Skip to main content
Afore AF3K-THA

Afore AF3K-THA

3 kW Hybrid Three-phase Battery-ready
Datasheet PDF
Rated AC (kW)
3.00
Strong · top 21%
Euro eff. (%)
97.5
Strong · top 12%
MPPT
2
Strong · top 22%
Max DC (V)
1000
Strong · top 7%
Weight (kg)
29.0
Weak · 18.2 kg above median
Warranty (yrs)
-
Not published

The Afore AF-TH series comprises three-phase hybrid inverters ranging from 36 to 50 kW, built for single-family homes with high energy demand as well as commercial users looking to boost their energy independence. Units in this series pair with high-voltage batteries across a wide 150-800V range, giving installers flexibility when matching a storage system to an existing installation, while the transformerless topology keeps losses and footprint low. What sets the series apart is its UPS function with a switching time under 10ms, keeping critical loads powered almost seamlessly during grid outages. In backup mode, the inverter delivers up to 150% peak power overload, making it easier to start motors and other high-inrush loads. Afore AF-TH is one of the few series on the market to support sodium metal chloride batteries, opening the door to cheaper and safer, non-lithium energy storage. Another advantage is time-of-use optimization, which automatically schedules battery charging and discharging around electricity tariffs, while a built-in anti-feed-in function prevents uncontrolled export of surplus power to the grid. An IP66 enclosure and intelligent cooling ensure reliable operation even in demanding outdoor conditions.

Ranking

449 inverters up to 3 kW
Metric This inverter Median Position in class Rank in class
European efficiency 97.5% 96.9% Strong · top 12% 27
MPPT trackers 2 1 Strong · top 22% 6
Max DC input voltage 1000 V 550 V Strong · top 7% 17
Weight per kW 9.7 5.5 Weak · bottom 13% 385
Warranty - 5 yrs Not published -
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Specifications

Open datasheet PDF
Rated AC power 3 kW Continuous output
Max apparent power 4.50 kVA
Phases Three-phase
Nominal AC voltage 230 V
Max AC current 10.5 A
Grid frequency 50 Hz
Power factor 1 (-0.8-0.8) adjustable
Harmonic distortion (THD) 3.0 %
Max DC input power 5.00 kW DC/AC ratio 1.67
Max DC voltage 1000 V Caps the string length
MPPT voltage range 150 to 850 V
Start-up voltage 160 V
MPPT trackers 2 2 strings each
Max input current per MPPT 20.0 A Must exceed the panel's Imp
Max short-circuit current per MPPT 30.0 A Must exceed the panel's Isc
European efficiency 97.5 % Weighted across part loads
Max efficiency 98.0 % Best single operating point
Battery port Yes
Battery voltage 80-600
Max charge current 30.0 A
Max discharge current 30.0 A
Backup power 3.00 kW Output during a grid outage
Grid-forming Yes
Dimensions 535 × 558 × 260 mm Height × width × depth
Weight 29.0 kg 9.7 kg per kW
Enclosure IP65
Cooling forced-air
Operating temperature -25 to 60 °C
Max humidity 100 %
Max altitude 4000 m
Interfaces Wi-FiDisplay
Protocols LCDLEDRS485CANWi-FiGPRS4G
Protection AFCI
Certifications NRS097G98/G99EN50549-1C10/C11AS4777.2VDE-AR-N4105VDE0126IEC62109-1IEC62109-2EN61000-6-2EN61000-6-3

Pros and cons

5 positive · 2 caution
What owners get
Sub-10 ms UPS switchover

The UPS function with a switchover time below 10 ms keeps critical loads essentially uninterrupted during grid outages, a notable advantage over standard hybrid inverters that typically switch in 20-50 ms.

150% overload in backup mode

The ability to run at 150% of peak power in backup mode eases starting of motors, pumps, and other loads with high inrush current, which matters for commercial and industrial applications.

Sodium metal chloride battery support

The AF-TH series, along with the related 3-30 kW lineup, supports sodium metal chloride batteries alongside standard lithium and lead-acid options, enabling access to storage technology independent of lithium pricing and potentially safer thermally.

