Skip to main content
Afore BNT090KTL

Afore BNT090KTL

90 kW Grid-tie Three-phase
Datasheet PDF
Rated AC (kW)
90.00
Strong · top 18%
Euro eff. (%)
98.3
Typical · median 98.2%
MPPT
6
Typical · median 4
Max DC (V)
1100
Typical · median 1100 V
Weight (kg)
78.0
Strong · top 21%
Warranty (yrs)
-
Not published

The Afore BNT series is a lineup of three-phase string inverters built for commercial and industrial installations where configuration flexibility and reliable operation under demanding conditions matter most. A standout advantage of this line is its high DC/AC oversizing ratio, which lets installers connect more panels than conventional designs allow, maximizing energy yield relative to the inverter's rated power and lowering the installation cost per watt. The BNT series addresses a common challenge in commercial projects, namely uneven shading and mixed roof orientations, through multiple independent MPPT trackers with a wide operating voltage range, allowing strings of different lengths and exposures to be combined without sacrificing performance. Installation safety is reinforced by built-in surge protection along with an optional arc fault circuit interrupter (AFCI), a feature particularly valuable in industrial sites with longer DC cabling runs. The inverters feature an anodized aluminum enclosure resistant to corrosion, extending service life in outdoor deployments. A Wi-Fi monitoring module further enables remote oversight of system performance. Spanning models from a few kilowatts up to more than one hundred kilowatts, the BNT series targets system integrators handling commercial rooftops and solar farms who need a scalable, modular solution.

Ranking

552 inverters from 30 to 100 kW
Metric This inverter Median Position in class Rank in class
European efficiency 98.3% 98.2% Typical 85
MPPT trackers 6 4 Typical 55
Max DC input voltage 1100 V 1100 V Typical 12
Weight per kW 0.9 1.2 Strong · top 21% 107
Warranty - 5 yrs Not published -
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 90 kW Continuous output
Max apparent power 90.00 kVA
Phases Three-phase
Nominal AC voltage 400 V 260Vac-519Vac
Max AC current 143.0 A
Grid frequency 50 Hz Range 45-55Hz/55-66Hz
Power factor 0.8 leading to 0.8 lagging
Harmonic distortion (THD) 3.0 %
Max DC input power 135.00 kW DC/AC ratio 1.50
Max DC voltage 1100 V Caps the string length
MPPT voltage range 200 to 1000 V
Start-up voltage 300 V
MPPT trackers 6 2 strings each
Max input current per MPPT 38.0 A Must exceed the panel's Imp
Max short-circuit current per MPPT 48.0 A Must exceed the panel's Isc
European efficiency 98.3 % Weighted across part loads
Max efficiency 99.0 % Best single operating point
Dimensions 610 × 983 × 318 mm Height × width × depth
Weight 78.0 kg 0.9 kg per kW
Enclosure IP66
Cooling forced-air
Operating temperature -25 to 60 °C
Max humidity 100 %
Max altitude 4000 m
Interfaces Wi-FiEthernetDisplay
Protocols RS485WiFiWire EthernetGPRS
Protection AFCIDC switchSurge protection
Certifications EN/IEC 61000-6-2EN/IEC 61000-6-4EN61000-3-11EN61000-3-12IEC 60068UL1741EN62109IEEE1547CSA C22EN50549VDE4105VDE0126RD1699ABNT NBR16149 & 16150AS4777.2NB/T32004G99IEC61727

Pros and cons

5 positive · 3 caution
What owners get
High DC/AC oversizing ratio

BNT series technical documentation supports PV oversizing up to 1.5x relative to the inverter's rated AC power, allowing more panels to be connected and maximizing energy yield without increasing the unit's rated capacity, lowering installation cost per watt.

Multiple independent MPPTs with wide voltage range

BNT series models (e.g., BNT025KTL, BNT036KTL, BNT050KTL) feature 2-3 independent MPPT trackers with an operating voltage range of roughly 200-1000V, enabling strings of varying length and orientation to be combined without performance loss - key for commercial projects with uneven shading.

