Deye SUN-23K-G05

23 kW Grid-tie Three-phase
Datasheet PDF
Rated AC (kW)
23.00
Typical for its class
Euro eff. (%)
98.0
Typical · median 98.0%
MPPT
2
Typical · median 2
Max DC (V)
1100
Strong · top 19%
Weight (kg)
20.0
Strong · 18.0 kg below median
Warranty (yrs)
5
Typical · median 5 yrs

The Deye SUN-G05 series consists of three-phase grid-tied inverters built for commercial and industrial installations, where stable operation under high generated power really matters. The series stands out thanks to its dual MPPT trackers, which allow independent optimization of two separate module strings, a real advantage when dealing with uneven shading or panels mounted at different angles on a roof or ground-mount array. Inverters in this line support a zero-export function, letting installers precisely limit power fed back into the grid in line with grid operator requirements or prosumer agreements. A key feature is the built-in VSG (Virtual Synchronous Generator) mode, which improves the inverter's behavior during grid disturbances and strengthens its compliance with modern grid-connection requirements. The design also includes a wide output voltage range, making it easier to operate reliably under unstable local grid conditions, while the optional anti-PID function protects PV modules from potential-induced degradation, extending their service life. Optional per-string monitoring is also available, significantly speeding up fault diagnosis in large-scale installations. The SUN-G05 series is aimed at installers and investors seeking a solution that combines high configuration flexibility with solid service support and compliance with major international grid-connection standards.

Ranking

623 inverters from 12 to 30 kW
Metric This inverter Median Position in class Rank in class
European efficiency 98.0% 98.0% Typical 167
MPPT trackers 2 2 Typical 168
Max DC input voltage 1100 V 1000 V Strong · top 19% 1
Weight per kW 0.9 1.8 Strong · top 6% 36
Warranty 5 yrs 5 yrs Typical 81
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 23 kW Continuous output
Max apparent power 25.30 kVA
Phases Three-phase
Nominal AC voltage 400 V 0.85Un-1.1Un
Max AC current 38.4 A
Grid frequency 50 Hz Range 45-55/55-65
Power factor 0.8 leading to 0.8 lagging
Harmonic distortion (THD) 3.0 %
Max DC input power 29.90 kW DC/AC ratio 1.30
Max DC voltage 1100 V Caps the string length
MPPT voltage range 200 to 1000 V
Start-up voltage 250 V
MPPT trackers 2 1 string each
Max input current per MPPT 26.0 A Must exceed the panel's Imp
Max short-circuit current per MPPT 39.0 A Must exceed the panel's Isc
European efficiency 98.0 % Weighted across part loads
Max efficiency 98.5 % Best single operating point
Dimensions 527 × 362 × 220 mm Height × width × depth
Weight 20.0 kg 0.9 kg per kW
Enclosure IP 65
Cooling forced-air
Noise 50 dB
Operating temperature -25 to 60 °C
Max humidity 100 %
Max altitude 4000 m
Interfaces Wi-FiEthernetBluetoothDisplay
Protocols RS485RS232GPRSWIFIBluetooth4GLAN
Protection DC switchSurge protection
Warranty 5 years Standard manufacturer cover
Certifications IEC 61727IEC 62116CEI 0-21EN 50549NRS 097RD 140UNE 217002OVE-Richtlinie R25G99VDE-AR-N 4105IEC/EN 61000-6-1IEC/EN 61000-6-2IEC/EN 61000-6-3IEC/EN 61000-6-4IEC/EN 62109-1IEC/EN 62109-2

Pros and cons

5 positive · 2 caution
What owners get
Dual MPPT for flexible configuration

Two independent MPP trackers allow optimization of two separate module strings, which matters under uneven shading or mismatched panel orientation - a standard feature in this class but less common in smaller single-phase inverters.

Zero-export compliant with grid operator rules

Built-in zero-export functionality allows precise control of grid feed-in without additional external hardware, simplifying compliance with prosumer contracts and local DSO regulations in commercial installations.

