Skip to main content
Afore AF10K-MTH

Afore AF10K-MTH

10 kW Hybrid Three-phase Battery-ready
Datasheet PDF
Rated AC (kW)
10.00
Typical for its class
Euro eff. (%)
97.5
Typical · median 97.5%
MPPT
2
Typical · median 2
Max DC (V)
1000
Typical · median 800 V
Weight (kg)
22.0
Typical · median 27.0 kg
Warranty (yrs)
-
Not published

The AF-MTH series brings three-phase energy storage from Afore to homes and businesses that want genuine energy independence, not just lower bills. These inverters work with high-voltage batteries and pair them with flexible 1.5x PV oversizing, letting the system draw the full potential of the array even in weaker irradiance conditions. The standout feature is the UPS function with a switch time under 10 ms, which keeps critical loads running seamlessly during grid outages - a real advantage wherever power interruptions translate into tangible losses. The series supports time-of-use operation and demand charge management, allowing charge and discharge cycles to be planned deliberately around utility rate structures. Another differentiator is support for an external EMS along with generator backup readiness, making the AF-MTH a versatile backup solution for commercial sites as well as residential ones. A compact, highly sealed enclosure, intelligent cooling, and remote firmware updates with smart monitoring simplify both installation and ongoing service, while the wide power range from 3 to 15 kW covers almost any single-family or small commercial setup.

Ranking

839 inverters from 6 to 12 kW
Metric This inverter Median Position in class Rank in class
European efficiency 97.5% 97.5% Typical 268
MPPT trackers 2 2 Typical 145
Max DC input voltage 1000 V 800 V Typical 135
Weight per kW 2.2 3.0 Typical 238
Warranty - 5 yrs Not published -
Colour key Strong - top 25% Typical - middle 50% Weak - bottom 25%

Price offers

1 from shops we track
Shop Country Price Per kW Stock Offer updated Link to shop
tienda-solar.es Spain 1 203.95 € incl. VAT 120.39 €/kW In stock 2d ago Visit shop

Specifications

Open datasheet PDF
Rated AC power 10 kW Continuous output
Max apparent power 15.00 kVA
Phases Three-phase
Nominal AC voltage 400 V
Max AC current 17.0 A
Grid frequency 50 Hz Range 50/60
Power factor -0.8 to 0.8 adjustable
Harmonic distortion (THD) 3.0 %
Max DC input power 15.00 kW DC/AC ratio 1.50
Max DC voltage 1000 V Caps the string length
MPPT voltage range 150 to 850 V
Start-up voltage 160 V
MPPT trackers 2 1 string each
Max input current per MPPT 18.5 A Must exceed the panel's Imp
Max short-circuit current per MPPT 25.0 A Must exceed the panel's Isc
European efficiency 97.5 % Weighted across part loads
Battery port Yes
Battery voltage 80-600
Max charge current 30.0 A
Max discharge current 30.0 A
Dimensions 598 × 370 × 192 mm Height × width × depth
Weight 22.0 kg 2.2 kg per kW
Enclosure IP66
Cooling forced-air
Noise 40 dB
Operating temperature -25 to 60 °C
Max humidity 100 %
Max altitude 4000 m
Interfaces Wi-FiDisplay
Protocols RS485CANWi-FiGPRS4G
Protection AFCISurge protection
Certifications NRS097G98/G99EN50549-1C10/C11AS4777.2VDE-AR-N4105VDE0126IEC62109-1IEC62109-2EN61000-6-2EN61000-6-3

Pros and cons

5 positive · 2 caution
What owners get
Flexible 1.5x PV oversizing

The inverter allows connecting a PV array up to 150% of the inverter's rated AC power, maximizing panel yield even under weak irradiance or suboptimal orientation. This oversizing ratio is more generous than what many tier-2 competitors offer in this power class.

Sub-10 ms UPS switchover

A switchover time below 10 ms to battery backup provides near-seamless power for critical loads (servers, cold storage, medical equipment) during grid outages - a competitive parameter against the 20-30 ms typical of many hybrid inverters in this power range.

EMS integration and generator support

Support for an external EMS plus generator-ready operation lets the AF-MTH act as part of a larger energy management setup for commercial sites, not just residential backup.

