Skip to main content
ATESS HPS15000TL

ATESS HPS15000TL

15 kW Hybrid Three-phase Battery-ready
Datasheet PDF
Rated AC (kW)
15.00
Weak · bottom 17%
Euro eff. (%)
-
Not published
MPPT
2
Typical · median 2
Max DC (V)
1000
Typical · median 1000 V
Weight (kg)
45.0
Weak · 7.0 kg above median
Warranty (yrs)
-
Not published

The ATESS HPS-TL series comprises three-phase hybrid inverters in the 15-30 kW range, built for small and mid-sized commercial installations where both power reliability and configuration flexibility matter. These units stand out thanks to hybrid on/off-grid operation with seamless switching, keeping the facility powered regardless of the public grid status, while a built-in automatic transfer switch (ATS) removes the need for additional switching hardware. With parallel operation of up to 10 units, the HPS-TL series lets system capacity scale flexibly as a site grows, without having to replace the inverter with a larger model. A rugged, IP65-rated weatherproof enclosure combined with a wide operating temperature range allows outdoor mounting, lowering balance of system (BoS) costs and simplifying installation design. The transformerless topology with multiple MPPT inputs improves energy efficiency and makes it easier to match different PV string and battery storage configurations. The inverter also offers programmable working modes and remote control of a diesel generator, making it a solid choice for businesses, farms, schools, or small production facilities that need continuity of supply and energy autonomy.

Ranking

623 inverters from 12 to 30 kW
Metric This inverter Median Position in class Rank in class
European efficiency - 98.0% Not published -
MPPT trackers 2 2 Typical 168
Max DC input voltage 1000 V 1000 V Typical 229
Weight per kW 3.0 1.8 Weak · bottom 18% 491
Warranty - 5 yrs Not published -
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 15 kW Continuous output
Max apparent power 16.00 kVA
Phases Three-phase
Nominal AC voltage 400 V 360V-440V
Max AC current 21.0 A
Grid frequency 50 Hz Range 45~55/55~65Hz
Power factor 0.8 lagging~0.8 leading
Harmonic distortion (THD) 3.0 %
Max DC input power 23.00 kW DC/AC ratio 1.53
Max DC voltage 1000 V Caps the string length
MPPT voltage range 125 to 850 V
MPPT trackers 2 2 strings each
Max input current per MPPT 40.0 A Must exceed the panel's Imp
Max short-circuit current per MPPT 20.0 A Must exceed the panel's Isc
Battery port Yes
Battery voltage 150-700V
Dimensions 635 × 450 × 225 mm Height × width × depth
Weight 45.0 kg 3.0 kg per kW
Enclosure IP65
Cooling forced-air
Noise 65 dB
Operating temperature -40 to 60 °C
Max humidity 100 %
Max altitude 5000 m
Interfaces Display
Protocols RS485CAN
Protection DC switchSurge protection
Certifications CEEN IEC 61000-6-4:2019EN 61000-3-12:2011EN IEC 61000-3-11:2019EN IEC 61000-6-2:2019EN62109-1:2010EN62109-2:2011NRS097-2-1:2017AS4777.2

Pros and cons

4 positive · 3 caution
What owners get
Seamless on/off-grid switching

The HPS-TL series automatically switches power between the public grid, energy storage, and a generator without interruption, a feature not universally standard among commercial hybrid inverters in the 15-30 kW class. This removes the need for a separate UPS in facilities requiring power continuity (schools, production plants).

Scalability up to 10 units in parallel

Parallel operation of up to 10 units allows the system to scale to roughly 300 kW without replacing the inverter with a larger model, lowering upgrade costs as a site's power demand grows. This exceeds the typical 6-8 unit limit found in competing series of this class.

IP65 enclosure for outdoor installation

The IP65 protection rating allows outdoor mounting without an additional canopy or enclosure, meaningfully reducing Balance of System (BoS) costs compared to IP54-rated models that require indoor installation.

Transformerless design with multiple MPPTs

The transformerless topology delivers higher conversion efficiency and lower unit weight than transformer-based solutions of comparable power, while programmable operating modes and remote generator control simplify integration into PV + storage + generator hybrid systems.