VSG mode for improved grid stability

Virtual Synchronous Generator mode improves inverter behavior during voltage and frequency grid disturbances, increasingly required by grid operators for large PV interconnections - a feature absent in many competing inverters at this price point.

High peak efficiency of ~98.3%

Official manufacturer data lists peak efficiency up to 98.3%, with grid current THD below 3%, in line with typical tier-1 three-phase commercial inverter specifications.

Optional string monitoring and anti-PID

Optional per-string monitoring modules and an anti-PID function speed up fault diagnostics and protect PV modules from potential-induced degradation, extending system lifetime in large commercial installations.

Trade-offs
Lower efficiency than leading HV string units

Peak efficiency of ~98.3% is solid but remains below the 99% offered by leading tier-1 three-phase string inverters (e.g., Huawei SUN2000, Sungrow SG series), which can translate into a measurable difference in annual yield at scale.

No hybrid (energy storage) capability

The SUN-G05 series consists of grid-tie-only inverters with no battery storage support, unlike Deye's hybrid lineup (e.g., SUN-K-SG), limiting its use in projects requiring backup power or energy arbitrage.

Alternatives

All Deye inverters
Inverter Power Euro eff. MPPT Weight Difference
Deye SUN-23K-G05 23 kW 98.0% 2 20.0 kg You are here
SG23T-P2-CN 23 kW 98.3% 2 19.0 kg 1.0 kg lighter
SOFAR 23KTLX-G3P 23 kW 98.1% 2 - Similar on paper
T23-M 23 kW 97.8% 2 20.5 kg Similar on paper
T23-G3 23 kW 97.8% 2 21.0 kg 1.0 kg heavier
SUN-23K-G06P3-EU-AM2 23 kW 97.7% 2 16.0 kg 4.0 kg lighter
S5-GC23K-LV 23 kW 97.3% 3 - -0.7 pp efficiency, +1 MPPT
S6-GC3P23K03-LV-ND 23 kW 97.3% - 32.6 kg -0.7 pp efficiency, 12.6 kg heavier
GW23K-SDT-CN-G40 23 kW - 2 17.0 kg 3.0 kg lighter

About the SUN-G05 series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

How does the Deye SUN-G05 inverter differ from the manufacturer's single-phase units?
The SUN-G05 is a three-phase series designed for commercial and industrial installations with higher generated power, unlike Deye's single-phase models aimed at residential prosumer systems. Thanks to dual MPPT trackers and VSG mode, it handles larger, more complex PV systems and unstable grid conditions better, which is critical for larger-scale installations.
What does the dual MPPT tracker in the SUN-G05 inverter offer and when is it useful?
Two independent MPPT trackers allow simultaneous optimization of two separate module strings, which matters when part of the array is partially shaded or panels are installed at different angles, for example some on a roof and some on the ground. This results in higher total energy yield than a single shared MPPT tracker handling all strings.
Does the Deye SUN-G05 inverter support zero-export, and what is it for?
Yes, the SUN-G05 series has a built-in zero-export function that lets installers limit or completely block surplus energy from being fed back into the grid. This is useful when the grid operator or prosumer agreement imposes export limits, helping investors avoid penalties or extra fees for exceeding permitted thresholds.
What is VSG mode in the SUN-G05 inverter and does it matter when choosing a model?
VSG, or Virtual Synchronous Generator, simulates the behavior of a traditional synchronous generator, improving inverter stability during grid voltage or frequency disturbances. It's worth considering because it increases compliance with modern grid connection requirements and makes it easier to obtain approval for connecting larger installations.
Does the Deye SUN-G05 inverter protect PV modules from PID degradation?
The SUN-G05 series includes an optional anti-PID function that prevents potential-induced degradation in PV modules. This matters in large installations where potential differences between panels and the frame can gradually reduce cell efficiency. Enabling this feature extends panel lifespan and limits long-term power loss.
Can individual strings connected to the SUN-G05 inverter be monitored separately?
Yes, SUN-G05 series inverters offer optional per-string monitoring, allowing quick identification of an underperforming string, for example due to a faulty panel or soiling. In large commercial installations, this significantly reduces fault diagnosis time and lowers service costs compared to inverters without this feature.