Skip to main content
FIMER TRIO-27.6-TL-OUTD

FIMER TRIO-27.6-TL-OUTD

27.6 kW Grid-tie Three-phase
Datasheet PDF
Rated AC (kW)
27.60
Strong · top 19%
Euro eff. (%)
98.0
Typical · median 98.0%
MPPT
2
Typical · median 2
Max DC (V)
1000
Typical · median 1000 V
Weight (kg)
75.0
Weak · 37.0 kg above median
Warranty (yrs)
-
Not published

The TRIO-TL-OUTD series comprises FIMER three-phase string inverters designed for commercial installations with varied roof geometry and panel orientation. The defining feature is the dual, independent MPPT system, which lets installers connect two separate PV sub-arrays - for example facing east and west - and track their maximum power point separately, avoiding the energy losses typical of a single tracker. Thanks to the wide input voltage range, installers gain freedom in sizing string lengths, which shortens design time and reduces the number of wiring variants needed. The unit operates on a transformerless, true three-phase bridge topology, resulting in a flat efficiency curve across the entire load range. The IP65-rated enclosure and fan-free convection cooling allow the inverter to be mounted outdoors in demanding environmental conditions, without the failure risks tied to dust or moisture and without added operating noise. Installation and servicing are simplified by a detachable wiring box with optional DC/AC disconnect switches, fuses, and surge arresters, available in several configurations matched to local grid standards. The series suits installers working on commercial buildings, warehouses, and agricultural sites, where configuration flexibility and long-term reliability matter most.

Ranking

623 inverters from 12 to 30 kW
Metric This inverter Median Position in class Rank in class
European efficiency 98.0% 98.0% Typical 167
MPPT trackers 2 2 Typical 168
Max DC input voltage 1000 V 1000 V Typical 229
Weight per kW 2.7 1.8 Weak · bottom 23% 464
Warranty - 5 yrs Not published -
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 27.6 kW Continuous output
Max AC power 30.00 kW Short-term output above the rating
Max apparent power 30.67 kVA
Phases Three-phase
Nominal AC voltage 400 V 320...480 V
Max AC current 45.0 A
Grid frequency 50 Hz Range 47...53 Hz / 57…63 Hz
Power factor adj. ± 0.9 with Pacr, ± 0.8 with max kVA
Harmonic distortion (THD) 3.0 %
Max DC input power 28.60 kW DC/AC ratio 1.04
Max DC voltage 1000 V Caps the string length
MPPT voltage range 200 to 950 V
Start-up voltage 430 V
MPPT trackers 2 1 string each
European efficiency 98.0 % Weighted across part loads
Max efficiency 98.2 % Best single operating point
CEC efficiency 98.0 % California Energy Commission weighting
Dimensions 1061 × 702 × 292 mm Height × width × depth
Weight 75.0 kg 2.7 kg per kW
Enclosure IP65
Cooling natural
Noise 50 dB
Operating temperature -25 to 60 °C
Max humidity 100 %
Max altitude 2000 m
Interfaces Wi-FiDisplay
Protocols RS232/485RS485WiFi
Protection DC switchSurge protection
Certifications CERCMEN 50178IEC/EN 62109-1IEC/EN 62109-2AS/NZS 3100AS/NZS 60950.1EN 61000-6-2EN 61000-6-3EN 61000-3-11EN 61000-3-12CEI 0-21CEI 0-16DIN V VDE V 0126-1-1VDE-AR-N 4105G59/3C10/11EN 50438RD 1699RD 413RD 661P.O. 12.3AS 4777BDEWNRS-097-2-1MEAIEC 61727IEC 62116Ordinul 30/2013VFR 2014

Pros and cons

5 positive · 3 caution
What owners get
Dual independent MPPT

Two independent MPPT trackers allow connecting strings with different orientations (e.g., east-west) and tracking their maximum power point separately, reducing mismatch losses typical of a single shared tracker on complex roof geometries.

IP65 enclosure, fanless cooling

IP65 protection rating (equivalent to NEMA 4X) combined with fanless convection cooling enables outdoor installation in harsh environments, eliminating fan-failure risk and operating noise - a key advantage for commercial and warehouse sites.

Wide DC input voltage range

Maximum DC input voltage up to 1000 V and a broad MPPT operating range give installers flexibility in string length design, reducing the number of cabling variants needed and shortening engineering time.

