Skip to main content

Hopewind hopeSunHV 250KTL

250 kW Grid-tie Three-phase
Datasheet PDF
Rated AC (kW)
250.00
Strong · top 24%
Euro eff. (%)
98.5
Typical · median 98.5%
MPPT
12
Strong · top 12%
Max DC (V)
1500
Strong · top 23%
Weight (kg)
115.0
Typical · median 99.0 kg
Warranty (yrs)
-
Not published

The Hopewind hopeSunHV series is a solution built for utility-scale solar farms, engineered around a 1500V string-inverter architecture that replaces traditional central inverters in large PV plants. These units stand out thanks to their high number of MPPT channels, enabling precise maximum power point tracking even under uneven shading or soiling across individual strings, which minimizes energy losses compared to classic central inverters. The design is fully compatible with bifacial modules of high unit power, letting investors freely choose the latest high-output panels without worrying about inverter-side technical constraints. A key advantage is the built-in PLC communication, which removes the need for additional signal cabling between strings and the central unit, meaningfully shortening installation time and lowering the project's overall BoS costs. The hopeSunHV series is aimed at PV farm developers and investors, general contractors, and solar plant operators seeking a balance between string-level configuration flexibility and the economies of scale typical of central inverters. The result is higher system availability, easier modular servicing, and a better capacity utilization ratio, which translates into a lower LCOE for the entire installation.

Ranking

238 inverters from 100 to 500 kW
Metric This inverter Median Position in class Rank in class
European efficiency 98.5% 98.5% Typical 95
MPPT trackers 12 8 Strong · top 12% 7
Max DC input voltage 1500 V 1100 V Strong · top 23% 1
Weight per kW 0.5 0.7 Typical 65
Warranty - 5 yrs Not published -
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 250 kW Continuous output
Max AC power 255.00 kW Short-term output above the rating
Phases Three-phase
Nominal AC voltage 800 V 680~880V
Max AC current 184.0 A
Grid frequency 50 Hz
Power factor 0.8 leading~0.8 lagging
Harmonic distortion (THD) 3.0 %
Max DC input power 375.00 kW DC/AC ratio 1.50
Max DC voltage 1500 V Caps the string length
MPPT voltage range 500 to 1500 V
Start-up voltage 500 V
MPPT trackers 12 2 strings each
Max input current per MPPT 30.0 A Must exceed the panel's Imp
Max short-circuit current per MPPT 45.0 A Must exceed the panel's Isc
European efficiency 98.5 % Weighted across part loads
Max efficiency 99.0 % Best single operating point
Dimensions 809 × 1090 × 339 mm Height × width × depth
Weight 115.0 kg 0.5 kg per kW
Enclosure IP66
Cooling forced-air
Operating temperature -25 to 60 °C
Max altitude 4000 m
Interfaces Display
Protocols RS485PLC
Protection DC switchSurge protection

Pros and cons

5 positive · 2 caution
What owners get
12 MPPT channels per unit

The hopeSunHV 250KTL model features 12 independent MPPT channels (24 DC inputs), enabling very precise maximum power point tracking under uneven string shading - significantly more than the typical 6-8 channels found in competing string inverters of this power class.

High conversion efficiency

A maximum efficiency of 99.01% and European efficiency of 98.52% (manufacturer data) place the series in the upper tier of the 1500V utility-scale inverter segment, translating into a real increase in annual energy yield for large-scale installations.

BNEF Tier 1 status since Q2 2024

Hopewind was added to BloombergNEF's Tier 1 Photovoltaic Inverter Manufacturer list in May 2024, a bankability indicator recognized by banks and EPCs - projects using these inverters find it easier to secure non-recourse financing.

Built-in PLC eliminates signal cabling

Integrated PLC communication removes the need for a separate signal network between strings and the collection unit, which in practice shortens installation time and lowers BoS costs compared to solutions requiring conventional RS485 wiring.

