Skip to main content
FIMER PVM-155-TL-US

FIMER PVM-155-TL-US

155 kW Grid-tie Three-phase
Datasheet PDF
Rated AC (kW)
155.00
Typical for its class
Euro eff. (%)
-
Not published
MPPT
-
Not published
Max DC (V)
1100
Typical · median 1100 V
Weight (kg)
93.0
Typical · median 99.0 kg
Warranty (yrs)
-
Not published

The PVM-TL-US series is an extreme high-power three-phase string inverter platform, available in four sizes from 75 kW to 155 kW, built for commercial and industrial projects on large rooftops as well as ground-mounted systems. Its main advantage is a high level of integration - built-in DC disconnects, surge protection devices, and up to 24 string connections remove the need for separate combiner boxes, cutting both installation time and logistics costs. With up to 12 independent MPPTs that can be paralleled according to project requirements, the series delivers strong shade tolerance and configuration flexibility even on irregular roof layouts or hilly ground. Installation is simplified by the double-stage conversion topology with a wide input voltage range and a NEMA 4X/4-rated enclosure that keeps DC and AC connections accessible from the outside. The inverter stands out with built-in arc fault detection (AFCI) and energy management without an external controller, streamlining self-consumption and export limitation setups. Dual Ethernet ports and the Modbus/SUNSPEC protocol ensure fast, future-proof integration with monitoring systems, including the Aurora Vision cloud platform. This makes it a strong fit for installers looking for a compact, modular string platform that reduces the number of units on large-scale installations without sacrificing design flexibility or safety.

Ranking

238 inverters from 100 to 500 kW
Metric This inverter Median Position in class Rank in class
European efficiency - 98.5% Not published -
MPPT trackers - 8 Not published -
Max DC input voltage 1100 V 1100 V Typical 113
Weight per kW 0.6 0.7 Typical 95
Warranty - 5 yrs Not published -
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 155 kW Continuous output
Max apparent power 155.00 kVA
Phases Three-phase
Nominal AC voltage 480 V
Max AC current 190.0 A
Grid frequency 60 Hz Range 57-63 Hz
Power factor 0.8 over/under excited ... 1
Harmonic distortion (THD) 3.0 %
Max DC input power 193.00 kW DC/AC ratio 1.25
Max DC voltage 1100 V Caps the string length
MPPT voltage range 555 to 850 V
Start-up voltage 430 V
Max input current per MPPT 32.0 A Must exceed the panel's Imp
Max short-circuit current per MPPT 50.0 A Must exceed the panel's Isc
Max efficiency 98.8 % Best single operating point
CEC efficiency 98.5 % California Energy Commission weighting
Dimensions 715 × 965 × 380 mm Height × width × depth
Weight 93.0 kg 0.6 kg per kW
Enclosure NEMA 4X (Power Box) / NEMA 4 (Wiring Box)
Cooling forced-air
Noise 78 dB
Operating temperature -25 to 60 °C
Max humidity 100 %
Max altitude 4000 m
Installation Outdoor only
Interfaces Wi-FiEthernet
Protocols WLANDual EthernetRS-485Modbus TCP SunspecModbus RTU Sunspec
Protection AFCIDC switchSurge protection
Certifications CERCMULUL1741:2021 (3rd Edition)UL1699 Ed.1UL1998:2022FCC (Part 15)IEEE 1547:2018IEEE 1547A:2020IEEE 1547.1:2020CAN CSA-C22.2Hawaii SRD V2.0RULE 21IEC 62477-1:2022IEC 60721-3-4:2019

Pros and cons

5 positive · 1 caution
What owners get
High unit power rating 75-155 kW

The series spans four power variants from 75 kW to 155 kW, allowing large C&I installations to be covered with fewer inverter units than typical 50-100 kW string platforms, reducing wiring complexity and service points.

Up to 12 independent MPPTs and 24 string inputs

Configuration with up to 12 MPPT trackers and 24 DC inputs provides significant flexibility for grouping strings on irregular roof pitches or uneven terrain, reducing mismatch losses compared to competing string inverters with only 4-6 MPPTs in this power class.

High integration of BoS components

Built-in DC disconnects, surge protection, and arc-fault circuit interruption (AFCI) eliminate the need for separate combiner boxes, which per FIMER shortens installation time and lowers BoS material costs on large C&I projects.

