The TRIO-TL-OUTD series comprises FIMER three-phase string inverters designed for commercial installations with varied roof geometry and panel orientation. The defining feature is the dual, independent MPPT system, which lets installers connect two separate PV sub-arrays - for example facing east and west - and track their maximum power point separately, avoiding the energy losses typical of a single tracker. Thanks to the wide input voltage range, installers gain freedom in sizing string lengths, which shortens design time and reduces the number of wiring variants needed. The unit operates on a transformerless, true three-phase bridge topology, resulting in a flat efficiency curve across the entire load range. The IP65-rated enclosure and fan-free convection cooling allow the inverter to be mounted outdoors in demanding environmental conditions, without the failure risks tied to dust or moisture and without added operating noise. Installation and servicing are simplified by a detachable wiring box with optional DC/AC disconnect switches, fuses, and surge arresters, available in several configurations matched to local grid standards. The series suits installers working on commercial buildings, warehouses, and agricultural sites, where configuration flexibility and long-term reliability matter most.
Ranking
Specifications
Pros and cons
Two independent MPPT trackers allow connecting strings with different orientations (e.g., east-west) and tracking their maximum power point separately, reducing mismatch losses typical of a single shared tracker on complex roof geometries.
IP65 protection rating (equivalent to NEMA 4X) combined with fanless convection cooling enables outdoor installation in harsh environments, eliminating fan-failure risk and operating noise - a key advantage for commercial and warehouse sites.
Maximum DC input voltage up to 1000 V and a broad MPPT operating range give installers flexibility in string length design, reducing the number of cabling variants needed and shortening engineering time.
A modular, removable DC/AC connection box with optional disconnect switches, fuses and surge protection devices allows the configuration to be matched to local grid codes without replacing the whole unit, simplifying field service.
An ambient temperature range of -25°C to +60°C (with derating above 50°C) supports deployment across a wide range of climates, from cold warehouses to heat-soaked industrial roof installations.
The TRIO-TL-OUTD series (launched in 2013) has been discontinued, meaning limited availability of service, spare parts, and technical support compared with currently produced Tier-1 inverters.
FIMER S.p.A. has undergone insolvency/protective restructuring proceedings in Italy, which distributors (e.g., Krannich Solar) flag as a potential risk factor for honoring warranty claims on legacy series such as TRIO-TL-OUTD.
In residential variants (5.8-8.5 kW), a DC disconnect switch is not standard and requires an additional connection-box configuration, unlike many currently produced Tier-1 inverters where this is a built-in feature.
Alternatives
About the TRIO-TL-OUTD series
These answers cover the whole series. Where a figure differs, the specification above is this model's own.