Skip to main content

FIMER PVI-10.0-TL-OUTD

10 kW Grid-tie Three-phase
Datasheet PDF
Rated AC (kW)
10.00
Typical for its class
Euro eff. (%)
97.1
Typical · median 97.5%
MPPT
2
Typical · median 2
Max DC (V)
900
Typical · median 800 V
Weight (kg)
41.0
Weak · 14.0 kg above median
Warranty (yrs)
-
Not published

The PVI-TL-OUTD series comprises three-phase, transformerless inverters built for commercial installations where stable energy output matters even under variable weather conditions. The standout feature of this line is its two independent MPPT trackers, which allow optimal energy harvesting from two sub-arrays oriented in different directions - an ideal solution for roofs with irregular geometry or complex shading patterns. Thanks to its wide input voltage range, the unit also performs well in installations with shorter strings, simplifying system design and reducing BoS costs. The inverter stands out for its flat efficiency curves, maintaining high performance across nearly the entire output power range rather than just at the rated point. An IP65-rated enclosure and fanless natural convection cooling ensure maintenance-free outdoor operation across a wide temperature range, minimizing failure risk and service costs. An integrated DC disconnect switch (available in -S and -FS versions), RS-485 communication, and an optional Wi-Fi logger with Modbus TCP/SunSpec support deliver full monitoring flexibility. It's a solid choice for installers looking for a reliable, versatile inverter for commercial and light industrial sites at moderate power ratings.

Ranking

839 inverters from 6 to 12 kW
Metric This inverter Median Position in class Rank in class
European efficiency 97.1% 97.5% Typical 417
MPPT trackers 2 2 Typical 145
Max DC input voltage 900 V 800 V Typical 349
Weight per kW 4.1 3.0 Weak · bottom 21% 648
Warranty - 5 yrs Not published -
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 10 kW Continuous output
Max AC power 11.00 kW Short-term output above the rating
Max apparent power 11.50 kVA
Phases Three-phase
Nominal AC voltage 400 V 320...480 V
Max AC current 16.6 A
Grid frequency 50 Hz Range 47...53 Hz / 57...63 Hz
Power factor adj. ± 0.9 with Pacr, ± 0.8 with max kVA
Harmonic distortion (THD) 2.0 %
Max DC input power 10.30 kW DC/AC ratio 1.03
Max DC voltage 900 V Caps the string length
MPPT voltage range 200 to 850 V
Start-up voltage 360 V
MPPT trackers 2 2 strings each
Max input current per MPPT 18.0 A Must exceed the panel's Imp
Max short-circuit current per MPPT 22.0 A Must exceed the panel's Isc
European efficiency 97.1 % Weighted across part loads
Max efficiency 97.8 % Best single operating point
Dimensions 716 × 645 × 224 mm Height × width × depth
Weight 41.0 kg 4.1 kg per kW
Enclosure IP65
Cooling natural
Noise 50 dB
Operating temperature -25 to 60 °C
Max humidity 100 %
Max altitude 2000 m
Installation Outdoor only
Interfaces Wi-FiDisplay
Protocols RS-485Modbus TCPSunspecWiFi
Protection DC switchSurge protection
Certifications CERCMEN 50178IEC/EN 62109-1IEC/EN 62109-2AS/NZS 3100AS/NZS 60950.1EN 61000-6-2EN 61000-6-3EN 61000-3-11EN 61000-3-12CEI 0-21CEI 0-16DIN V VDE V 0126-1-1VDE-AR-N 4105G59/3C10/11EN 50438RD 1699RD 413RD 661P.O. 12.3AS/NZS 4777IEC 61727IEC 62116BDEWMEANRS 097-2-1VFR 2014

Pros and cons

5 positive · 3 caution
What owners get
Two independent MPPT trackers

Two separate MPPT inputs allow independent handling of panel subarrays with different orientations or shading, which is especially useful on commercial rooftops with irregular geometry and non-uniform module layout.

High weighted EURO efficiency

The PVI-10.0/12.5-TL-OUTD models reach a weighted (EURO) efficiency of 97.1-97.2%, and flat efficiency curves maintain high conversion performance even at partial load, not just at the rated point.

Wide DC input voltage range

A start-up voltage of 360 V (adjustable 250-500 V) and an operating range up to 850 V with a maximum DC input of 900 V provide design flexibility for strings with fewer panels, reducing BoS costs.

