Skip to main content

ATESS HPS50000TL

50 kW Hybrid Three-phase Battery-ready
Datasheet PDF
Rated AC (kW)
50.00
Typical for its class
Euro eff. (%)
-
Not published
MPPT
3
Weak · bottom 17%
Max DC (V)
1000
Typical · median 1100 V
Weight (kg)
90.0
Weak · 15.0 kg above median
Warranty (yrs)
-
Not published

The ATESS HPS TL series consists of three-phase, all-in-one hybrid inverters built for small and medium commercial installations where power reliability and configuration flexibility matter most. These units feature a built-in ATS (automatic transfer switch), allowing a site to shift seamlessly between the utility grid, a diesel generator, and off-grid operation without interrupting the power supply. A key advantage is the seamless on/off-grid transfer in under 10 ms, protecting critical loads from the effects of voltage interruptions - essential for retail stores, workshops, farms, or small production facilities. The inverters come in a sealed IP65-rated enclosure, enabling outdoor installation without extra protective infrastructure and reducing installation costs. Thanks to parallel operation of up to 10 units, the HPS TL series scales alongside a growing installation - from tens of kilowatts up to capacities approaching large commercial systems - without requiring equipment replacement. Multiple MPPT inputs give installers the flexibility to design PV arrays with varied orientation and shading conditions, while remote generator control and programmable working modes simplify integration with a site's existing power infrastructure. This is a solution for installers seeking a compact, weatherproof hybrid device for commercial applications that demand uninterrupted power continuity.

Ranking

552 inverters from 30 to 100 kW
Metric This inverter Median Position in class Rank in class
European efficiency - 98.2% Not published -
MPPT trackers 3 4 Weak · bottom 17% 214
Max DC input voltage 1000 V 1100 V Typical 298
Weight per kW 1.8 1.2 Weak · bottom 16% 434
Warranty - 5 yrs Not published -
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 50 kW Continuous output
Max apparent power 55.00 kVA
Phases Three-phase
Nominal AC voltage 400 V 360V-440V
Max AC current 72.0 A
Grid frequency 50 Hz Range 45~55/55~65Hz
Power factor 0.8 lagging~0.8 leading
Harmonic distortion (THD) 3.0 %
Max DC input power 100.00 kW DC/AC ratio 2.00
Max DC voltage 1000 V Caps the string length
MPPT voltage range 125 to 850 V
MPPT trackers 3 3 strings each
Max input current per MPPT 20.0 A Must exceed the panel's Imp
Max short-circuit current per MPPT 20.0 A Must exceed the panel's Isc
Battery port Yes
Battery voltage 150-800V
Max charge current 100.0 A
Max discharge current 100.0 A
Backup power 50.00 kW Output during a grid outage
Grid-forming Yes
Dimensions 990 × 600 × 280 mm Height × width × depth
Weight 90.0 kg 1.8 kg per kW
Enclosure IP65
Cooling forced-air
Noise 65 dB
Operating temperature -40 to 60 °C
Max humidity 100 %
Max altitude 5000 m
Interfaces Display
Protocols RS485CAN
Protection AFCIDC switchSurge protection
Certifications CEEN IEC 61000-6-4:2019EN 61000-3-12:2011EN IEC 61000-3-11:2019EN IEC 61000-6-2:2019EN62109-1:2010EN62109-2:2011NRS097-2-1:2017AS4777.2

Pros and cons

5 positive · 2 caution
What owners get
Seamless switching under 10 ms

The built-in ATS enables transfer between grid, generator and off-grid operation in under 10 ms, faster than the typical 20-50 ms seen in competing commercial hybrids without a dedicated ATS. This protects critical loads (cold storage, servers, production lines) from power interruptions.

IP65 enclosure for outdoor mounting

The IP65 protection rating allows direct outdoor installation without a dedicated switchgear room or canopy, reducing civil works costs compared to IP20/IP21 units that require indoor placement.

Scalable up to 10 parallel units

Parallel operation of up to 10 HPS TL units allows scaling from roughly 15-50 kW per unit to several hundred kW without replacing hardware, extending the investment's lifespan as a commercial facility grows.

