Skip to main content
ATESS HPS50

ATESS HPS50

50 kW Hybrid Three-phase Battery-ready
Datasheet PDF
Rated AC (kW)
50.00
Typical for its class
Euro eff. (%)
-
Not published
MPPT
-
Not published
Max DC (V)
1000
Typical · median 1100 V
Weight (kg)
610.0
Weak · 535.0 kg above median
Warranty (yrs)
-
Not published

The ATESS HPS series consists of all-in-one hybrid inverters built for commercial and industrial installations, where uninterrupted power delivery matters just as much as conversion efficiency. Each unit integrates the inverter, transformer, and transfer switching gear into a single enclosure, removing the need for extra BoS components and simplifying on-site installation. The series' standout feature is its seamless switching between grid-tied and off-grid operation in under 10 ms, making it a strong fit for facilities that cannot tolerate power interruptions, such as data centers, manufacturing plants, or logistics hubs. HPS units also support parallel operation of up to 8 devices, allowing a single installation to scale up to 1200 kW of capacity without redesigning the system architecture. The inverters offer programmable working modes and remote control of a diesel generator (DG), enabling flexible management of hybrid energy sources, PV, battery, grid, and generator, based on tariffs and load demand. An intuitive touchscreen LCD simplifies configuration and monitoring without external tools. It's a solution built for integrators and investors seeking a reliable, scalable alternative to conventional UPS systems and grid-tied inverters.

Ranking

552 inverters from 30 to 100 kW
Metric This inverter Median Position in class Rank in class
European efficiency - 98.2% Not published -
MPPT trackers - 4 Not published -
Max DC input voltage 1000 V 1100 V Typical 298
Weight per kW 12.2 1.2 Weak · bottom 1% 516
Warranty - 5 yrs Not published -
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 50 kW Continuous output
Max apparent power 55.00 kVA
Phases Three-phase
Nominal AC voltage 400 V 360V-440V
Max AC current 72.0 A
Grid frequency 50 Hz Range 45~55/55~65Hz
Power factor 0.8 lagging~0.8 leading
Harmonic distortion (THD) 3.0 %
Max DC input power 75.00 kW DC/AC ratio 1.50
Max DC voltage 1000 V Caps the string length
MPPT voltage range 480 to 800 V
Battery port Yes
Battery voltage 352V-600V
Grid-forming Yes
Dimensions 1860 × 950 × 750 mm Height × width × depth
Weight 610.0 kg 12.2 kg per kW
Enclosure IP20
Cooling forced-air
Noise 75 dB
Operating temperature -25 to 55 °C
Max humidity 95 %
Max altitude 6000 m
Interfaces Display
Protocols RS485CAN
Protection Surge protection
Certifications CEMEAPEAUKCAAS 4777.2EN 61000-6-2:2019EN 61000-6-4:2019EN62109-1:2010EN62109-2:2011EN 50549-1:2019IEC62109.1IEC62109.2NRS 097-2-1:2017G99VDE-AR-N 4105:2018DIN VDE V 0124-100:2020-06PSE:2018-12DEWA

Pros and cons

5 positive · 2 caution
What owners get
Grid/off-grid switchover <10 ms

Transfer time below 10 ms between on-grid and off-grid operation practically eliminates power interruptions for critical loads, putting the HPS series in the same league as dedicated UPS systems rather than typical hybrid inverters.

Parallel operation up to 8 units / 1200 kW

Per ATESS's current datasheets (HPS100/120/150 models), the system scales to 8 inverters in parallel with up to 1200 kW total capacity, allowing installations to grow without changing the system architecture - older 2024 documentation still cited only 4 units and 600 kW.

All-in-one: inverter + transformer + ATS

Integrating the transformer and automatic transfer switch (ATS) into a single enclosure removes the need for external BoS components, cutting on-site installation time and reducing the number of service interfaces.