Removable connection box

A modular, removable DC/AC connection box with optional disconnect switches, fuses and surge protection devices allows the configuration to be matched to local grid codes without replacing the whole unit, simplifying field service.

Extended operating temperature range

An ambient temperature range of -25°C to +60°C (with derating above 50°C) supports deployment across a wide range of climates, from cold warehouses to heat-soaked industrial roof installations.

Trade-offs
Discontinued product line

The TRIO-TL-OUTD series (launched in 2013) has been discontinued, meaning limited availability of service, spare parts, and technical support compared with currently produced Tier-1 inverters.

Manufacturer warranty uncertainty

FIMER S.p.A. has undergone insolvency/protective restructuring proceedings in Italy, which distributors (e.g., Krannich Solar) flag as a potential risk factor for honoring warranty claims on legacy series such as TRIO-TL-OUTD.

No integrated DC disconnect in base version

In residential variants (5.8-8.5 kW), a DC disconnect switch is not standard and requires an additional connection-box configuration, unlike many currently produced Tier-1 inverters where this is a built-in feature.

Alternatives

All FIMER inverters
Inverter Power Euro eff. MPPT Weight Difference
FIMER TRIO-27.6-TL-OUTD 27.6 kW 98.0% 2 75.0 kg You are here
27.6K 27.6 kW 98.1% 4 34.9 kg +2 MPPT, 40.1 kg lighter
SolarEdge SE27.6K (Three Phase) 27.6 kW 98.0% - 45.0 kg 30.0 kg lighter
SE27.6K 27.6 kW 98.0% - 32.0 kg 43.0 kg lighter
PVI 28TL 28 kW - 2 56.5 kg +0.4 kW, 18.5 kg lighter
ASW27K-LT-G3 27 kW 98.2% 3 29.0 kg -0.6 kW, +1 MPPT, 46.0 kg lighter
Fronius Eco 27.0-3-S 27 kW 98.0% 1 35.7 kg -0.6 kW, -1 MPPT, 39.3 kg lighter
Fronius Verto 27.0 27 kW 97.8% 4 41.8 kg -0.6 kW, +2 MPPT, 33.2 kg lighter

About the TRIO-TL-OUTD series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

What is the maximum power output of the TRIO-TL-OUTD series inverters?
The TRIO-TL-OUTD series ranges from approximately 5.8 kW up to 27.6 kW, allowing the unit to be matched to projects of different scale - from smaller commercial sites to larger warehouses and agricultural facilities. The top model, TRIO-27.6-TL-OUTD, targets large installations with extensive PV arrays and requires properly sized grid-connection infrastructure.
Is the TRIO-TL-OUTD series still available for purchase?
No, the TRIO-TL-OUTD series has been discontinued and is no longer officially sold by FIMER. Units may still be found through distributors as remaining stock or on the secondary market. When buying such a unit, ask the seller about the remaining warranty period and the availability of service and spare parts, since manufacturer support for discontinued models is often limited.
What is the dual MPPT system in TRIO-TL-OUTD used for, and is it worth having?
Two independent MPPT trackers allow two separate strings of panels to be connected, for example facing east and west or installed at different tilt angles, and track their maximum power point separately. This avoids the energy losses that occur when strings with different irradiance conditions share a single tracker. The feature is especially useful on commercial roofs with complex geometry.
Can the TRIO-TL-OUTD inverter be mounted outdoors?
Yes, the IP65-rated enclosure and fanless convection cooling allow direct outdoor installation, even in harsh environmental conditions involving dust, humidity, or temperature swings. The absence of fans also means the unit produces no additional noise, which matters when mounting near offices or occupied spaces.
How does the transformerless design of TRIO-TL-OUTD differ from a transformer-based inverter?
The transformerless design with a full three-phase bridge delivers higher, flatter efficiency across a wide load range compared to traditional transformer-based inverters, while also being lighter and more compact. The trade-off is typically the lack of full galvanic isolation, so the installation requires proper grounding and protection in line with local grid codes.
What DC/AC protection options can be fitted in the TRIO-TL-OUTD connection box?
The removable connection box is available in several configurations with optional DC and AC disconnect switches, fuses, and surge protection devices, allowing the system to be tailored to local grid operator requirements. This design also simplifies servicing, since a technician can detach the box without removing the entire inverter body.