Skip to main content
FoxESS R100-G2

FoxESS R100-G2

100 kW Grid-tie Three-phase
Datasheet PDF
Rated AC (kW)
100.00
Strong · top 8%
Euro eff. (%)
98.2
Typical · median 98.2%
MPPT
9
Strong · top 14%
Max DC (V)
1100
Typical · median 1100 V
Weight (kg)
90.0
Typical · median 75.0 kg
Warranty (yrs)
-
Not published

The FoxESS R Series (G2) is a lineup of three-phase commercial and industrial inverters ranging from 75 to 136 kW, built for installations where rugged reliability and getting the most out of every PV string really matter. The series tackles a common pain point in large rooftop and ground-mount systems: cell degradation caused by the PID effect and the difficulty of quickly isolating a fault on a single string, both of which make servicing and upkeep far more straightforward. The inverter features a PID Recovery function that automatically detects and corrects voltage-induced panel degradation, extending module lifespan and keeping energy yield stable over time. Another standout element is real-time PV string monitoring, which flags anomalies immediately and helps minimize production downtime. For installers and investors focused on safety, the optional AFCI function provides protection against arc faults. Everything is housed in an IP66-rated enclosure with smart air cooling, allowing operation across a wide temperature and humidity range, even at high altitudes. This makes it a strong fit for installation companies handling commercial-scale projects, where high system uptime and low servicing costs translate directly into better project returns.

Ranking

552 inverters from 30 to 100 kW
Metric This inverter Median Position in class Rank in class
European efficiency 98.2% 98.2% Typical 186
MPPT trackers 9 4 Strong · top 14% 33
Max DC input voltage 1100 V 1100 V Typical 12
Weight per kW 0.9 1.2 Typical 131
Warranty - 5 yrs Not published -
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 100 kW Continuous output
Max apparent power 110.00 kVA
Phases Three-phase
Nominal AC voltage 400 V 320~460
Max AC current 166.7 A
Grid frequency 50 Hz Range 45~55/55~65
Power factor 0.8 Leading ~ 0.8 Lagging
Harmonic distortion (THD) 3.0 %
Max DC input power 200.00 kW DC/AC ratio 2.00
Max DC voltage 1100 V Caps the string length
MPPT voltage range 200 to 1000 V
Start-up voltage 250 V
MPPT trackers 9 2 strings each
Max input current per MPPT 40.0 A Must exceed the panel's Imp
Max short-circuit current per MPPT 50.0 A Must exceed the panel's Isc
European efficiency 98.2 % Weighted across part loads
Max efficiency 98.6 % Best single operating point
Dimensions 630 × 975 × 360 mm Height × width × depth
Weight 90.0 kg 0.9 kg per kW
Enclosure IP66
Cooling forced-air
Operating temperature -30 to 60 °C
Max humidity 100 %
Max altitude 4000 m
Interfaces Wi-FiEthernetDisplay
Protocols RS485USBWi-FiLAN
Protection AFCIDC switchSurge protection
Certifications IEC 62109IEC 61727IEC 62116IEC 60068IEC 61683IEC 61000-6-3EN 50549

Pros and cons

5 positive · 2 caution
What owners get
Max. efficiency of 98.6%

The inverter reaches a maximum efficiency of 98.6% and a European efficiency of 98.2% (source: EN RG2 Datasheet V1.3), placing it on par with top-tier three-phase solutions in the 75-136 kW commercial segment.

Up to 9 MPPT trackers per unit

A configuration with 9 independent MPPT trackers (R75-G2 model) enables individual optimization of multiple strings with different orientations, reducing losses under partial shading and simplifying design for irregular industrial roofs.

Wide operating range of -30…60°C

An operating temperature range of -30°C to 60°C (with derating above 50°C) and installation altitude up to 4000 m (derating above 3000 m) ensure stable operation in extreme climates, where competing models are often limited to 45-50°C.

PID Recovery and string-level monitoring

A built-in PID Recovery function automatically corrects cell voltage degradation, while real-time PV string monitoring allows fast fault localization without an on-site service visit, directly cutting OPEX for large commercial installations.

