Skip to main content

Ginlong Solis 40K

40 kW Hybrid Three-phase Battery-ready
Datasheet PDF
Rated AC (kW)
40.00
Weak · bottom 21%
Euro eff. (%)
97.3
Weak · bottom 9%
MPPT
-
Not published
Max DC (V)
1000
Typical · median 1100 V
Weight (kg)
76.0
Weak · 1.0 kg above median
Warranty (yrs)
-
Not published

The Solis Solarator S6-EH3P(30-60)K-H(21A) series is a three-phase, high-voltage hybrid inverter line built for commercial and industrial installations where maximizing solar utilization and withstanding grid instability both matter. Its standout advantage is DC and AC coupling support, allowing existing PV systems to be expanded flexibly without a full retrofit. The unit features two independent battery ports, so energy storage capacity can be scaled in stages as a site's needs grow, while compatibility with a wide range of lithium-ion battery modules helps keep overall system costs down. The inverter delivers sub-10ms grid and off-grid switching, virtually eliminating downtime for critical loads during grid outages. A three-in-one interface integrates PV, wind power, and diesel generators, making this model a versatile choice for areas with weak or unreliable grids. Built-in AI integration and VPP readiness enable dynamic tariff optimization and extra revenue from system flexibility. With support for parallel operation up to 600 kW, the series fits both smaller commercial projects and large-scale energy storage farms, standing out for a configuration flexibility that's hard to match among competitors.

Ranking

552 inverters from 30 to 100 kW
Metric This inverter Median Position in class Rank in class
European efficiency 97.3% 98.2% Weak · bottom 9% 371
MPPT trackers - 4 Not published -
Max DC input voltage 1000 V 1100 V Typical 298
Weight per kW 1.9 1.2 Weak · bottom 13% 449
Warranty - 5 yrs Not published -
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 40 kW Continuous output
Max apparent power 40.00 kVA
Phases Three-phase
Nominal AC voltage 400 V 304-460V
Max AC current 60.8 A
Grid frequency 50 Hz
Power factor 0.8 leading - 0.8 lagging
Harmonic distortion (THD) 3.0 %
Max DC input power 80.00 kW DC/AC ratio 2.00
Max DC voltage 1000 V Caps the string length
MPPT voltage range 150 to 850 V
Start-up voltage 180 V
Max input current per MPPT 42.0 A Must exceed the panel's Imp
Max short-circuit current per MPPT 60.0 A Must exceed the panel's Isc
European efficiency 97.3 % Weighted across part loads
Max efficiency 97.7 % Best single operating point
Battery port Yes
Battery voltage 150-800V
Max charge current 84.0 A
Max discharge current 84.0 A
Dimensions 880 × 530 × 290 mm Height × width × depth
Weight 76.0 kg 1.9 kg per kW
Enclosure IP66
Cooling forced-air
Operating temperature -25 to 60 °C
Max humidity 100 %
Max altitude 4000 m
Interfaces Wi-FiEthernetBluetoothDisplay
Protocols WIFILANBluetoothCAN-BMSCAN-ParallelRS485-MeterRS485DRMDIDO4G
Protection AFCIDC switchSurge protection
Certifications IEC/EN 62109-1/-2IEC/EN 61000-6-2/-4EN 55011G99VDE-AR-N 4105/VDE V 0124EN 50549-1/EN 50549-10PTPiREEVDE 0126/XP C15/VFR:2019NTS 631/RD 1699/UNE 217002CEI 0-21CEI 0-16C10/11NRS 097-2-1TOREIFS 2018.2IEC 62116IEC 61727DEWAMEAPEAPORTARIA Nº 140/PORTARIA Nº 515

Pros and cons

5 positive · 2 caution
What owners get
Sub-10ms grid-to-off-grid transfer

A single unit switches from on-grid to off-grid mode in under 10 ms, and a parallel system of up to 6 inverters switches in under 20 ms, effectively eliminating noticeable power interruptions for critical loads during grid outages.

Dual independent battery ports for staged storage

Two CAN-BMS ports allow connection of two independent battery lines, enabling storage capacity to be scaled in phases as the site's energy needs grow, without replacing the whole system.

Scalable to 600 kW in parallel operation

Up to ten units can be paralleled to reach 600 kW total, though for systems above 6 inverters the manufacturer recommends an STS cabinet - this flexibility suits both small commercial projects and large-scale energy storage farms.