Multi-input MPPT for flexible PV design

Available variants (e.g. HPS30000TL with 2 MPPTs, 125-850 VDC range) allow splitting the PV array across strings with different orientation and shading, improving actual yield on irregular commercial rooftops.

Compliance with international standards

Product documentation lists CE, EN62109 and AS4777.2 compliance, easing deployment of the series in European and Australian markets without additional local certification.

Trade-offs
Inconsistent parallel-unit limits across HPS family

While the TL series claims up to 10 parallel units, larger HPS models (30/50/100/120/150) in ATESS documentation state an 8-unit limit - this inconsistency in vendor materials can mislead installers designing larger multi-unit arrays.

No publicly available, independent pricing

ATESS does not publish pricing for the HPS TL series, and regional distributors only show stock availability without rates - this makes it harder to benchmark cost per kWp against tier-1 competitors (e.g. Deye, Sungrow) without a direct quote request.

Alternatives

All ATESS inverters
Inverter Power Euro eff. MPPT Weight Difference
ATESS HPS50000TL 50 kW - 3 90.0 kg You are here
50M1-HYB 50 kW 98.3% - 102.0 kg 12.0 kg heavier
50M1-HYA 50 kW 98.3% - 72.0 kg 18.0 kg lighter
AF50K-TH 50 kW 98.3% 4 70.0 kg +1 MPPT, 20.0 kg lighter
H3-50-Plus 50 kW 98.1% - 115.0 kg 25.0 kg heavier
P3-50-Plus 50 kW 98.1% - 115.0 kg 25.0 kg heavier
HP3-50KS1 50 kW 98.0% 5 80.0 kg +2 MPPT, 10.0 kg lighter
HYX-H50K-ET 50 kW 98.0% - 95.0 kg 5.0 kg heavier
GW50K-ET-10 50 kW 97.8% - 65.0 kg 25.0 kg lighter

About the HPS TL series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

Will the ATESS HPS TL inverter keep a shop or workshop powered during a grid outage?
Yes, this is one of the series' core functions. The built-in ATS switches power between the grid, a generator, and off-grid operation in under 10 ms, which is unnoticeable to most equipment. This means cash registers, refrigeration units, or workshop machinery won't shut down during a brief voltage drop, which matters for small and mid-sized businesses that depend on uninterrupted power.
How does the built-in ATS in the HPS TL differ from an external grid transfer switch?
An external ATS requires extra wiring, additional installation work, and typically introduces a noticeable power interruption of tens to hundreds of milliseconds. In the HPS TL, the ATS is integrated into the inverter and switches power in under 10 ms, with no interruption noticeable to electronic equipment. This simplifies installation, lowers material costs, and removes one more component that could desync or fail.
How many ATESS HPS TL units can be paralleled, and how large can the system scale?
The HPS TL series supports parallel operation of up to 10 units, scaling system power from tens of kilowatts up to levels typical of larger commercial systems. In practice, a business can start with a single inverter and add more units as energy demand grows, without replacing the equipment already installed, protecting the initial investment.
Can the HPS TL inverter be installed outdoors without a canopy or shelter?
Yes, the HPS TL enclosure has an IP65 rating, meaning it is dust-tight and protected against water jets, allowing outdoor installation without any additional sheltering infrastructure. This means installers don't need to build a canopy or technical cabinet, which shortens installation time and reduces costs, especially on farms and small production facilities where indoor space is limited.
How many MPPT inputs does the ATESS HPS TL series have, and how does that affect PV array design?
The HPS TL is equipped with a multi-input MPPT system, allowing several independent PV strings with different orientations, tilt angles, or shading conditions to connect to a single inverter. For installers, this means greater freedom in laying out panels on a roof or across multiple roofs at once, without losing energy yield to averaged operating parameters across the whole PV array.
Can the ATESS HPS TL be integrated with a backup generator on site?
Yes, the inverter supports remote generator control and programmable operating modes, enabling automatic generator start-up when needed and smooth switching between the grid, the generator, and battery storage or off-grid operation. This simplifies integration with a facility's existing backup power infrastructure, removing the need for staff to manually operate transfer switches.