Skip to main content

Bluesun BMPS50

50 kW Hybrid Three-phase Battery-ready
Datasheet PDF
Rated AC (kW)
50.00
Typical for its class
Euro eff. (%)
-
Not published
MPPT
-
Not published
Max DC (V)
1000
Typical · median 1100 V
Weight (kg)
720.0
Weak · 645.0 kg above median
Warranty (yrs)
-
Not published

Ranking

676 inverters from 30 to 100 kW
Metric This inverter Median Position in class Rank in class
European efficiency - 98.2% Not published -
MPPT trackers - 4 Not published -
Max DC input voltage 1000 V 1100 V Typical 375
Weight per kW 14.4 1.2 Weak · bottom 1% 640
Warranty - 5 yrs Not published -
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 50 kW Continuous output
Max apparent power 55.00 kVA
Phases Three-phase
Nominal AC voltage 400 V 320V-460V
Max AC current 72.0 A
Grid frequency 50 Hz Range 45-55/55-65Hz
Power factor 1 lagging - 1 leading
Harmonic distortion (THD) 3.0 %
Max DC voltage 1000 V Caps the string length
MPPT voltage range 250 to 850 V
Battery port Yes
Battery voltage 250V-850V (BMPS30) to 500V-850V (BMPS500), varies by model
Grid-forming Yes
Dimensions 1900 × 800 × 800 mm Height × width × depth
Weight 720.0 kg 14.4 kg per kW
Enclosure IP20
Cooling forced-air
Noise 70 dB
Operating temperature -25 to 55 °C
Max humidity 95 %
Max altitude 5000 m
Interfaces Display
Protocols RS485CAN

Alternatives

All Bluesun inverters
Inverter Power Euro eff. MPPT Weight Difference
Bluesun BMPS50 50 kW - - 720.0 kg You are here
50M1-HYB 50 kW 98.3% - 102.0 kg 618.0 kg lighter
50M1-HYA 50 kW 98.3% - 72.0 kg 648.0 kg lighter
AF50K-TH 50 kW 98.3% 4 70.0 kg 650.0 kg lighter
H3-50-Plus 50 kW 98.1% - 115.0 kg 605.0 kg lighter
P3-50-Plus 50 kW 98.1% - 115.0 kg 605.0 kg lighter
HP3-50KS1 50 kW 98.0% 5 80.0 kg 640.0 kg lighter
HYX-H50K-ET 50 kW 98.0% - 95.0 kg 625.0 kg lighter
GW50K-ET-10 50 kW 97.8% - 65.0 kg 655.0 kg lighter