Skip to main content

Deye SUN-10K-SG02LP2-US-AM3-P

10 kW Hybrid Single-phase Battery-ready
Datasheet PDF
Rated AC (kW)
10.00
Typical for its class
Euro eff. (%)
96.5
Weak · bottom 10%
MPPT
-
Not published
Max DC (V)
500
Weak · bottom 10%
Weight (kg)
40.0
Weak · 13.0 kg above median
Warranty (yrs)
5
Typical · median 5 yrs

The Deye SUN-SG02LP2 series is a lineup of single-phase hybrid inverters built for the North American split-phase market (120/240V), combining on-grid, off-grid, and energy storage functions in a single unit. The series stands out thanks to its high battery charge and discharge current, enabling fast energy buffering even during sharp power demand spikes in a home or small business. The model supports parallel operation of up to 16 units, allowing easy scaling to higher-capacity installations without replacing existing hardware. A key advantage is the near-instant switching between grid-tied and off-grid operation, taking only a few milliseconds, which effectively eliminates power interruptions to critical loads during grid outages. The series also supports integration with diesel generators, making it an attractive choice where the grid is unstable or blackouts are frequent. The unit delivers high energy conversion efficiency along with low harmonic distortion, resulting in stable operation and reduced losses across the entire PV system. With a compact enclosure and resistance to harsh outdoor conditions, the SUN-SG02LP2 is a solid choice for installers seeking a flexible, outage-resilient hybrid solution for residential homes and small commercial sites in North America.

Ranking

839 inverters from 6 to 12 kW
Metric This inverter Median Position in class Rank in class
European efficiency 96.5% 97.5% Weak · bottom 10% 507
MPPT trackers - 2 Not published -
Max DC input voltage 500 V 800 V Weak · bottom 10% 640
Weight per kW 4.0 3.0 Weak · bottom 22% 633
Warranty 5 yrs 5 yrs Typical 123
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 10 kW Continuous output
Max apparent power 10.00 kVA
Phases Single-phase
Nominal AC voltage 240 V 0.88Un-1.1Un
Max AC current 41.7 A
Grid frequency 60 Hz Range 55-65Hz
Power factor 0.8 leading to 0.8 lagging
Harmonic distortion (THD) 3.0 %
Max DC input power 15.00 kW DC/AC ratio 1.50
Max DC voltage 500 V Caps the string length
MPPT voltage range 150 to 425 V
Start-up voltage 125 V
Max input current per MPPT 32.0 A Must exceed the panel's Imp
Max short-circuit current per MPPT 60.0 A Must exceed the panel's Isc
European efficiency 96.5 % Weighted across part loads
Max efficiency 97.6 % Best single operating point
Battery port Yes
Battery voltage 40-60V
Max charge current 250.0 A
Max discharge current 250.0 A
Dimensions 800 × 450 × 243 mm Height × width × depth
Weight 40.0 kg 4.0 kg per kW
Enclosure TYPE3R
Cooling forced-air
Noise 45 dB
Operating temperature -40 to 60 °C
Max humidity 100 %
Max altitude 2000 m
Interfaces Wi-FiDisplay
Protocols WIFIRS485
Protection AFCIDC switchSurge protection
Warranty 5 years Standard manufacturer cover
Certifications FCCUL 1741IEEE 1547.1SRD V2.0

Pros and cons

5 positive · 2 caution
What owners get
Millisecond grid/off-grid switchover

Switching between on-grid and island mode takes only a few milliseconds, virtually eliminating power interruptions for critical loads during a grid outage - a notable edge over hybrid inverters that typically need 10-20 ms or longer.

High battery charge/discharge current

Per manufacturer documentation, maximum battery charge/discharge current reaches up to 250 A depending on the power variant, enabling fast energy buffering during large load swings in a home or small business.

Scalable up to 16 parallel units

The series supports parallel operation of up to 16 units simultaneously in both on-grid and off-grid modes, allowing easy scaling to larger system sizes without replacing already installed hardware.

High conversion efficiency

Manufacturer datasheets list maximum efficiency up to 97.6% and MPPT efficiency up to 99.9%, translating into lower system-wide energy losses compared to average split-phase hybrid inverters in this segment.

