Skip to main content

FIMER PVS-33-TL

33 kW Grid-tie Three-phase
Datasheet PDF
Rated AC (kW)
33.00
Weak · bottom 3%
Euro eff. (%)
98.2
Typical · median 98.2%
MPPT
-
Not published
Max DC (V)
1100
Typical · median 1100 V
Weight (kg)
50.0
Typical · median 75.0 kg
Warranty (yrs)
-
Not published

The FIMER PVS-TL series comprises three-phase string inverters built for commercial and industrial installations, where both mounting flexibility and reliable operation under heavy rooftop and facility loads matter most. The compact, lightweight design allows for fast installation even in hard-to-reach locations, without the need for additional lifting equipment. These units stand out with single string current monitoring, enabling immediate diagnostics at the individual module string level and shortening service response times. The optional integrated arc fault circuit interrupter (AFCI) boosts fire safety for the installation, which is especially important in large-area commercial facilities. The built-in export power limitation function allows the system's output to be matched to grid operator requirements without extra external devices. The series offers multiple MPPT inputs, giving designers greater freedom when laying out strings under uneven shading or varying roof orientations. Thanks to remote communication and integration with a monitoring platform, installers and facility managers can track system performance continuously and quickly spot deviations from normal operation. This is a solution for installation companies seeking proven European technology with low servicing costs throughout the installation's entire lifecycle.

Ranking

552 inverters from 30 to 100 kW
Metric This inverter Median Position in class Rank in class
European efficiency 98.2% 98.2% Typical 186
MPPT trackers - 4 Not published -
Max DC input voltage 1100 V 1100 V Typical 12
Weight per kW 1.5 1.2 Typical 381
Warranty - 5 yrs Not published -
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Price offers

1 from shops we track
Shop Country Price Per kW Stock Offer updated Link to shop
eshop.sunfin.cz Czechia 91 355 Kč incl. VAT 2 768.33 Kč/kW In stock 13h ago Visit shop

Specifications

Open datasheet PDF
Rated AC power 33 kW Continuous output
Max AC power 36.30 kW Short-term output above the rating
Max apparent power 36.30 kVA
Phases Three-phase
Max AC current 55.1 A
Grid frequency 50 Hz Range 47-53 Hz / 57-63 Hz
Power factor >0.995; 0...1 inductive/capacitive
Harmonic distortion (THD) 3.0 %
Max DC input power 48.00 kW DC/AC ratio 1.46
Max DC voltage 1100 V Caps the string length
MPPT voltage range 460 to 850 V
Start-up voltage 430 V
Max input current per MPPT 26.0 A Must exceed the panel's Imp
Max short-circuit current per MPPT 40.0 A Must exceed the panel's Isc
European efficiency 98.2 % Weighted across part loads
Max efficiency 98.4 % Best single operating point
Dimensions 675 × 592 × 228 mm Height × width × depth
Weight 50.0 kg 1.5 kg per kW
Enclosure IP65
Cooling forced-air
Operating temperature -25 to 60 °C
Max humidity 100 %
Max altitude 4000 m
Interfaces Wi-FiEthernetDisplay
Protocols EthernetWLANRS-485Modbus TCP SunspecModbus RTU Sunspec
Protection AFCIDC switchSurge protection
Certifications CERCMIEC/EN 62109-1IEC/EN 62109-2EN 61000-6-1EN 61000-6-2EN 61000-3-11EN 61000-3-12EN 62311EN 301 489-1EN 301 489-17EN 300 328IEC 61683EN 50530IEC 62116IEC 61727AS/NZS 4777.2VDE-AR-N 4105VDE-AR-N 4110

Pros and cons

5 positive · 2 caution
What owners get
Wide power range 10-175 kW

The PVS-TL series spans from 10 kW (PVS-10-TL) up to 175 kW (PVS-175-TL), covering commercial, industrial, and large-roof installations on a single, familiar service platform.

ABB technology heritage

FIMER acquired ABB's string inverter business in 2020, meaning the PVS-TL series is built on a proven, extensively field-tested electronic platform previously used in ABB products across European markets.