Flexible source integration and DC/AC coupling

The 3-in-1 interface (PV, wind, generator) plus DC and AC coupling support let existing installations be expanded without rebuilding them, a key advantage in areas with weak or unstable grids.

Tier-1 manufacturer, in business since 2005

Ginlong Solis is classified as a bankable Tier-1 manufacturer, which in practice means greater warranty financial stability and easier project financing for commercial installations based on this series.

Trade-offs
External STS cabinet required beyond 6 units

For parallel installations exceeding 6 inverters, the manufacturer requires an external switching (STS) cabinet, adding cost and complexity compared to competing solutions with a natively higher parallel limit and no extra hardware.

Moderate DC/AC oversizing ratio

The recommended maximum PV array for the 50K/60K models is 100 kW (roughly a 1.67x ratio), a moderate figure versus some competing commercial hybrids allowing up to 2x oversizing, which can limit energy yield in lower-irradiance locations.

Inverter Power Euro eff. MPPT Weight Difference
Ginlong Solis 40K 40 kW 97.3% - 76.0 kg You are here
AF40K-TH 40 kW 98.3% 4 70.0 kg +1.0 pp efficiency, 6.0 kg lighter
HP3-40KS1 40 kW 98.0% 5 80.0 kg +0.7 pp efficiency, 4.0 kg heavier
GW40K-ET-10 40 kW 97.8% - 62.0 kg +0.5 pp efficiency, 14.0 kg lighter
XD40KTR 40 kW 97.5% 4 92.0 kg 16.0 kg heavier
CISION-40K-3PH 40 kW 97.5% 4 80.0 kg 4.0 kg heavier
S6-EH3P40K-H 40 kW 97.4% - 73.0 kg 3.0 kg lighter
STH-40KTL-HT 40 kW 97.3% 5 95.0 kg 19.0 kg heavier
MID 40K-HU 40 kW 97.2% - 48.0 kg 28.0 kg lighter

About the S6-EH3P-H(21A) series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

What is DC and AC coupling in the Solis S6-EH3P-H(21A) inverters and why does it matter when expanding a system?
DC coupling connects new PV strings directly to the existing hybrid inverter, while AC coupling lets you add battery storage to an already operating PV system without rebuilding it. The S6-EH3P-H(21A) supports both methods, allowing commercial and industrial installations to scale capacity in stages without replacing existing equipment or causing long downtime during expansion.
How fast does the Solis S6-EH3P-H(21A) inverter switch between grid-tied and off-grid operation?
The switchover time is under 10 ms, which is effectively unnoticeable to connected loads. This means critical equipment in commercial or industrial facilities, such as servers, cold storage, or production lines, experiences no power interruption during a grid outage. It is one of the key advantages of this series in regions with an unstable grid.
How many batteries can be connected to the Solis S6-EH3P60K-H(21A) inverter and how large a storage system can be built?
The 60 kW model has two independent battery ports, each rated for up to 84 A charge and discharge current. This lets you scale the energy storage system in stages by adding lithium-ion battery modules as the site's needs grow, without replacing the inverter. The independent ports also allow mixing battery batches or types within the same installation.
Can Solis S6-EH3P-H(21A) inverters be paralleled into larger energy storage systems?
Yes, the series supports parallel operation up to 600 kW of combined power. For systems exceeding 6 units, Solis recommends using the STS switch cabinet to coordinate multiple inverters. This flexibility means the same model can be used in a small commercial project as well as in a large-scale energy storage farm.
Does the Solis S6-EH3P-H(21A) series perform well in harsh outdoor conditions and low temperatures?
The inverters operate across a temperature range of -25°C to +60°C, allowing outdoor installation in most climates without additional room heating or cooling. Self-consumption under 35 W reduces energy losses during nighttime standby. The transformerless design and industrial-grade enclosure further improve durability in commercial and industrial deployments.
What do the AI integration and VPP readiness offer in the Solis S6-EH3P-H(21A) inverters?
Built-in AI features let the inverter automatically optimize battery charging and discharging based on variable electricity tariffs, maximizing the storage system's return on investment. VPP (Virtual Power Plant) readiness allows the installation to join a virtual power plant and participate in flexibility markets, which can generate additional revenue for the owner of a commercial or industrial site.