High IP66 ingress protection rating

The IP66-rated enclosure, weighing up to 115 kg at dimensions of 1090×809×339 mm, allows outdoor mounting without additional shelter structures - a standard requirement for utility-scale farms that reduces ancillary infrastructure costs.

Trade-offs
Shorter track record than Tier 1 leaders

Hopewind only gained BNEF Tier 1 status in 2024, while Huawei and Sungrow have held this status for several years with a multi-gigawatt track record - investors may have limited access to long-term reliability data under utility-scale conditions.

Limited service network in Europe

Compared to manufacturers with an established European presence (Huawei, SMA, Sungrow), local service and spare parts availability for hopeSunHV outside China may be narrower, lengthening response times for failures in utility-scale projects.

Alternatives

All Hopewind inverters
Inverter Power Euro eff. MPPT Weight Difference
Hopewind hopeSunHV 250KTL 250 kW 98.5% 12 115.0 kg You are here
SOFAR 250KTLX0 250 kW 98.8% - 111.0 kg +0.3 pp efficiency, 4.0 kg lighter
SG250HX-20 250 kW 98.8% 6 106.0 kg +0.3 pp efficiency, -6 MPPT, 9.0 kg lighter
SPI250K-B-H 250 kW 98.8% 12 99.0 kg +0.3 pp efficiency, 16.0 kg lighter
MAX 250KTL3-X HV 250 kW 98.7% - 99.0 kg 16.0 kg lighter
XGI 1500-250/250-600 250 kW - 1 131.5 kg -11 MPPT, 16.5 kg heavier
MAX 253KTL3-X HV 253 kW 98.5% - 109.0 kg +3.0 kW, 6.0 kg lighter
Solis-255K-EHV-5G-PLUS 255 kW 98.8% 12 113.0 kg +5.0 kW, +0.3 pp efficiency, 2.0 kg lighter
SOFAR 255KTL-HV 255 kW 98.7% 12 99.0 kg +5.0 kW, 16.0 kg lighter

About the hopeSunHV series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

How many MPPT channels does the Hopewind hopeSunHV series have and why does it matter?
hopeSunHV models, such as the hopeSunHV 250KTL, feature 12 independent MPPT trackers (12 × 2 DC inputs). This high channel count allows strings to be split into smaller groups tracked separately, reducing energy losses from uneven shading, soiling, or panel orientation - a common issue on large PV farms where a central inverter with a single tracker would lose significantly more energy.
Is the hopeSunHV compatible with high-power bifacial modules?
Yes, the hopeSunHV's string architecture, rated at 1500V DC with an MPPT operating window of 500-1500V, is fully compatible with high-power bifacial modules. Investors can select the latest panels with high currents and power ratings without worrying about technical limitations, since the design requires no derating or additional string calculations.
How does PLC communication work in the hopeSunHV and what does it mean for installation costs?
hopeSunHV inverters use built-in PLC (power line communication), which sends control data over the existing DC wiring instead of requiring separate signal cabling between strings and the central unit. In practice, this shortens on-site installation time and meaningfully lowers BoS (Balance of System) costs on utility-scale projects.
What IP rating does the hopeSunHV series have, and is it suitable for outdoor operation?
hopeSunHV inverters carry an IP66 protection rating, meaning full resistance to dust and powerful water jets. This allows the units to operate without an additional shelter or container enclosure in harsh weather conditions, which is standard practice for large-scale PV farms installed in open terrain.
How does the hopeSunHV differ from a traditional central inverter in a PV plant?
Unlike central inverters, the hopeSunHV uses a string architecture with multiple independent MPPTs, offering greater configuration flexibility and higher system availability - a single module failure doesn't take down the entire plant. It still retains the economy of scale typical of central inverters thanks to high unit power (e.g., 250 kW per unit) and simplified PLC-based wiring.
What is the maximum efficiency of the hopeSunHV inverter?
hopeSunHV inverters, such as the 250KTL model, reach a maximum efficiency of 99.01% and a European efficiency of 98.52%. These high values translate into lower DC/AC conversion losses across an entire PV plant, directly contributing to a lower LCOE for the installation.