Extensive MPPT inputs

Depending on the model, the series offers from 2-4 MPPTs (e.g., PVS-20/30/33-TL) up to 12 MPPTs in the 75-125 kW variants, giving significant string design flexibility under uneven shading conditions.

Optional AFCI and export power limitation

Units can be equipped with an optional arc-fault circuit interrupter (UL 1699B compliant in US variants) plus a built-in export power limitation function, eliminating the need for external control devices.

Compact, lightweight mounting design

The low unit weight allows installation without additional lifting equipment, shortening install time in hard-to-access locations such as industrial roof applications.

Trade-offs
Discontinued, limited service support

The PVS-TL series was discontinued (2021-2024) following FIMER's financial difficulties. Resellers such as Solarics list models like the PVS-10-TL and PVS-120-TL as End-of-Life, indicating limited availability of genuine spare parts and manufacturer support.

AFCI offered as optional, not standard

The arc-fault circuit interrupter is available as an optional add-on across most models (e.g., PVS-10/12.5/15-TL, PVS-20/30/33-TL) rather than standard equipment, adding cost for installations requiring enhanced fire safety.

Alternatives

All FIMER inverters
Inverter Power Euro eff. MPPT Weight Difference
FIMER PVS-33-TL 33 kW 98.2% - 50.0 kg You are here
MID 33KTL3-X 33 kW 98.5% - 29.5 kg 20.5 kg lighter
XG33KTR 33 kW 98.5% - 32.0 kg 18.0 kg lighter
V33 33 kW 98.4% - 41.0 kg 9.0 kg lighter
SG33CX 33 kW 98.3% - 50.0 kg Similar on paper
SG33T-P2-CN 33 kW 98.3% 3 25.0 kg 25.0 kg lighter
SG33CX-P2 33 kW 98.3% 3 38.0 kg 12.0 kg lighter
ASW33K-LT-G2 33 kW 98.3% - 42.0 kg 8.0 kg lighter
STT-33KTL 33 kW 98.3% 4 42.0 kg 8.0 kg lighter

About the PVS-TL series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

Are FIMER PVS-TL inverters still available for purchase?
The PVS-TL series has been discontinued from active production. FIMER went through financial difficulties and restructuring in 2023, and its assets were subsequently acquired by the McLaren Applied group. In practice, new PVS-TL units are now available mainly from distributor stock, so installers should confirm spare parts availability and long-term service support before purchasing.
How many MPPT inputs does the FIMER PVS-TL inverter have, and what does that mean for system design?
The number of MPPT inputs varies by model within the PVS-TL series, ranging from 2 on the smaller 10-15 kW units up to 12 on the larger industrial 75-125 kW models. More MPPT inputs let designers split a system into independent strings facing different orientations or experiencing different shading levels, increasing total energy yield on irregular commercial roofs and industrial buildings.
Does the PVS-TL inverter have a built-in arc fault circuit interrupter (AFCI)?
Yes, on most PVS-TL models AFCI is offered as an optional feature added to the base configuration, while US market variants often include it as standard. The detector identifies dangerous arcs, for example from damaged string connectors, and automatically disconnects the DC side, reducing fire risk on commercial buildings with large roof areas.
How does per-string current monitoring on the PVS-TL differ from standard inverter monitoring?
Standard monitoring only reports parameters for the whole inverter, while the PVS-TL measures current on each individual string separately. This lets a technician immediately see which specific module chain has stopped performing correctly, without physically checking every string on the roof. It cuts fault diagnosis time from hours to minutes, which matters on large installations on industrial halls.
Can the FIMER PVS-TL inverter limit exported power to the grid?
Yes, the PVS-TL includes a built-in export power limitation function without requiring additional external meters or controllers. This is useful when the grid operator imposes a cap on power fed back from the installation, which is common for large commercial systems connected to weaker sections of the low- or medium-voltage grid.
What are the alternatives to FIMER PVS-TL now that the series has been discontinued?
Since the PVS-TL is no longer manufactured, installers looking for comparable three-phase string inverters for commercial and industrial use typically consider manufacturers such as Huawei, SMA, Sungrow, or Fronius, which offer similar power ranges and per-string monitoring features. When replacing a failed PVS-TL unit, check MPPT voltage ranges and connector compatibility with the existing DC wiring.