Skip to main content
FoxESS V75

FoxESS V75

75 kW Grid-tie Three-phase
Datasheet PDF
Rated AC (kW)
75.00
Typical for its class
Euro eff. (%)
98.1
Typical · median 98.2%
MPPT
-
Not published
Max DC (V)
1100
Typical · median 1100 V
Weight (kg)
50.0
Strong · 25.0 kg below median
Warranty (yrs)
-
Not published

The V Series is a lineup of three-phase FoxESS inverters built for commercial installations and larger residential systems, where both performance and resilience under demanding conditions matter. What sets this series apart is real-time PV string monitoring, which detects drops in performance of individual module strings before they translate into real energy losses - a major advantage when tracking yield across large rooftop or ground-mount arrays. The inverters feature a PID recovery function that limits panel degradation caused by potential-induced degradation, helping modules retain efficiency over a longer lifetime. System safety is reinforced by built-in AFCI arc-fault protection, which detects dangerous DC-side arc faults. An enclosure rated IP66 with C5 anti-corrosion protection allows outdoor installation even in coastal or industrial environments without extra enclosures. The series spans models from 30 to 75 kW, making it easy to match a unit to project scale without losing configuration flexibility. This is a solution built for installers looking for reliability when scaling larger three-phase systems.

Ranking

552 inverters from 30 to 100 kW
Metric This inverter Median Position in class Rank in class
European efficiency 98.1% 98.2% Typical 223
MPPT trackers - 4 Not published -
Max DC input voltage 1100 V 1100 V Typical 12
Weight per kW 0.7 1.2 Strong · top 3% 16
Warranty - 5 yrs Not published -
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 75 kW Continuous output
Max apparent power 75.00 kVA
Phases Three-phase
Nominal AC voltage 400 V
Max AC current 114.0 A
Grid frequency 50 Hz Range 45~55 / 55~65
Power factor 0.8 leading to 0.8 lagging
Harmonic distortion (THD) 3.0 %
Max DC input power 150.00 kW DC/AC ratio 2.00
Max DC voltage 1100 V Caps the string length
MPPT voltage range 200 to 1000 V
Start-up voltage 250 V
Max input current per MPPT 40.0 A Must exceed the panel's Imp
Max short-circuit current per MPPT 50.0 A Must exceed the panel's Isc
European efficiency 98.1 % Weighted across part loads
Max efficiency 98.5 % Best single operating point
Dimensions 430 × 640 × 243 mm Height × width × depth
Weight 50.0 kg 0.7 kg per kW
Enclosure IP66
Cooling forced-air
Operating temperature -30 to 60 °C
Max humidity 100 %
Max altitude 4000 m
Interfaces Wi-FiEthernetDisplay
Protocols RS485USBWi-FiLAN
Protection AFCIDC switchSurge protection
Certifications EN50549-1

Pros and cons

5 positive · 2 caution
What owners get
Real-time PV string-level monitoring

The feature tracks current on each PV string individually, detecting output drops from a single string (shading, fault) before they affect total system yield. In large rooftop and ground-mount installations in the 30-75 kW range, this significantly simplifies diagnostics and yield reconciliation.

PID recovery function

Built-in PID recovery mitigates voltage-induced potential degradation, a more frequent issue in three-phase systems with higher system voltage than in small single-phase setups. This helps modules retain their nominal efficiency for longer.

AFCI arc-fault protection

DC-side arc-fault detection is a safety feature increasingly mandated for larger commercial installations across the EU - FoxESS integrates it natively without requiring add-on modules.

IP66 enclosure and C5 anti-corrosion rating

Per the manufacturer's datasheet, the inverter operates from -30 to 60°C and 0-100% humidity without condensation; combined with IP66/C5, this allows outdoor installation in coastal and industrial environments without extra protective enclosures - an advantage over many competitors limited to IP65.