Wide 150-800 V HV battery voltage range

The 150-800 V high-voltage battery range allows flexible pairing with energy storage units from various manufacturers to an existing installation without requiring a dedicated battery kit.

Time-of-use tariff optimization

Automated charge/discharge scheduling based on time-of-use tariffs, combined with an anti-feed-in function, helps optimize energy costs and prevents uncontrolled export of surplus power to the grid.

Trade-offs
Standard 10-year warranty

Available distributor datasheets indicate a standard 10-year warranty for the TH series, while some tier-1 competitors (e.g., Huawei, Sungrow) offer longer standard terms or paid extension options.

Limited market availability of sodium metal chloride batteries

Despite the declared sodium metal chloride compatibility, the number of energy storage products using this technology currently available on the market remains small compared to lithium-ion, which in practice limits real-world use of this feature by investors.

Alternatives

All Afore inverters
Inverter Power Euro eff. MPPT Weight Difference
Afore AF3K-THA 3 kW 97.5% 2 29.0 kg You are here
SE3000H 3 kW 98.8% - 12.0 kg +1.3 pp efficiency, 17.0 kg lighter
HYX-H3K-HSA2 3 kW 98.2% - 38.0 kg +0.7 pp efficiency, 9.0 kg heavier
Sigen Hybrid 3.0 SP2 3 kW 98.0% 2 11.5 kg +0.5 pp efficiency, 17.5 kg lighter
MOD 3000TL3-HU 3 kW 97.8% 2 19.0 kg 10.0 kg lighter
SPM 3000TL-HU 3 kW 97.6% 2 26.0 kg 3.0 kg lighter
SUN2000L-3KTL 3 kW 97.6% 2 10.6 kg 18.4 kg lighter
MOD 3000TL3-XH 3 kW 97.5% 2 12.5 kg 16.5 kg lighter
AF3K-MTH 3 kW 97.5% 2 22.0 kg 7.0 kg lighter

About the AF-TH series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

Which batteries are compatible with the Afore AF-TH inverter?
The AF-TH series works with high-voltage batteries in the 150-800 V range, giving a lot of flexibility when choosing an energy storage system. In addition, the inverter supports sodium-chloride (sodium-ion type) batteries, offering an alternative to popular lithium-ion storage - typically cheaper and considered safer in terms of fire risk.
How does the UPS function in the Afore AF-TH differ from a regular backup mode?
Standard backup mode in many inverters switches power with a noticeable gap, which can reset computers or routers. The AF-TH has a switchover time of under 10 ms, essentially imperceptible to connected equipment. This means critical circuits, such as servers or medical devices, keep running without interruption even during a grid outage.
Can the AF-TH inverters handle starting a borehole pump motor or other equipment with high startup current?
Yes, in off-grid operation the AF-TH inverter can handle overload up to 150% of peak power. This matters when starting motors, compressors, or pumps that draw significantly more current at startup than during normal operation, so the system won't shut down under a sudden load spike.
What power rating of the Afore AF-TH inverter is suitable for a home versus a business?
The AF-TH series ranges from 36 to 50 kW, which in practice exceeds the needs of a typical household and is better suited to homes with very high energy demand, for example with a heat pump, pool, and EV charging, or to commercial customers and small production businesses.
What does the time-of-use optimization in the AF-TH inverter offer, and does it require manual configuration?
The time-of-use feature lets the inverter automatically schedule battery charging during low electricity price periods and discharging during high price periods, without needing to manually manage the system every day. In practice this translates into lower electricity bills, especially with dynamic tariffs or contracts with time-varying rates.
Does the Afore AF-TH inverter allow exporting surplus energy to the grid, or does it block it?
The AF-TH has a built-in anti-feed-in function that limits or completely blocks uncontrolled export of surplus energy to the grid. This is useful in installations where the grid operator requires zero export, or when the distributor's contract doesn't account for exported energy and the priority is maximizing self-consumption.