Skip to main content

Hopewind hopeSun 110KTL

110 kW Grid-tie Three-phase
Datasheet PDF
Rated AC (kW)
110.00
Weak · bottom 9%
Euro eff. (%)
98.3
Typical · median 98.5%
MPPT
4
Weak · bottom 22%
Max DC (V)
1100
Typical · median 1100 V
Weight (kg)
89.0
Weak · bottom 18%
Warranty (yrs)
-
Not published

The hopeSun KTL series comprises transformerless grid-tied inverters built for commercial and industrial installations, where power density and resilience to harsh operating conditions both matter. The units feature four independent MPPT trackers, giving designers the flexibility to match string configurations to irregular rooftops or partially shaded sections of a plant without sacrificing overall system performance. The DC inputs handle up to 20A per channel, making them fully compatible with modern, high-power 210mm PV modules widely used in C&I projects. The series stands out from competing products through features that simplify operation: touch-free commissioning via a mobile app and a built-in interface for the zero export function, allowing compliance with local grid requirements without extra hardware. Uptime is supported by redundant AC and DC power supply and smart air cooling, while an IP65-rated enclosure and an operating range from -40 to +60°C allow mounting both on industrial rooftops and in open-field environments. An optional PID recovery function plus built-in Type II surge protection devices extend system lifespan, making this series a dependable choice for integrators who prioritize reliability and straightforward maintenance.

Ranking

238 inverters from 100 to 500 kW
Metric This inverter Median Position in class Rank in class
European efficiency 98.3% 98.5% Typical 113
MPPT trackers 4 8 Weak · bottom 22% 137
Max DC input voltage 1100 V 1100 V Typical 113
Weight per kW 0.8 0.7 Weak · bottom 18% 193
Warranty - 5 yrs Not published -
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 110 kW Continuous output
Max AC power 121.00 kW Short-term output above the rating
Phases Three-phase
Nominal AC voltage 400 V 300~520 V
Max AC current 174.6 A
Grid frequency 50 Hz
Power factor 0.8 leading~0.8 lagging
Harmonic distortion (THD) 3.0 %
Max DC input power 165.00 kW DC/AC ratio 1.50
Max DC voltage 1100 V Caps the string length
MPPT voltage range 200 to 1000 V
Start-up voltage 200 V
MPPT trackers 4
Max input current per MPPT 65.0 A Must exceed the panel's Imp
Max short-circuit current per MPPT 100.0 A Must exceed the panel's Isc
European efficiency 98.3 % Weighted across part loads
Max efficiency 98.6 % Best single operating point
Dimensions 670 × 800 × 330 mm Height × width × depth
Weight 89.0 kg 0.8 kg per kW
Enclosure IP65
Cooling forced-air
Operating temperature -40 to 60 °C
Max altitude 4000 m
Interfaces Wi-FiDisplay
Protocols RS485Wi-Fi
Protection DC switchSurge protection

Pros and cons

5 positive · 2 caution
What owners get
Four independent MPPT trackers

The 4-MPPT configuration (versus the typical 2 MPPTs found in comparable C&I string inverters of this power class) allows flexible string layout on irregular roof sections or partially shaded arrays without reducing overall system yield.

BloombergNEF Tier 1 status

Hopewind was added to BloombergNEF's Global Tier 1 PV inverter manufacturer list in Q2 2024, one of only seven manufacturers worldwide on that list - a meaningful bankability signal for investors in commercial-scale installations.

High environmental resilience, IP65

IP65 ingress protection combined with an operating range of -40°C to +60°C allows mounting without an additional protective enclosure on both industrial rooftops and open-field sites, lowering balance-of-system (BoS) costs versus lower-IP-rated units.

Built-in zero-export function, no extra hardware

An integrated zero feed-in export interface meets local grid operator requirements without external sensors or controllers, cutting commissioning time and cost compared with solutions that require a separate export-limiter module.

