Skip to main content

Ginlong Solis 10K

10 kW Hybrid Single-phase Battery-ready
Datasheet PDF
Rated AC (kW)
10.00
Typical for its class
Euro eff. (%)
96.1
Weak · bottom 4%
MPPT
2
Typical · median 2
Max DC (V)
500
Weak · bottom 10%
Weight (kg)
25.8
Typical · median 27.0 kg
Warranty (yrs)
-
Not published

The S7-EH1P(8-12)K02-NV-YD-L series is a single-phase, low-voltage hybrid inverter built for residential installations where flexibility and operational safety matter equally. The unit stands out with its wide compatibility with third-party batteries, so installers are not locked into a single storage ecosystem and can select components that best fit a project's budget or technical requirements. A major advantage is battery and grid terminal temperature monitoring, which detects poor connections or installation faults before they lead to overheating or fire - a direct answer to one of the most common failure points in storage systems. The inverter also delivers on/off-grid switching in under 4 ms, meaning homeowners experience virtually no interruption during a grid outage. For installers, the side-opening enclosure, similar to a distribution box, significantly speeds up installation and servicing, while the 4.3-inch touchscreen enables full system setup in under 5 minutes. On top of that, 200% overload capability for 10 seconds makes it easier to start demanding loads like motors, pumps, or air conditioners, and built-in Ethernet ensures fast connectivity with VPP platforms and EMS systems. This is a solid choice for installers looking for a versatile, durable, and easy-to-service inverter for single-family homes.

Ranking

839 inverters from 6 to 12 kW
Metric This inverter Median Position in class Rank in class
European efficiency 96.1% 97.5% Weak · bottom 4% 577
MPPT trackers 2 2 Typical 145
Max DC input voltage 500 V 800 V Weak · bottom 10% 640
Weight per kW 2.6 3.0 Typical 323
Warranty - 5 yrs Not published -
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 10 kW Continuous output
Max apparent power 10.00 kVA
Phases Single-phase
Nominal AC voltage 230 V 187-253V
Max AC current 45.5 A
Grid frequency 50 Hz
Power factor >0.99 (0.8 leading - 0.8 lagging)
Harmonic distortion (THD) 3.0 %
Max DC input power 16.00 kW DC/AC ratio 1.60
Max DC voltage 500 V Caps the string length
MPPT voltage range 100 to 430 V
Start-up voltage 100 V
MPPT trackers 2 2 strings each
Max input current per MPPT 21.0 A Must exceed the panel's Imp
Max short-circuit current per MPPT 50.0 A Must exceed the panel's Isc
European efficiency 96.1 % Weighted across part loads
Max efficiency 97.5 % Best single operating point
Battery port Yes
Battery voltage 40-60V
Grid-forming Yes
Dimensions 519 × 375 × 228 mm Height × width × depth
Weight 25.8 kg 2.6 kg per kW
Enclosure IP66
Cooling forced-air
Noise 50 dB
Operating temperature -25 to 60 °C
Max humidity 100 %
Max altitude 4000 m
Interfaces Wi-FiEthernetBluetoothDisplay
Protocols WIFILANBluetoothCAN-BMSCAN-ParallelRS485-MeterRS485DRMDIDO4G
Protection AFCIDC switchSurge protection
Certifications IEC 62116IEC 61727IEC 60068IEC 61683EN 50530EN 50549-1/-10IEC/EN 62109-1/-2IEC 61000-6-1/-2/-3/-4

Pros and cons

5 positive · 2 caution
What owners get
Broad third-party battery compatibility

The inverter is not locked into a single energy storage ecosystem - installers can select a battery from the compatible products list across multiple manufacturers, optimizing cost and component availability for a given project.

Terminal temperature monitoring

Temperature sensors on battery and grid terminals detect loose connections or installation errors before overheating occurs, meaningfully reducing one of the most common failure and fire-risk causes in residential energy storage systems.

Sub-4 ms on/off-grid switchover

A switchover time under 4 ms means homeowners experience no perceptible power interruption during a grid outage - a performance level comparable to top-tier UPS systems rather than typical hybrid PV inverters.

Side-opening enclosure and fast setup

A switchgear-style design with side access to terminals cuts installation and service time, while system configuration takes under 5 minutes thanks to the 4.3-inch touchscreen - a meaningful operational advantage for installers billed on labor hours.