BNEF Tier 1 status

FoxESS appears on BloombergNEF's Tier 1 list for energy storage manufacturers (Q4 2024 announcement), a bankability indicator widely used by banks and investors when financing larger commercial PV projects.

Trade-offs
Shorter brand track record

FoxESS was founded in 2019, giving it a markedly shorter track record than peers in this power class, such as SMA (since 1981) or Huawei/Sungrow, which have been established in PV for over a decade longer. For investors assessing long-term service risk on 30-75 kW installations over a 20-25 year horizon, this is a factor worth weighing.

BNEF Tier 1 status applies to energy storage, not PV inverters

FoxESS's official BNEF Tier 1 recognition is in the 'Energy Storage Manufacturers' category, not the separate 'Power Inverter Tier 1' list on which GoodWe or Sofar appear. Bankability claims for the V Series as a PV inverter are therefore not directly backed by this specific BNEF list.

Alternatives

All FoxESS inverters
Inverter Power Euro eff. MPPT Weight Difference
FoxESS V75 75 kW 98.1% - 50.0 kg You are here
C6-75K-T6-40 75 kW 98.5% - 93.0 kg +0.4 pp efficiency, 43.0 kg heavier
PVM-75-TL 75 kW 98.5% 12 83.0 kg +0.4 pp efficiency, 33.0 kg heavier
GW75KBF-MT 75 kW 98.4% 4 65.0 kg +0.3 pp efficiency, 15.0 kg heavier
ASW75K-LT 75 kW 98.4% - 86.0 kg +0.3 pp efficiency, 36.0 kg heavier
HSNV75K-G02 75 kW 98.4% 4 85.0 kg +0.3 pp efficiency, 35.0 kg heavier
GW75K-MT 75 kW 98.3% 4 70.0 kg 20.0 kg heavier
S6-GC75K-LV 75 kW 98.3% - - Similar on paper
SUN-75K-G03 75 kW 98.3% - 81.0 kg 31.0 kg heavier

About the V Series series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

How does PV string monitoring in the FoxESS V Series differ from standard inverter monitoring?
A standard inverter only shows total system output, while the V Series monitors each PV string independently in real time. This lets installers or owners quickly spot that a single string is underperforming due to shading, a damaged cable, or a faulty module, instead of noticing lower yield only months later on the energy bill.
Can FoxESS V Series inverters be installed outdoors near the coast?
Yes, the enclosure has an IP66 rating and C5 anti-corrosion certification, meaning it resists moisture, dust, and aggressive environments, including salt mist typical of coastal areas. No extra protective housing or canopy is required, which simplifies installation on facades of industrial buildings or warehouses near the shore.
What is PID recovery in FoxESS V Series inverters and does it actually extend panel lifespan?
PID degradation is a power loss caused by a voltage potential difference between the cells and the module frame, particularly common in large systems with long strings. The inverter automatically detects and corrects this polarization at night, when panels aren't producing power. In practice, this limits long-term power loss in the modules, though the actual impact depends on panel quality and installation conditions.
Which FoxESS V Series model should I choose for a commercial installation around 50 kW?
The V Series spans 30 to 75 kW (including V30, V33, V36, V40, V50, V60, and V75), so for a roughly 50 kW installation the V50 is the best match, allowing full use of the PV array's power without significantly oversizing the inverter. The exact model should still be confirmed with a system designer based on string count and layout.
Is AFCI arc-fault protection on V Series inverters legally required?
In many markets, including parts of Europe, AFCI protection is increasingly required or recommended for commercial installations due to fire risk from damaged DC connections. V Series inverters include this protection as a factory-built feature, so installers don't need to add an external AFCI module, which reduces installation time and overall system cost.
Are FoxESS V Series inverters suitable for large ground-mount installations, or only rooftop systems?
The V Series is designed for both rooftop and larger ground-mount installations. Real-time PV string monitoring is especially useful in ground-mount systems, where panels are spread over a large area and individual rows are harder to inspect physically - a faulty string can be identified remotely without sending a crew on-site.