AC/DC redundancy and remote commissioning

Redundant AC and DC power supply plus touchless mobile-app startup minimize the number of required site visits, which matters for large, geographically dispersed C&I portfolios.

Trade-offs
Limited public reliability track record

Unlike established Tier 1 manufacturers (Huawei, Sungrow, SMA) with years of publicly available field-failure data, Hopewind only reached BNEF Tier 1 status in 2024, meaning integrators have fewer independent, long-term reference datasets to assess field reliability on European markets.

20A maximum current per MPPT string

The 20A per-input DC limit, while compatible with current-generation 210mm modules, is lower than the 45-65A rating found on larger units within the same hopeSun family (60-110kW class), which may constrain long, high-current string layouts as module current ratings continue to rise.

Alternatives

All Hopewind inverters
Inverter Power Euro eff. MPPT Weight Difference
Hopewind hopeSun 110KTL 110 kW 98.3% 4 89.0 kg You are here
110 TL3-US 110 kW 98.8% 1 78.2 kg +0.5 pp efficiency, -3 MPPT, 10.8 kg lighter
S5-GC110K 110 kW 98.6% 10 91.0 kg +6 MPPT, 2.0 kg heavier
Solis-110K-HV-5G 110 kW 98.5% 9 82.0 kg +5 MPPT, 7.0 kg lighter
C6-110K-T12-40 110 kW 98.5% - 98.0 kg 9.0 kg heavier
PVM-110-TL 110 kW 98.5% 12 90.0 kg +8 MPPT, 1.0 kg heavier
XG110KTR-F 110 kW 98.5% 12 98.0 kg +8 MPPT, 9.0 kg heavier
MAX 110KTL3-X LV 110 kW 98.4% 10 84.0 kg +6 MPPT, 5.0 kg lighter
Sunny Tripower CORE2 STP 110-60 110 kW 98.4% 12 93.5 kg +8 MPPT, 4.5 kg heavier

About the hopeSun KTL series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

How does the Hopewind hopeSun KTL series differ from typical C&I string inverters on the market?
The key difference is four independent MPPT trackers, which let the inverter handle irregular roof layouts or partially shaded sections of a solar farm without reducing the overall system yield. It's also transformerless, boosting efficiency, and its redundant AC and DC power design provides greater operational continuity than simpler string inverters built for residential use.
Is the hopeSun KTL compatible with large 210mm solar modules?
Yes, the hopeSun KTL's DC inputs support up to 20A per MPPT string, making them fully compatible with modern, high-power 210mm modules widely used in commercial and industrial projects. This allows designers to build strings with fewer panels without exceeding the inverter's input parameters.
How does the zero-export function on hopeSun KTL inverters work, and does it require extra hardware?
The zero-export function is built directly into the inverter and limits grid feed-in to zero, which many local grid operators require for industrial installations. Unlike competing solutions, no external controller or meter needs to be purchased separately - the control interface is already integrated into the inverter.
Can hopeSun KTL inverters be installed outdoors in harsh weather conditions?
Yes, the enclosure has an IP65 rating, protecting the electronics from dust and water jets, and an operating range of -40°C to +60°C allows installation on industrial roofs as well as in open fields, including climates with large temperature swings. Smart air cooling further protects the electronics from overheating during hot months.
What does commissioning and setup look like for a hopeSun KTL inverter during installation?
The series features touch-free commissioning via a mobile app, eliminating the need to physically connect a laptop or use onboard buttons during setup. Installers can configure parameters and start the inverter remotely from a smartphone, which shortens installation time and reduces the number of service visits needed at commissioning stage.
Does the PID recovery function in hopeSun KTL actually extend the lifespan of a solar installation?
Yes, the optional PID recovery function helps reverse potential-induced degradation, an effect that weakens modules operating under high voltage in humid conditions. Combined with the built-in Class II surge protectors, it significantly reduces the risk of premature power loss in panels, improving long-term return on investment for the system.