Maintenance-free outdoor operation, IP65

The IP65 enclosure and fanless convection cooling eliminate moving parts prone to failure and allow outdoor installation without additional housing, reducing lifecycle service costs.

Flexible communication and monitoring

Native RS-485 communication plus an optional Wi-Fi module with Modbus TCP/SunSpec support enable integration with common SCADA systems and monitoring platforms without extra protocol converters.

Trade-offs
Discontinued since 2022

The PVI-TL-OUTD series was manufactured from 2012 to 2022 and is now discontinued by FIMER, meaning limited availability of spare parts and warranty service for existing installations.

Dated transformerless design, no hybrid features

As a 2012-era design, the series lacks energy storage support or smart-grid functions found in newer commercial inverters in this class (e.g., FIMER PVS or competing Huawei SUN2000 series), limiting its appeal for retrofitted installations.

Moderate unit power rating

The 10.0-12.5 kW power range limits use to smaller commercial installations; larger industrial projects require multiple units, increasing installation costs compared to newer string inverters with higher unit power ratings.

Alternatives

All FIMER inverters
Inverter Power Euro eff. MPPT Weight Difference
FIMER PVI-10.0-TL-OUTD 10 kW 97.1% 2 41.0 kg You are here
XG10KTR-S 10 kW 98.5% 2 13.5 kg +1.4 pp efficiency, 27.5 kg lighter
BNT010KTL 10 kW 98.2% 2 16.0 kg +1.1 pp efficiency, 25.0 kg lighter
MOD 10KTL3-X2(Pro) 10 kW 98.2% 2 14.6 kg +1.1 pp efficiency, 26.4 kg lighter
ASW10K-LT-G2 10 kW 98.2% 2 17.0 kg +1.1 pp efficiency, 24.0 kg lighter
ASW10K-LT-G2 Pro 10 kW 98.2% 2 16.0 kg +1.1 pp efficiency, 25.0 kg lighter
STT-10KTL-SE-LV 10 kW 98.2% 2 27.4 kg +1.1 pp efficiency, 13.6 kg lighter
STT-10KTL-P 10 kW 98.2% 2 23.0 kg +1.1 pp efficiency, 18.0 kg lighter
MOD 10KTL3-X 10 kW 98.1% 2 14.0 kg +1.0 pp efficiency, 27.0 kg lighter

About the PVI-TL-OUTD series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

Is the FIMER PVI-TL-OUTD inverter series still available for purchase?
The PVI-TL-OUTD series has been discontinued by FIMER and is now listed as a legacy product line. New units may still be found at some distributors as remaining stock, but for any expansion or replacement project, buyers should expect limited availability of spare parts and long-term service support. FIMER recommends current models from the PVS or TRIO lines with a similar MPPT architecture for new installations.
What do the two independent MPPT trackers on the PVI-TL-OUTD inverter offer?
The two independent MPPT trackers allow two separate strings of panels, for example facing different directions (east-west) or with different shading levels, to be connected and optimized individually. This prevents the energy losses typical of a single shared MPPT tracker, where a poorly lit string would limit the output of the entire system. It's a major advantage for commercial roofs with irregular geometry.
Can the PVI-TL-OUTD inverter be installed outdoors without a canopy?
Yes, the IP65-rated enclosure and fanless convection cooling were specifically designed for outdoor operation without additional shelter. The unit resists dust, rain, and fluctuating weather conditions, and the lack of fans eliminates the risk of cooling blockage while reducing maintenance needs, even when mounted on a facade or outdoor support structure.
How do the -S and -FS versions of the PVI-TL-OUTD differ from the standard model?
The -S and -FS versions include an integrated DC disconnect switch, meaning a built-in switch that isolates the DC circuit without requiring a separate external disconnect. This makes it safer and faster to shut down the inverter during servicing and shortens installation time, since the electrician doesn't need to purchase and wire a standalone DC disconnect device.
How can the PVI-TL-OUTD inverter be monitored remotely?
The inverter communicates by default via an RS-485 port, while the optional Wi-Fi module adds support for Modbus TCP and SunSpec protocols, enabling integration with both local and remote real-time monitoring systems. This flexibility lets installers connect the inverter to various energy management platforms without needing extra protocol converters.
What type of installation benefits from the PVI-TL-OUTD's wide input voltage range?
The wide input voltage range allows strings with fewer PV modules than typical three-phase inverters require, giving designers more freedom on roofs with limited space or unusual shapes. A shorter string also simplifies wiring and BoS component selection, which meaningfully reduces material costs and installation time.