Skip to main content

Ginlong Solis S6-EH2P11.4K03-SV-YD-L-US

11.4 kW Hybrid Single-phase Battery-ready
Datasheet PDF
Rated AC (kW)
11.40
Strong · top 20%
Euro eff. (%)
-
Not published
MPPT
3
Strong · top 13%
Max DC (V)
550
Weak · bottom 24%
Weight (kg)
65.8
Weak · 37.8 kg above median
Warranty (yrs)
-
Not published

The S6-EH2P series comprises Solis hybrid energy storage inverters built for split-phase, low-voltage grids where uninterrupted home power supply is the priority. The series stands out with seamless switching between grid-tied and off-grid operation in under 10 ms, so homeowners barely notice a grid outage. These inverters support 300% overload capacity in off-grid mode, allowing battery-powered motors, pumps, or air conditioners to start without issue. Installation flexibility comes from support for both DC and AC coupling, making it easier to expand an existing PV array or integrate additional energy sources through the dedicated Smart Port, including generators or wind turbines. Smart load prioritization extends backup runtime for critical appliances, while the ability to connect up to six units in parallel lets the whole system scale as energy demands grow. Integrated arc-fault protection and a rapid shutdown transmitter further reinforce installation safety. This makes the series a strong fit for installers and investors seeking a dependable storage solution for single-family homes exposed to frequent grid disruptions.

Ranking

1,093 inverters from 6 to 12 kW
Metric This inverter Median Position in class Rank in class
European efficiency - 97.5% Not published -
MPPT trackers 3 2 Strong · top 13% 26
Max DC input voltage 550 V 800 V Weak · bottom 24% 747
Weight per kW 5.8 3.0 Weak · bottom 7% 999
Warranty - 5 yrs Not published -
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 11.4 kW Continuous output
Max apparent power 11.40 kVA
Phases Single-phase
Nominal AC voltage 240 V 193.6-242 V / 211-264 V
Max AC current 51.8 A
Grid frequency 60 Hz Range 59.5-60.5 Hz / 58.8-61.2 Hz
Power factor 0.8 leading - 0.8 lagging
Harmonic distortion (THD) 3.0 %
Max DC input power 18.24 kW DC/AC ratio 1.60
Max DC voltage 550 V Caps the string length
MPPT voltage range 100 to 450 V
Start-up voltage 100 V
MPPT trackers 3 2 strings each
Max input current per MPPT 40.0 A Must exceed the panel's Imp
Max short-circuit current per MPPT 50.0 A Must exceed the panel's Isc
Max efficiency 96.0 % Best single operating point
CEC efficiency 95.5 % California Energy Commission weighting
Battery port Yes
Battery voltage 40-60 V
Max charge current 237.5 A
Max discharge current 237.5 A
Backup power 11.40 kW Output during a grid outage
Grid-forming Yes
Dimensions 930 × 534 × 297 mm Height × width × depth
Weight 65.8 kg 5.8 kg per kW
Enclosure IP66
Cooling forced-air
Noise 65 dB
Operating temperature -25 to 60 °C
Max humidity 100 %
Max altitude 4000 m
Interfaces Wi-FiEthernetBluetoothDisplay
Protocols RS485CANBluetoothWi-FiLANCellular
Protection AFCI
Certifications IEEE 1547-2018IEEE1547.1-2020CA Rule 21SRD 2.0UL 1741 PVRSSUL 1699BUL 1998UL 1741UL 1741 SBCSA C22.2107.1-1FCC Part 15 Class B

Pros and cons

5 positive · 2 caution
What owners get
Grid/off-grid switchover <10 ms

A grid-to-island transfer time of under 10 ms makes power loss virtually imperceptible to homeowners, a meaningful edge over many competing hybrids that take 20-50 ms to switch over.

High surge overload capability

Per the datasheet, the series supports up to 300% of rated power for 1 s and 200% for 10 s in off-grid mode, enough to start motors, pumps, and AC compressors running on battery power without oversizing the unit.

Flexible DC and AC charging with Smart Port

Batteries can be charged from PV (DC) or from grid/generator (AC), and a dedicated Smart Port enables connection of generators or wind turbines - simplifying phased system expansion and integration of alternative energy sources.

