Rated AC (kW)
120.00
Weak · bottom 20%
Euro eff. (%)
98.3
Typical · median 98.5%
MPPT
12
Strong · top 11%
Max DC (V)
1100
Typical · median 1100 V
Weight (kg)
98.5
Weak · bottom 20%
Warranty (yrs)
-
Not published
Ranking
Metric
This inverter
Median
Position in class
Rank in class
European efficiency
98.3%
98.5%
Typical
128
MPPT trackers
12
8
Strong · top 11%
7
Max DC input voltage
1100 V
1100 V
Typical
121
Weight per kW
0.8
0.7
Weak · bottom 20%
226
Warranty
-
5 yrs
Not published
-
Colour key
Strong - top 25%
Typical - middle 50%
Weak - bottom 25%
Specifications
Rated AC power
120 kW
Continuous output
Max AC power
132.00 kW
Short-term output above the rating
Max apparent power
132.00 kVA
Phases
Three-phase
Nominal AC voltage
400 V
320~440
Max AC current
191.3 A
Grid frequency
50 Hz
Range 45~55 / 55~65
Power factor
0.8 leading - 0.8 lagging
Harmonic distortion (THD)
3.0 %
Max DC voltage
1100 V
Caps the string length
MPPT voltage range
180 to 1000 V
Start-up voltage
200 V
MPPT trackers
12
2 strings each
Max input current per MPPT
30.0 A
Must exceed the panel's Imp
Max short-circuit current per MPPT
45.0 A
Must exceed the panel's Isc
European efficiency
98.3 %
Weighted across part loads
Max efficiency
98.6 %
Best single operating point
Dimensions
678 × 1008 × 343 mm
Height × width × depth
Weight
98.5 kg
0.8 kg per kW
Enclosure
IP66
Cooling
forced-air
Operating temperature
-30 to 60 °C
Max humidity
100 %
Max altitude
5000 m
Interfaces
Wi-FiBluetoothDisplay
Protocols
RS485WiFi4GModbus-RTUBluetoothPower line communication
Protection
AFCIDC switchSurge protection
Alternatives
Inverter
Power
Euro eff.
MPPT
Weight
Difference
GoodWe
GW120K-HT
120 kW
98.3%
12
98.5 kg
You are here