Wide 3-15 kW power range

The series spans 3 to 15 kW, covering small prosumer installations as well as larger single-family and small commercial sites within one product family.

Remote monitoring and OTA updates

Remote firmware updates and monitoring reduce the need for on-site service visits, shortening response times and lowering maintenance costs for installers managing multiple units.

Trade-offs
Production discontinued

The AF-MTH series has been discontinued, which limits long-term availability of spare parts and service support - a meaningful risk factor given the 10-15 year lifespan typical of PV-plus-storage installations.

Limited public documentation

Official datasheets and manuals for this specific AF-MTH model are harder to find publicly than for the manufacturer's AF-TH/AF-T series, making independent verification of parameters (e.g., battery voltage window) difficult without contacting the manufacturer or distributor directly.

Alternatives

All Afore inverters
Inverter Power Euro eff. MPPT Weight Difference
Afore AF10K-MTH 10 kW 97.5% 2 22.0 kg You are here
SE10000H 10 kW 99.0% - 19.6 kg +1.5 pp efficiency, 2.4 kg lighter
SigenStor Neo EC 10.0 TP 10 kW 98.7% - 30.0 kg +1.2 pp efficiency, 8.0 kg heavier
Sigen Hybrid 10.0 TP2 10 kW 98.5% 2 19.5 kg +1.0 pp efficiency, 2.5 kg lighter
HYX-H10K-HSA2 10 kW 98.2% - 38.0 kg +0.7 pp efficiency, 16.0 kg heavier
HYX-H10K-HT 10 kW 98.2% 2 34.0 kg +0.7 pp efficiency, 12.0 kg heavier
MOD 10KTL3-XH 10 kW 98.1% 2 14.0 kg +0.6 pp efficiency, 8.0 kg lighter
MOD 10KTL3-HU 10 kW 98.1% 3 20.0 kg +0.6 pp efficiency, +1 MPPT, 2.0 kg lighter
SUN2000-10KTL-M1 10 kW 98.1% 2 17.0 kg +0.6 pp efficiency, 5.0 kg lighter

About the AF-MTH series

6 answered

These answers cover the whole series. Where a figure differs, the specification above is this model's own.

Is the Afore AF-MTH series still available for purchase?
No, production of the AF-MTH series has been discontinued and the inverter has been withdrawn from the manufacturer's lineup. Units may still be found at distributors while stock lasts, but availability is limited. Buyers should contact a distributor to check current stock or consider Afore's current three-phase energy storage inverter models.
How does the UPS function work in the AF-MTH inverter and does it protect against grid outages?
The UPS function in the AF-MTH switches power from the grid to the battery storage in under 10 ms, which is practically imperceptible to connected loads. This means critical equipment such as refrigerators, servers, or medical devices experience no interruption during a grid outage. It is especially valuable in regions with frequent power cuts or in facilities where downtime causes real financial losses.
What does the 1.5x PV oversizing ratio on the AF-MTH mean and what is the benefit?
It means the inverter can accept PV array power up to 1.5 times its rated AC output. This allows the system to make better use of available solar potential even under weaker irradiance, in winter, or with partial shading. In practice, oversizing increases annual energy yield and shortens the payback period without requiring a larger, more expensive inverter.
Does the AF-MTH work with a backup generator and an external EMS?
Yes, the AF-MTH series supports integration with a diesel/gas generator as well as an external Energy Management System (EMS). This enables hybrid power management, such as automatically starting the generator when battery state of charge is low or integrating the storage system into a larger commercial energy setup. This capability is uncommon in residential-class inverters of this power range.
What power range does the AF-MTH series cover and what installations is it suited for?
The AF-MTH series spans models from 3 to 15 kW, making it suitable for single-family homes as well as larger properties and small commercial buildings. The inverters support high-voltage batteries, which simplifies scaling the energy storage system without excessive current draw or transmission losses.
Does the time-of-use mode on the AF-MTH actually help lower electricity bills?
Yes, time-of-use mode allows scheduling battery charging during low-tariff hours and discharging during peak hours when grid electricity is most expensive. The AF-MTH also supports peak shaving to reduce demand charges. Actual savings depend on local tariff structures, but the feature is particularly valuable with dynamic or time-based electricity rates.