Scalability via parallel operation

Support for paralleling up to six units allows the total storage system capacity to scale without replacing already-installed inverters, a relevant advantage as a household's energy needs grow.

Tier-1, bankable manufacturer since 2005

Ginlong Solis is a BNEF Tier-1 manufacturer operating since 2005, which supports project financing availability and lowers risk for investors and installers compared to less established brands.

Trade-offs
300% overload applies only to a 1-second surge

The 300% rated-power figure in off-grid mode refers strictly to a 1-second surge (with 200% for 10 s per the official datasheet), not continuous operation - this must be accounted for when sizing for loads with long startup times (e.g., large compressors) to avoid underestimating required capacity.

Built for split-phase grids, limited market portability

The S6-EH2P series is optimized for the North American split-phase 120/240V standard and is not a direct fit for three-phase 400V grids (most of Europe), where Solis offers a separate line (S6-EH3P) - limiting this particular series to split-phase markets.

Inverter Power Euro eff. MPPT Weight Difference
Ginlong Solis S6-EH2P11.4K03-SV-YD-L-US 11.4 kW - 3 65.8 kg You are here
MIN 11400TL-XH-US 11.4 kW - 4 20.5 kg +1 MPPT, 45.3 kg lighter
H2-11.4K-LS4-US 11.4 kW - - 48.0 kg 17.8 kg lighter
AC1-11.4-US / HI-11.4-US 11.4 kW - 3 38.0 kg 27.8 kg lighter
TSI-11.4K-US 11.4 kW - - 20.5 kg 45.3 kg lighter
X11402 / XVT114G03 11.4 kW - - 28.4 kg 37.4 kg lighter
SE 11K4HB-T2/LV-ULP 11.4 kW - 3 47.0 kg 18.8 kg lighter
LXP-LB-EU 12K 11.5 kW 96.0% 3 50.0 kg 15.8 kg lighter
SigenStor EC SP US-11.5 11.5 kW - 4 35.0 kg +1 MPPT, 30.8 kg lighter

About the S6-EH2P series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

How fast does the Solis S6-EH2P switch from grid to off-grid power during an outage?
The transfer time between grid-tied and off-grid operation is under 10 milliseconds, which is essentially unnoticeable to homeowners. Devices like computers, routers, or refrigerators won't reset, and lights won't even flicker. This makes the S6-EH2P function like a whole-home UPS rather than a standard battery backup that reconnects with a delay after an outage.
Can the Solis S6-EH2P start a well pump or air conditioner running on battery power alone?
Yes, the inverter supports overload up to 300% of rated power in off-grid mode, which in practice provides the surge current needed to start induction motors in pumps, air conditioners, or compressors. This is a key advantage over simpler storage systems that trip their overload protection and shut down when faced with high motor starting currents.
How is the S6-EH2P different from standard hybrid inverters sold in Europe?
The S6-EH2P series is built for split-phase (120/240 V) grids, common in North America, rather than the three-phase 230/400 V grid topology used across most of Europe. Beyond grid type, it stands out with its sub-10 ms off-grid transfer time, high overload capacity, and a Smart Port for connecting a generator or wind turbine, making it a premium solution for markets prone to frequent power outages.
Can a backup generator be connected to the S6-EH2P as an extra safeguard?
Yes, the inverter includes a dedicated Smart Port that allows a generator or wind turbine to be connected as a supplementary power source. The system automatically manages charging priority between available sources, which is especially valuable during extended outages when PV and battery power alone aren't enough to cover household demand.
How many S6-EH2P units can be connected in parallel to increase system capacity?
Up to six S6-EH2P inverters can be connected in parallel, scaling both rated power and overall storage capacity within a single system. This is particularly useful for phased installations, where a homeowner's energy needs grow over time - an installer can add another inverter rather than replacing the entire system.
What safety features does the S6-EH2P include, and is it safe for residential installation?
The inverter includes integrated arc-fault circuit interruption (AFCI), which detects dangerous DC arcing in the PV wiring, plus a rapid shutdown transmitter required by many fire safety codes. As a product from Ginlong Solis, a tier-1 Chinese manufacturer, the S6-EH2P meets certification requirements for its target markets, including UL 1741 and IEEE 1547.