Skip to main content

Ginlong Solis 18K

18 kW Hybrid Three-phase Battery-ready
Datasheet PDF
Rated AC (kW)
18.00
Typical for its class
Euro eff. (%)
97.0
Weak · bottom 10%
MPPT
2
Typical · median 2
Max DC (V)
1000
Typical · median 1000 V
Weight (kg)
42.0
Typical · median 38.0 kg
Warranty (yrs)
-
Not published

The Solis S6-EH3P-NV-YD-L series consists of three-phase hybrid inverters designed for large-scale residential and commercial solar installations paired with battery storage. The defining feature of this lineup is compatibility with low-voltage 48V batteries, which significantly widens the pool of available storage units on the market and simplifies integration with existing installations. These inverters address the problem of power interruptions through seamless on/off-grid switching and PV-only off-grid operation, a critical advantage in regions with an unstable grid. The series also stands out for its support of parallel operation of multiple units, allowing power and storage capacity to scale alongside a growing household or business without replacing existing equipment. An IP66-rated enclosure enables outdoor mounting even in harsh weather conditions, giving installers greater freedom in choosing the installation site. The inverter additionally offers native compatibility with EMS and VPP platforms, along with SG-ready control for heat pumps, making it an appealing choice for anyone planning a comprehensive home electrification strategy. This is a solution built for installers seeking flexibility, reliability, and readiness for a customer's future energy needs.

Ranking

623 inverters from 12 to 30 kW
Metric This inverter Median Position in class Rank in class
European efficiency 97.0% 98.0% Weak · bottom 10% 396
MPPT trackers 2 2 Typical 168
Max DC input voltage 1000 V 1000 V Typical 229
Weight per kW 2.3 1.8 Typical 394
Warranty - 5 yrs Not published -
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 18 kW Continuous output
Max apparent power 18.00 kVA
Phases Three-phase
Nominal AC voltage 400 V
Max AC current 27.3 A
Grid frequency 50 Hz
Power factor 0.8 leading - 0.8 lagging
Harmonic distortion (THD) 3.0 %
Max DC input power 28.80 kW DC/AC ratio 1.60
Max DC voltage 1000 V Caps the string length
MPPT voltage range 200 to 850 V
Start-up voltage 160 V
MPPT trackers 2
European efficiency 97.0 % Weighted across part loads
Max efficiency 97.5 % Best single operating point
Battery port Yes
Battery voltage 40-60 V
Grid-forming Yes
Dimensions 660 × 430 × 305 mm Height × width × depth
Weight 42.0 kg 2.3 kg per kW
Enclosure IP66
Cooling forced-air
Noise 65 dB
Operating temperature -25 to 60 °C
Max humidity 100 %
Max altitude 4000 m
Interfaces Wi-FiEthernetBluetoothDisplay
Protocols WIFILANBluetoothCAN-BMSCAN-ParallelRS485-MeterRS485DRMDIDO2G/3G/4G (optional)
Protection AFCIDC switchSurge protection
Certifications EN 50549-1/-10VDE 4105VDE 0124NRS 097-2-1IEC 62116IEC 61727IEC 60068IEC 61683EN 50530EN 50438LCEI 0-21IEC/EN 62109-1/-2IEC/EN 61000-6-1/-2/-3/-4

Pros and cons

5 positive · 3 caution
What owners get
High peak efficiency of 97.6%

The inverter reaches a maximum conversion efficiency of 97.6%, which is competitive against other three-phase low-voltage hybrid inverters in the 8-15 kW class and translates into lower energy losses when charging/discharging the battery.

Seamless on/off-grid switching <10 ms

Switchover time between grid-tied and island mode is below 10 ms, effectively undetectable by most household loads, making the series a credible alternative to dedicated UPS units in regions with unstable grid supply.

Parallel operation of up to 6 units

The manufacturer confirms support for parallel connection of up to 6 units of this series, allowing power and storage capacity to scale well beyond typical single-family installations without replacing already installed equipment.

Broad 48V battery compatibility

A battery voltage range of 40-60V (48V nominal) opens access to a large pool of low-voltage storage systems on the market, including popular LFP modules, easing selection and potentially lowering BoS cost compared to closed high-voltage ecosystems.