Built-in Type II surge protection (SPD)

BNT inverters include a built-in Type II SPD and Smart IV Curve Scanning diagnostics, improving safety in industrial installations with longer DC wiring runs and easing fault detection at the individual string level.

Durable anodized aluminum enclosure

The corrosion-resistant anodized aluminum enclosure extends service life for outdoor and industrial installations, reducing the risk of component degradation under harsh weather conditions.

Remote monitoring via WiFi module

A built-in WiFi module (expandable to Ethernet/GPRS per manufacturer documentation) enables remote oversight of plant operation - a useful feature for integrators managing multiple commercial sites.

Trade-offs
Production discontinued in 2022

The BNT series was discontinued in 2022, meaning spare parts availability and warranty service support are limited over the long operational horizon typical of commercial installations (20-25 years).

AFCI offered as optional, not standard

Arc-fault detection (AFCI) is described in available documentation as an optional feature rather than a standard inclusion - unlike many Tier-1 competitor series (e.g., Huawei, SMA) where AFCI is built in by default on commercial models.

Inconsistent power range documentation

Manufacturer and distributor materials cite conflicting power ranges for the series (from 3kW to over 100kW across different sources), making it harder to clearly assess product positioning and potentially misleading buyers during model selection.

Alternatives

All Afore inverters
Inverter Power Euro eff. MPPT Weight Difference
Afore BNT090KTL 90 kW 98.3% 6 78.0 kg You are here
SUN-90K-G03 90 kW 98.3% - 81.0 kg 3.0 kg heavier
SUNSYNK-90K-G03 90 kW 98.1% - 81.0 kg 3.0 kg heavier
SE90K (400V grid) 90 kW 98.0% - - Similar on paper
SE90K (Synergy, 380/400V) 90 kW 98.0% - 32.0 kg 46.0 kg lighter
SE90K (IL00IBNQ4) 90 kW 98.0% - - Similar on paper
92.0 TL3 92 kW 98.6% 1 78.2 kg +2.0 kW, -5 MPPT
87.0 TL3 87 kW 98.6% 1 78.2 kg -3.0 kW, -5 MPPT
PVI 85KW 85 kW - - - -5.0 kW

About the BNT series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

What is the power range of Afore BNT inverters and what installations are they suited for?
The BNT series covers models from around 3 kW up to over 100 kW, making it suitable for a wide range of projects. Smaller units (up to 25 kW) are typically used in small commercial and service buildings, while models above 50-100 kW are deployed in solar farms and large industrial installations that require several independent MPPT trackers.
What does the high DC/AC oversizing ratio in BNT inverters mean, and what are the benefits?
A high DC/AC oversizing ratio means more PV panels can be connected than the inverter's rated AC output. This allows installers to maximize energy yield from the same inverter capacity, lowering the overall installation cost per watt. This is particularly valuable in commercial projects where a fast return on investment is a priority.
How many MPPT trackers does the Afore BNT inverter have, and can it handle strings of different lengths?
Depending on the model, BNT inverters feature two to three independent MPPT trackers, each with a wide operating voltage range (up to 1100 V DC). This allows strings with different panel counts, orientations, or shading levels to be combined without losing performance - a common challenge on irregular commercial roofs.
Does the Afore BNT inverter have arc-fault circuit interruption (AFCI) protection?
Yes, the BNT series offers optional AFCI protection that automatically detects and shuts down the inverter if a dangerous arc fault occurs within the DC wiring. It also includes built-in surge protection, which is important for the longer DC cable runs typical of industrial-scale installations.
Is the Afore BNT inverter series still available for purchase?
The Afore BNT series has been discontinued and is no longer manufactured as a current product line. Availability is now limited to remaining distributor stock. Anyone planning a new installation or system expansion should check current inventory with their supplier or consider newer Afore models with comparable specifications.
Can the Afore BNT inverter enclosure withstand outdoor mounting in harsh weather conditions?
Yes, BNT inverters feature an anodized aluminum enclosure that resists corrosion, making outdoor mounting possible even in humid or salt-exposed environments. This construction extends the unit's service life compared to painted steel enclosures, which is especially valuable for industrial installations operated for years with minimal maintenance oversight.