Flexible connectivity and remote monitoring

The series offers RS485, USB, Wi-Fi+LAN, and optional 4G with Bluetooth, giving installers multiple integration options with SCADA/monitoring systems without needing additional third-party communication modules.

Trade-offs
Inconsistent power range documentation

The Ukrainian datasheet version (V1.1, 20251226) lists a power range of 75-110 kW, while most official sources (EN, IT, BR) state 75-136 kW including the R136-G2 model - this documentation inconsistency can make it harder for investors to reliably compare offerings across markets.

AFCI is optional, not standard

Arc-fault protection (AFCI) is an optional feature rather than a default inclusion - compared to some tier-1 competitors that bundle AFCI as standard in the commercial segment, this may mean an added cost or a conscious upsell decision for the investor.

Alternatives

All FoxESS inverters
Inverter Power Euro eff. MPPT Weight Difference
FoxESS R100-G2 100 kW 98.2% 9 90.0 kg You are here
100 NX3 M8 100 kW 98.8% - - +0.6 pp efficiency
SUN2000-100KTL-M2 100 kW 98.6% 10 93.0 kg +0.4 pp efficiency, +1 MPPT, 3.0 kg heavier
SUN2000-100KTL-M1 (@480 V) 100 kW 98.6% 10 90.0 kg +0.4 pp efficiency, +1 MPPT
M100_210 100 kW 98.6% 1 67.0 kg +0.4 pp efficiency, -8 MPPT, 23.0 kg lighter
SG110CX 100 kW 98.5% 9 89.0 kg 1.0 kg lighter
Sunny Highpower PEAK3 SHP 100-21 100 kW 98.5% 1 99.0 kg -8 MPPT, 9.0 kg heavier
Sunny Highpower Storage SHPS 100-21 100 kW 98.5% - 99.0 kg 9.0 kg heavier
Solis-100K-5G 100 kW 98.5% 9 82.0 kg 8.0 kg lighter

About the R Series (G2) series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

What models and power ratings does the FoxESS R Series (G2) cover?
The R Series (G2) includes six three-phase commercial inverter models: R75-G2, R80-G2, R100-G2, R110-G2, R125-G2, and R136-G2, with power ratings from 75 to 136 kW. This range allows the inverter to be matched to a rooftop or ground-mount installation of varying size without combining several smaller units, simplifying design and reducing DC cabling costs.
What does the PID Recovery feature do on FoxESS R Series (G2) inverters, and does it really extend panel lifespan?
PID Recovery automatically detects voltage degradation in solar cells caused by Potential Induced Degradation (PID) and corrects it overnight, when the plant is not generating power. This limits permanent power loss in modules, especially in utility-scale installations exposed to moisture and high system voltages, resulting in higher and more stable energy yield over the system's lifetime.
Is the AFCI feature on the R Series (G2) included by default, or does it need to be enabled separately?
Arc fault circuit interrupter (AFCI) protection on the FoxESS R Series (G2) is an optional feature, available for activation depending on local code requirements and project design. AFCI detects dangerous arc faults in DC circuits and automatically disconnects the system, significantly improving fire safety, particularly on large commercial rooftop installations with long PV strings.
How does real-time PV string monitoring simplify maintenance on a large installation?
String monitoring lets a technician view the parameters of each string individually, without needing physical measurements on the roof or in the field. This means a fault on a single string, such as soiling or a damaged module, is visible remotely in the monitoring dashboard immediately, rather than only after total plant output drops. This shortens service response time and reduces production losses.
What weather and temperature conditions can the FoxESS R Series (G2) inverter operate in?
An IP66-rated enclosure combined with intelligent forced-air cooling allows the inverter to operate across a temperature range of -30°C to 60°C and in high humidity without condensation. These ratings support outdoor installation, including in harsher climates and at higher altitudes, without requiring an additional protective canopy or enclosure.
What type of projects suit the FoxESS R Series (G2), and is the brand a safe choice for a commercial installation?
The R Series (G2) is designed for installer companies delivering commercial and industrial projects ranging from tens of kilowatts to over a hundred kilowatts, where system uptime and low service costs matter most. FoxESS is a tier-1 manufacturer with an established market position, which means easier access to warranty service, spare parts, and technical support compared with lesser-known brands.