Trade-offs
ATS is a separate module, not fully built-in

Manufacturer documentation (the ATESS ATS User Manual) describes the automatic transfer switch as a standalone module paired with the HPS inverter rather than a component fully integrated into the inverter enclosure. In practice, installers must budget for an additional component and its installation, despite marketing materials implying full integration.

Only 2 MPPT inputs on the 15/20 kW variants

Product datasheets for the HPS15000TL and HPS20000TL list just 2 MPPT trackers, limiting flexibility for PV strings with differing orientation or shading compared to competing series in this power class that offer 3-4 MPPT inputs.

Limited independent testing and market track record

Founded in 2017, ATESS is a mid-size (tier-2) manufacturer compared to players like Sungrow, Growatt, or Deye, resulting in fewer independent field tests, public bankability rankings (e.g., BNEF Tier 1 listing), and a smaller European reference installation base for this specific series.

Alternatives

All ATESS inverters
Inverter Power Euro eff. MPPT Weight Difference
ATESS HPS15000TL 15 kW - 2 45.0 kg You are here
SigenStor Neo EC 15.0 TP 15 kW 98.7% - 30.0 kg 15.0 kg lighter
MID 15KTL3-XH 15 kW 98.5% - 31.0 kg 14.0 kg lighter
HYX-H15K-HT 15 kW 98.2% 2 45.0 kg Similar on paper
HYX-H15K-HSA2 15 kW 98.2% - 38.0 kg 7.0 kg lighter
MOD 15KTL3-HU 15 kW 98.1% 3 20.0 kg +1 MPPT, 25.0 kg lighter
SUN2000-15K-MB0 15 kW 98.0% 2 21.0 kg 24.0 kg lighter
HIT-15L-G3/HIT-15L-G3S 15 kW 98.0% - 41.0 kg 4.0 kg lighter
AF15K-THA 15 kW 98.0% 2 36.0 kg 9.0 kg lighter

About the HPS-TL series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

How fast does the ATESS HPS-TL inverter switch power in the event of a grid outage?
The HPS-TL series features a built-in automatic transfer switch (ATS) that detects a grid outage and switches the site to off-grid operation with virtually no interruption. This means critical loads such as cold storage, servers, or production lines do not require a separate UPS. The function also removes the need for an external transfer switch panel, reducing installation time and material costs.
How many ATESS HPS-TL inverters can be connected in parallel in a single installation?
The HPS-TL series supports parallel operation of up to 10 units, allowing total output of several hundred kilowatts without replacing a single unit with a larger model. This is useful as a business or farm's power needs grow in stages. The inverters automatically synchronize operation, so adding another unit does not require complex reconfiguration of the whole system.
Can the ATESS HPS-TL inverter be installed outdoors?
Yes, HPS-TL units have an IP65-rated enclosure, meaning full protection against dust and high-pressure water jets from any direction. Combined with a wide operating temperature range, this allows the inverter to be mounted outdoors, for example on the wall of a utility building or a support structure, without an additional shelter, which lowers balance-of-system (BoS) costs.
How does the transformerless design of the HPS-TL inverter differ from transformer-based inverters?
A transformerless design eliminates the heavy isolation transformer, resulting in higher conversion efficiency, lower weight, and reduced heat losses. The HPS-TL inverter also includes multiple MPPT inputs, enabling independent maximum power point tracking for different PV strings, for example with varying tilt or shading, which increases overall energy yield from the array.
Does the ATESS HPS-TL inverter work with a diesel generator?
Yes, the HPS-TL series supports remote startup and management of a generator as a backup power source during extended grid outages or low energy storage levels. Programmable operating modes let you define power source priorities, which is particularly useful for businesses, farms, and schools that need full energy autonomy with minimal fuel use.
What type of sites is the 15-30 kW ATESS HPS-TL inverter best suited for?
The HPS-TL series is designed for small and medium-sized commercial installations such as manufacturing facilities, farms, schools, and service buildings, where both power continuity and scalable capacity matter. The 15-30 kW per-unit range, combined with parallel operation of up to 10 units, allows precise system sizing to match a site's current needs without oversizing the installation.