuit ratios, making them suitable for regions with weaker power infrastructure. Safety is reinforced by an optional AFCI arc-fault detection system and an explosion-proof valve that protects on-site service personnel. Investors will also value built-in support for PID recovery and SVG functionality, along with PLC communication that reduces wiring costs. Integration with the hopeCloud platform gives operators continuous monitoring, fault waveform recording, and smart IV curve diagnostics, shortening service response times and lowering maintenance costs for large installations.

Ranking

238 inverters from 100 to 500 kW
Metric This inverter Median Position in class Rank in class
European efficiency 98.7% 98.5% Typical 43
MPPT trackers 8 8 Typical 82
Max DC input voltage 1500 V 1100 V Strong · top 23% 1
Weight per kW 0.5 0.7 Typical 66
Warranty - 5 yrs Not published -
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 330 kW Continuous output
Phases Three-phase
Nominal AC voltage 800 V 640~920 V
Max AC current 238.2 A
Grid frequency 50 Hz Range 45~55 Hz / 55~65 Hz
Power factor 0.8 leading~0.8 lagging
Harmonic distortion (THD) 3.0 %
Max DC voltage 1500 V Caps the string length
MPPT voltage range 500 to 1500 V
Start-up voltage 550 V
MPPT trackers 8 4 strings each
Max input current per MPPT 65.0 A Must exceed the panel's Imp
Max short-circuit current per MPPT 97.5 A Must exceed the panel's Isc
European efficiency 98.7 % Weighted across part loads
Max efficiency 99.0 % Best single operating point
Dimensions 967 × 1208 × 396 mm Height × width × depth
Weight 155.0 kg 0.5 kg per kW
Enclosure IP66
Cooling forced-air
Operating temperature -30 to 60 °C
Max altitude 4000 m
Interfaces Wi-FiDisplay
Protocols RS485PLCWi-FiWiLAN
Protection AFCIDC switchSurge protection

Pros and cons

5 positive · 3 caution
What owners get
BNEF Tier 1 manufacturer status

Hopewind was added to BloombergNEF's Tier 1 Photovoltaic Inverter Manufacturer list in the Q2 2024 Global PV Market Outlook, confirming bankability and financial standing required for large-scale PV plant financing.

8 MPPT trackers and high conversion efficiency

The 8 independent MPPTs (65 A per input, 500-1500 V range) allow flexible string configuration under uneven shading, and the maximum efficiency of 99.01% with 98.70% European efficiency rank in the upper tier of the 320-385 kW string inverter segment.

IP66 enclosure and C5 anti-corrosion class

IP66 protection combined with C5 anti-corrosion rating and a -30°C to +60°C operating range enables deployment in coastal and industrial environments, where typical IP65 inverters corrode faster and require more frequent servicing.

AFCI and explosion-relief valve

The optional AFCI arc-fault detection system and explosion-relief valve enhance service personnel safety in large utility-scale installations, where string fault fire risk is a significant operational concern.

hopeCloud monitoring and I-V curve diagnostics

Integration with the hopeCloud platform enables remote error logging and intelligent I-V curve diagnostics, which in practice shortens service response time and lowers OPEX for large PV plants compared to solutions without remote diagnostics.

Trade-offs
SiC vs. IGBT topology ambiguity

Marketing materials emphasize a SiC transistor topology, yet newer preliminary documentation (2026 datasheet) for higher-power variants in the G02 family labels the DC/AC stage as IGBT, creating ambiguity about the actual switching technology used across all power ratings and warranting verification with the manufacturer before purchase.

Limited price and warranty transparency

The absence of a publicly standardized per-kW price list and clearly stated warranty terms (quotes are negotiated per project) makes direct TCO comparison against established tier-1 vendors such as Sungrow or Huawei more difficult.

Shorter Tier 1 track record

Hopewind only achieved BNEF Tier 1 status in 2024, meaning a shorter history of utility-scale references compared to manufacturers with 10+ years on that list, which may matter when assessing long-term service support risk.

Alternatives

All Hopewind inverters
Inverter Power Euro eff. MPPT Weight Difference
Hopewind HSHV330K-G02 330 kW 98.7% 8 155.0 kg You are here
SolarEdge TerraMax Inverter SE330K 330 kW 98.8% - 175.0 kg 20.0 kg heavier
SOFAR 330KTLX0 330 kW 98.8% - 113.0 kg 42.0 kg lighter
HSHV330K-G01 330 kW 98.7% 8 142.0 kg 13.0 kg lighter
330TL M12 330 kW 98.6% 12 150.0 kg +4 MPPT, 5.0 kg lighter
SG333HX 333 kW 98.8% 12 116.0 kg +3.0 kW, +4 MPPT, 39.0 kg lighter
X3-GRD-333K-HV 333 kW 98.8% 6 130.0 kg +3.0 kW, -2 MPPT, 25.0 kg lighter
370H2 333 kW 98.8% 14 150.0 kg +3.0 kW, +6 MPPT, 5.0 kg lighter
MAX 333K-X 333 kW 98.5% 6 126.0 kg +3.0 kW, -2 MPPT, 29.0 kg lighter

About the HSHV-G02 series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

What is the maximum power output and how many MPPT trackers does the Hopewind HSHV-G02 series have?
The HSHV-G02 series ranges from 320 to 385 kW rated power depending on the model (e.g., HSHV320K-G02, HSHV385K-G02). Each unit features 8 independent MPPT trackers with a voltage range of 500-1500 V, allowing flexible string configuration and minimizing losses from partial shading or mixed module orientations in large-scale PV plants.
Do HSHV-G02 inverters operate in extreme temperatures and harsh environmental conditions?
Yes, the units operate within a -30°C to +60°C range and can start up even at -40°C. The IP66 enclosure with C5 anti-corrosion rating protects against dust, moisture, and aggressive coastal or industrial environments, making the series well-suited for desert climates, coastal regions, and utility-scale installations exposed to demanding conditions.
What is the AFCI function in HSHV-G02 inverters and is it worth having?
AFCI is an optional arc-fault detection system for the DC circuit that automatically shuts down the inverter when it detects a dangerous arcing condition that could lead to fire. In large PV plants with extensive wiring that's hard to inspect continuously, this feature significantly improves service personnel safety and reduces material loss risk, making it a sensible choice for utility-scale projects.
How does the HSHV-G02 differ from standard competitor string inverters?
The key differentiator is the use of SiC transistors, which push conversion efficiency above 99 percent and extend component lifespan compared to conventional silicon-based topologies. The series also supports PID recovery, SVG grid-stabilization functionality, and operation on weak grids with low short-circuit ratios, making it more versatile for regions with underdeveloped power infrastructure than many competing models.
What does monitoring and diagnostics look like for installations using HSHV-G02 inverters?
The inverters integrate with the hopeCloud platform, enabling continuous performance monitoring, fault history logging, and intelligent I-V curve diagnostics without requiring on-site physical inspection. PLC communication also reduces control wiring costs. This setup significantly shortens service response times and lowers operating costs for large solar farms.
What types of PV installations is the Hopewind HSHV-G02 series best suited for?
The HSHV-G02 series is designed for large-scale PV plants and utility installations, not residential microsystems. High unit power (320-385 kW), 8 MPPT trackers, and a rugged IP66/C5 enclosure make it best suited for commercial and industrial projects, including coastal sites, desert environments, and areas with weak grid infrastructure.