Purpose-built for US split-phase market

The model is specifically engineered for the North American 120/240 V split-phase standard with genset compatibility, making it well suited to regions with unstable grids and frequent blackouts.

Trade-offs
Inconsistent datasheet figures across revisions

Official Deye datasheets for different revisions (AM2 vs AM3-P) list conflicting maximum battery current values (190 A vs 250 A) and ingress protection ratings (IP65 vs Type 3R), requiring installers to verify the exact revision before purchase.

Standard 5-year warranty

Per Deye's general warranty agreement (v2.3), the base inverter warranty is 5 years, with an option to extend to 10 years depending on the country - shorter than some tier-1 competitors that offer a standard 10-year term at no extra cost.

Alternatives

All Deye inverters
Inverter Power Euro eff. MPPT Weight Difference
Deye SUN-10K-SG02LP2-US-AM3-P 10 kW 96.5% - 40.0 kg You are here
SE10000H 10 kW 99.0% - 19.6 kg +2.5 pp efficiency, 20.4 kg lighter
SigenStor Neo EC 10.0 TP 10 kW 98.7% - 30.0 kg +2.2 pp efficiency, 10.0 kg lighter
Sigen Hybrid 10.0 TP2 10 kW 98.5% 2 19.5 kg +2.0 pp efficiency, 20.5 kg lighter
HYX-H10K-HSA2 10 kW 98.2% - 38.0 kg +1.7 pp efficiency, 2.0 kg lighter
HYX-H10K-HT 10 kW 98.2% 2 34.0 kg +1.7 pp efficiency, 6.0 kg lighter
MOD 10KTL3-XH 10 kW 98.1% 2 14.0 kg +1.6 pp efficiency, 26.0 kg lighter
MOD 10KTL3-HU 10 kW 98.1% 3 20.0 kg +1.6 pp efficiency, 20.0 kg lighter
SUN2000-10KTL-M1 10 kW 98.1% 2 17.0 kg +1.6 pp efficiency, 23.0 kg lighter

About the SUN-SG02LP2 series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

How many SUN-SG02LP2 units can be connected in parallel?
The SUN-SG02LP2 series supports parallel operation of up to 16 units, allowing the system to scale from a single-family home to larger commercial installations without replacing existing equipment. Installers can simply add more inverters to the existing split-phase 120/240V setup. This makes the series well suited for phased projects where system capacity grows over time as the customer's needs increase.
What is the maximum battery charge and discharge current on the SUN-SG02LP2?
Depending on the specific power variant (5-12 kW), the maximum battery charge and discharge current reaches up to 250 A, a high figure compared to competing hybrid inverters in this segment. This allows the unit to quickly buffer energy during sudden load spikes, such as an AC unit or heat pump starting up. Battery voltage range is 40-60V, matching common lithium-ion storage systems.
How fast does the SUN-SG02LP2 switch between grid and off-grid mode during an outage?
The transfer takes only a few milliseconds, which is effectively undetectable for most household loads, including electronics and appliances. This keeps critical circuits such as refrigerators, routers, and lighting running without interruption even during unstable grid conditions or blackouts. This millisecond-level transfer time is one of the series' key advantages over grid-tied inverters without backup capability.
Does the SUN-SG02LP2 support connection to a generator?
Yes, the SUN-SG02LP2 series supports connecting a generator as a backup power source, which is valuable in areas with frequent or extended grid outages. The inverter automatically manages power source priority (PV, battery, generator, grid), optimizing fuel use and extending system runtime in emergency mode. This feature is especially appreciated in projects located in regions with unstable grid infrastructure.
What is the conversion efficiency of the SUN-SG02LP2, and does it introduce grid disturbances?
Maximum conversion efficiency reaches 97.6%, with THDi (harmonic distortion) kept below 3% of rated power. This translates into lower energy losses across the whole PV system and compliance with grid-interconnection requirements such as IEEE 1547 and UL 1741. For end users, this means a more stable installation and lower risk of power-quality issues on the grid side.
Is the SUN-SG02LP2 suitable for outdoor installation in harsh weather conditions?
Yes, the compact, reinforced enclosure is designed to handle variable outdoor conditions, allowing mounting either indoors or outdoors. This design reduces siting constraints for installers and makes the unit practical across the diverse climates found in the North American market, from colder northern states to more humid southern regions.