IP66 enclosure and Tier-1 manufacturer since 2005

The IP66 protection rating allows outdoor installation in harsh weather conditions, and Ginlong Solis, operating since 2005 and listed as a BNEF Tier-1 manufacturer, provides the financial and service stability typical of established, bankable brands.

Trade-offs
Standard warranty limited to 5 years

The base warranty period for this series is 5 years, shorter than some competing Tier-1 hybrid inverters (e.g., 10 years standard from certain manufacturers), though an extended warranty is available as a paid option.

Low-voltage 48V architecture limits single-unit scalability

Compared to high-voltage hybrid inverters (300-600V), a 48V low-voltage storage architecture requires higher DC currents at the same power level, increasing cable losses and limiting practical storage capacity per unit without parallel expansion.

Only 2 MPPT trackers on 8-15 kW variants

Models in the 8-15 kW range offer 2 MPPT trackers, which may be insufficient for installations with multiple roof orientations or partial shading, compared to competing three-phase hybrids offering 3-4 MPPTs in this power class.

Inverter Power Euro eff. MPPT Weight Difference
Ginlong Solis 18K 18 kW 97.0% 2 42.0 kg You are here
H2-18K-LT2 18 kW 98.0% 2 53.0 kg +1.0 pp efficiency, 11.0 kg heavier
HESP48180SH3 18 kW 97.5% 3 59.5 kg +0.5 pp efficiency, +1 MPPT, 17.5 kg heavier
WIT 18K-HU 18 kW 97.0% 2 55.0 kg 13.0 kg heavier
S6-EH1P18K03-NV-YD-L 18 kW 97.0% 3 55.5 kg +1 MPPT, 13.5 kg heavier
SUN-18K-SG05LP3-EU-SM2 18 kW 97.0% 2 51.9 kg 9.9 kg heavier
HESP48180S380-H 18 kW 97.0% 3 64.7 kg +1 MPPT, 22.7 kg heavier
SUN-18K-SG01LP2-US-AM3-P 18 kW 96.5% 3 61.5 kg -0.5 pp efficiency, +1 MPPT, 19.5 kg heavier
SUN-18K-SG01LP1-EU-AM3-P 18 kW 96.5% 3 59.8 kg -0.5 pp efficiency, +1 MPPT, 17.8 kg heavier

About the S6-EH3P-NV-YD-L series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

Which batteries are compatible with the Solis S6-EH3P-NV-YD-L inverter?
The S6-EH3P-NV-YD-L series works with low-voltage 48V battery storage, within a battery voltage range of roughly 40 to 60 V. This allows connection of batteries from multiple manufacturers communicating via CAN or RS485, giving installers more flexibility than high-voltage systems and making it easier to match storage capacity to a specific project.
Does the Solis S6-EH3P-NV-YD-L inverter keep working during a grid outage?
Yes, the unit provides seamless on-grid to off-grid switching, so the home installation does not lose power when grid voltage drops out. The inverter can also run in island mode, powering loads directly from the PV array and battery, which is especially useful in regions with frequent grid interruptions.
How many Solis S6-EH3P-NV-YD-L inverters can be combined in one installation?
The series supports parallel operation of multiple units, letting installers link several inverters into one system and gradually scale power and storage capacity as a household's or business's energy needs grow. This is convenient for investors who want to start with a smaller system and expand later without replacing existing equipment.
Can the S6-EH3P-NV-YD-L inverter be installed outdoors?
Yes, the enclosure has an IP66 rating, meaning full protection against dust and powerful water jets from any direction. The inverter can therefore be mounted on a building facade, in a garage, or in another outdoor location, even in humid or rainy climates, giving installers more freedom in choosing the mounting site.
Is the Solis S6-EH3P-NV-YD-L inverter compatible with EMS systems and heat pumps?
Yes, the unit offers native support for EMS and VPP systems, plus SG-ready heat pump control. This lets the inverter integrate with smart home energy management to optimize use of PV-generated electricity, which matters for homeowners planning full electrification of their heating system.
What are the efficiency and key specifications of the Solis S6-EH3P-NV-YD-L inverter?
Depending on the power variant (8K, 10K, 12K, 15K), the inverters reach a maximum efficiency of up to 97.6 percent with a maximum DC input voltage of 1000 V and two MPPT inputs. Communication runs over CAN, RS485, and Ethernet, with optional Wi-Fi or LTE, while monitoring and control are handled through a 7-inch LCD display or a mobile app.