200% overload capacity and built-in Ethernet for VPP/EMS

A 200% overload capability for 10 seconds enables smooth startup of motors, pumps, or air conditioners, and the built-in Ethernet port provides native integration with VPP platforms and EMS systems without extra communication modules.

Trade-offs
Standard warranty shorter than peers

Solis offers a standard 5-year warranty on this low-voltage hybrid series (extendable to 10-20 years for an extra fee), while some tier-1 peer comparables (e.g., Huawei, Sungrow) provide a 10-year base warranty at no additional cost - raising total cost of ownership for the end customer.

Battery warranty tied to manufacturer's approved list

Despite broad third-party battery compatibility, Solis requires selecting a battery from its own approved compatibility list to keep the inverter warranty valid - using an unapproved battery model, even if technically compatible, can void coverage.

Inverter Power Euro eff. MPPT Weight Difference
Ginlong Solis 10K 10 kW 96.1% 2 25.8 kg You are here
SE10000H 10 kW 99.0% - 19.6 kg +2.9 pp efficiency, 6.2 kg lighter
SigenStor Neo EC 10.0 TP 10 kW 98.7% - 30.0 kg +2.6 pp efficiency, 4.2 kg heavier
Sigen Hybrid 10.0 TP2 10 kW 98.5% 2 19.5 kg +2.4 pp efficiency, 6.3 kg lighter
HYX-H10K-HSA2 10 kW 98.2% - 38.0 kg +2.1 pp efficiency, 12.2 kg heavier
HYX-H10K-HT 10 kW 98.2% 2 34.0 kg +2.1 pp efficiency, 8.2 kg heavier
MOD 10KTL3-XH 10 kW 98.1% 2 14.0 kg +2.0 pp efficiency, 11.8 kg lighter
MOD 10KTL3-HU 10 kW 98.1% 3 20.0 kg +2.0 pp efficiency, +1 MPPT, 5.8 kg lighter
SUN2000-10KTL-M1 10 kW 98.1% 2 17.0 kg +2.0 pp efficiency, 8.8 kg lighter

About the S7-EH1P(8-12)K02-NV-YD-L series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

Does the Solis S7-EH1P(8-12)K02-NV-YD-L inverter work with third-party batteries, not just Solis batteries?
Yes, the S7-EH1P(8-12)K02-NV-YD-L series is designed for broad compatibility with third-party batteries via CAN/RS485 communication. This means installers aren't locked into a single energy storage ecosystem and can choose the battery that's optimal in price or specification for a given project. Before purchase, it's worth checking Solis's current approved battery list for your market, since installing an unapproved battery can void the inverter warranty.
How does the battery and grid terminal temperature monitoring work on this inverter?
The inverter continuously measures the temperature at the battery and grid connection terminals, which helps detect loose connections or installation errors before they lead to overheating or fire. This is one of the most common causes of failure in residential energy storage systems, so this feature meaningfully improves operating safety, especially in setups combining batteries from different manufacturers.
Will homeowners notice a power interruption during a grid outage?
Practically not. The inverter switches between grid-tied and off-grid operation in under 4 milliseconds, faster than the typical response time of most household devices such as appliances or electronics. As a result, the power interruption is unnoticeable to residents, and critical equipment like refrigerators or routers won't shut down or reset.
How long does it take to install and configure the S7-EH1P(8-12)K02-NV-YD-L inverter?
The side-opening enclosure, resembling a distribution panel, significantly cuts installation and service time by giving direct access to terminals without removing the whole cover. System configuration itself can be completed in under 5 minutes thanks to a 4.3-inch touchscreen with an intuitive menu, reducing the workload for installers commissioning multiple systems per day.
Can this inverter handle the startup surge from a pump, air conditioner, or similar high-inrush load?
Yes, the unit offers 200% overload capacity for 10 seconds, which covers the high inrush current typical of pump motors, air conditioners, or compressors. This means the inverter won't trip on a momentary load spike, a common issue in installations with high-starting-power equipment, especially homes with a pool or an AC system.
Can the S7-EH1P(8-12)K02-NV-YD-L be connected to VPP platforms and EMS systems?
Yes, the unit includes a built-in Ethernet port that provides stable, fast connectivity to virtual power plant (VPP) platforms and energy management systems (EMS). This enables remote monitoring, firmware updates, and participation in energy optimization or grid feed-in programs without needing additional communication modules.