Remote hybrid PV-battery-generator management

Programmable operating modes and remote generator control enable automatic energy cost optimization based on tariffs and load - a feature rarely available in commercial inverters of this power class.

Touchscreen LCD for on-site configuration

A built-in touchscreen allows full configuration and monitoring without a laptop or extra software, shortening commissioning time for integrators.

Trade-offs
Inconsistent parallel-unit specs across documentation

ATESS's official materials are not fully consistent over time: 2024 documents cite 4 units/600 kW, a 2025 white paper mentions only 2 units, while the latest datasheets state 8 units/1200 kW. Buyers should confirm the current limit for the specific model before designing an installation.

Manufacturer lacks long market track record

ATESS was founded in 2017, giving it a shorter operating history than Tier-1 inverter makers (Huawei, SMA, Sungrow, with 15-20+ years in business), meaning less field data on long-term hardware durability.

Alternatives

All ATESS inverters
Inverter Power Euro eff. MPPT Weight Difference
ATESS HPS50 50 kW - - 610.0 kg You are here
50M1-HYB 50 kW 98.3% - 102.0 kg 508.0 kg lighter
50M1-HYA 50 kW 98.3% - 72.0 kg 538.0 kg lighter
AF50K-TH 50 kW 98.3% 4 70.0 kg 540.0 kg lighter
H3-50-Plus 50 kW 98.1% - 115.0 kg 495.0 kg lighter
P3-50-Plus 50 kW 98.1% - 115.0 kg 495.0 kg lighter
HP3-50KS1 50 kW 98.0% 5 80.0 kg 530.0 kg lighter
HYX-H50K-ET 50 kW 98.0% - 95.0 kg 515.0 kg lighter
GW50K-ET-10 50 kW 97.8% - 65.0 kg 545.0 kg lighter

About the HPS series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

How does grid/island switching in the ATESS HPS differ from a standard UPS?
HPS series units perform automatic transfer between grid-tied and off-grid operation in under 10 ms, matching the performance level of a classic online UPS. In practice, critical loads such as servers or production lines do not experience a power interruption during a grid outage. Unlike a typical UPS, the HPS also integrates a transformer and hybrid energy management for PV, battery, and generator sources in a single enclosure.
How many ATESS HPS units can be paralleled and what power output can be reached?
The HPS series supports parallel operation of up to 8 units, allowing a single installation to scale up to 1200 kW without changing the system architecture. It is worth confirming the current documentation and firmware for a specific model with the distributor, since earlier versions of the series allowed fewer parallel units and a lower maximum output.
Can the ATESS HPS inverter remotely control a diesel generator?
Yes, the HPS supports remote generator control, automatically starting and stopping the genset based on battery state, load, or grid availability. This lets a hybrid installation flexibly switch between PV, battery, grid, and generator, minimizing fuel consumption and generator runtime, which is valuable for industrial sites without constant technical supervision.
What type of facilities is the ATESS HPS series best suited for?
The HPS is designed for commercial and industrial installations where uninterrupted power to critical loads is the priority - data centers, manufacturing plants, logistics hubs, and retail facilities. Integrating the inverter, transformer, and transfer switch in one enclosure reduces the number of additional BoS components and simplifies on-site installation, making the series a strong alternative to classic grid-tied inverters and UPS systems.
Does configuring and monitoring the HPS inverter require extra software?
No, HPS units feature a built-in touchscreen LCD that allows full configuration of operating modes and monitoring of key parameters directly on the device, with no need for external software or a service laptop. Programmable operating modes are also available, letting users plan battery charge and discharge priorities based on electricity tariffs and the site's load profile.
What is the warranty on ATESS HPS inverters and where can I check the details?
ATESS, a China-based manufacturer, provides a standard factory warranty on the HPS series, though the exact duration and coverage (including any extended warranty options) vary by model and target market. Before purchasing, it is recommended to ask the distributor for the current warranty card for the specific model, since terms may exclude damage caused by unauthorized changes to the inverter's operating parameters.