NEMA 4X/4 enclosure and up to 98.8% efficiency

NEMA 4X rating for the power compartment and NEMA 4 for the AC wiring box enable outdoor mounting in harsh conditions, while a maximum efficiency of 98.8% (FIMER datasheet) is competitive against other string platforms in this power class.

Native Modbus/SunSpec and Aurora Vision connectivity

Two Ethernet ports and native Modbus/SunSpec support without an external power management controller simplify integration with SCADA systems and the Aurora Vision cloud, lowering deployment costs for export limitation and self-consumption schemes.

Trade-offs
Manufacturer's history of financial instability

FIMER underwent debt restructuring in 2022 (receiving €45 million in funding from GeneralFinance), saw a planned €95 million investment collapse in 2023, and was acquired by McLaren Applied/Greybull Capital for roughly €26 million in December 2024. For a product typically carrying a 25-30 year linear warranty, this poses a real long-term risk to service continuity and spare-parts availability.

Alternatives

All FIMER inverters
Inverter Power Euro eff. MPPT Weight Difference
FIMER PVM-155-TL-US 155 kW - - 93.0 kg You are here
155 TL3 155 kW 98.9% 1 78.2 kg 14.8 kg lighter
150 TL3 150 kW 99.0% 1 78.2 kg -5.0 kW, 14.8 kg lighter
Sunny Highpower PEAK3 SHP 150-21 150 kW 98.8% 1 99.0 kg -5.0 kW, 6.0 kg heavier
Sunny Highpower Storage SHPS 150-21 150 kW 98.8% - 99.0 kg -5.0 kW, 6.0 kg heavier
ASW150K-LT 150 kW 98.6% 8 100.9 kg -5.0 kW, 7.9 kg heavier
MAX 150KTL3-X LV 150 kW 98.4% 10 93.0 kg -5.0 kW
S6-GC3P150K07-NV-ND 150 kW 98.3% 7 105.0 kg -5.0 kW, 12.0 kg heavier
STT-150KTL-SE 150 kW 98.3% 10 92.0 kg -5.0 kW, 1.0 kg lighter

About the PVM-TL-US series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

What is the maximum power rating of the FIMER PVM-TL-US inverter series and what applications does it suit?
The PVM-TL-US series includes four power variants ranging from 75 kW to 155 kW, allowing installers to match the inverter to the project scale without oversizing the unit count. It is designed for commercial and industrial installations, including large rooftop systems on warehouses and logistics centers as well as ground-mount solar farms, where minimizing the number of units on site matters.
Does the PVM-TL-US inverter require external DC combiner boxes?
No, thanks to its high level of integration the inverter includes built-in DC disconnects, surge protection devices, and up to 24 string inputs. This eliminates the need for separate combiner boxes, which shortens installation time, reduces the number of components to purchase, and lowers logistics costs on large-scale projects.
How many MPPT trackers does the PVM-TL-US series have and how does this help with shading tolerance?
The inverter features up to 12 independent MPPT inputs, allowing strings to be grouped and configured according to the actual layout of the array. This is a major advantage on irregular rooftops with chimneys or skylights, as well as on hilly ground-mount terrain where different array sections receive uneven irradiance.
Does the PVM-TL-US have built-in arc fault detection and export control?
Yes, the inverter includes built-in AFCI (arc fault circuit interruption) along with energy management functions that support self-consumption and export limitation without requiring an external controller. This simplifies system design and reduces the cost of additional control hardware.
What is the enclosure rating of the PVM-TL-US and is it suitable for outdoor installation?
The inverter has a NEMA 4X/4 rated enclosure, providing protection against dust and rain for direct mounting on rooftops or in ground-mount systems. All DC and AC terminations are accessible from the outside of the unit, making wiring and servicing easier without opening the full enclosure.
Which monitoring systems is the PVM-TL-US inverter compatible with?
The unit is equipped with two Ethernet ports and supports Modbus and SunSpec protocols, enabling easy integration with SCADA monitoring systems and FIMER's Aurora Vision cloud platform. This connectivity allows for remote performance monitoring, fault diagnostics, and centralized management of large-scale installations.