Rated AC (kW)
0.24
Weak · bottom 2%
Euro eff. (%)
-
Not published
MPPT
1
Weak · bottom 15%
Max DC (V)
60
Typical · median 60 V
Weight (kg)
1.1
Typical · median 3.3 kg
Warranty (yrs)
25
Strong · top 10%
Ranking
Metric
This inverter
Median
Position in class
Rank in class
European efficiency
-
96.0%
Not published
-
MPPT trackers
1
2
Weak · bottom 15%
153
Max DC input voltage
60 V
60 V
Typical
72
Weight per kW
4.5
3.5
Typical
177
Warranty
25 yrs
12 yrs
Strong · top 10%
1
Colour key
Strong - top 25%
Typical - middle 50%
Weak - bottom 25%
Specifications
Rated AC power
0.24 kW
Continuous output
Max AC power
0.25 kW
Short-term output above the rating
Max apparent power
0.25 kVA
Phases
Single-phase
Nominal AC voltage
240 V
211-264V (240V), 183-229V (208V)
Max AC current
1.1 A
Grid frequency
60 Hz
Range 49-68
Power factor
0.85 leading ... 0.85 lagging
Harmonic distortion (THD)
5.0 %
Max DC input power
0.35 kW
DC/AC ratio 1.46
Max DC voltage
60 V
Caps the string length
MPPT voltage range
27 to 45 V
Start-up voltage
22 V
MPPT trackers
1
1 string each
Max input current per MPPT
12.0 A
Must exceed the panel's Imp
Max short-circuit current per MPPT
25.0 A
Must exceed the panel's Isc
Max efficiency
97.6 %
Best single operating point
CEC efficiency
97.0 %
California Energy Commission weighting
Dimensions
212 × 175 × 30 mm
Height × width × depth
Weight
1.1 kg
4.5 kg per kW
Cooling
natural
Operating temperature
-40 to 65 °C
Max humidity
100 %
Warranty
25 years
Standard manufacturer cover
Certifications
CA Rule 21 (UL 1741-SA)UL 62109-1IEEE 1547:2018 (UL 1741-SB 3rd Ed.)HEI Rule 14H SRD 2.0FCC Part 15 Class BICES-0003 Class BCAN/CSA-C22.2 NO. 107.1-01