Skip to main content
Bi-68-665 vs AB-G12R-132-640 5 of 19 identical Swap Change panels

Waaree Bi-68-665 vs Adani Solar AB-G12R-132-640

Waaree Bi-68-665
Bi-68-665
665 Wp 21.29 % PERC Bifacial
VS
Adani Solar
AB-G12R-132-640
640 Wp 23.71 % TOPCon Bifacial
The verdict

AB-G12R-132-640 leads on the differences that matter

The largest is module efficiency: 2.42 pp more efficient. 5 of 19 comparable parameters are identical.

See all 14 differences
How alike are they
5 of 19 comparable
parameters are identical
identical differs
01

What actually differs

14 of 19 parameters
Parameter Bi-68-665 AB-G12R-132-640 Difference
Module efficiency 21.29 % 23.71 % 2.42 pp more efficient
Temperature coefficient -0.340 %/°C -0.280 %/°C 0.060 %/°C better in heat
Power density 212.8 Wp/m² 237.1 Wp/m² 24.3 Wp/m² higher
Annual degradation 0.55 %/yr 0.40 %/yr 0.15 %/yr slower
Weight 39.0 kg 33.6 kg 5.4 kg lighter
Rated power 665 Wp 640 Wp 25 W more power
Weight per kWp 58.6 kg/kWp 52.5 kg/kWp 6.1 kg/kWp lighter
Module area 3.125 m² 2.699 m² 0.426 m² apart
Short-circuit current 18.03 A 16.09 A 1.94 A apart
Cell technology PERC TOPCon PERC vs TOPCon
Open-circuit voltage 46.58 V 49.06 V 2.48 V apart
Current at max power 17.46 A 15.26 A 2.20 A apart
Voltage at max power 38.10 V 42.00 V 3.90 V apart
Dimensions 2400x1302x35 mm 2382x1133x30 mm 2400x1302x35 mm vs 2382x1133x30 mm
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Bi-68-665
21,552 kWh
AB-G12R-132-640
21,473 kWh
Lifetime gap
79 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario Bi-68-665 AB-G12R-132-640
Standard test conditions 25 °C 100.0% of rated power 665 W 640 W
Cool, bright day 40 °C 94.9% of rated power 631 W 613 W
Typical summer roof 55 °C 89.8% of rated power 597 W 586 W
Hot roof 70 °C 84.7% of rated power 563 W 559 W
03

Full specification

Parameter Bi-68-665 AB-G12R-132-640 Difference
Power and efficiency
Rated power 665 Wp 640 Wp +25 W for Bi-68-665
Module efficiency 21.29 % 23.71 % +2.42 pp for AB-G12R-132-640
Power density 212.8 Wp/m² 237.1 Wp/m² +24.3 Wp/m² for AB-G12R-132-640
Open-circuit voltage 46.58 V 49.06 V 2.48 V apart
Voltage at max power 38.10 V 42.00 V 3.90 V apart
Short-circuit current 18.03 A 16.09 A 1.94 A apart
Current at max power 17.46 A 15.26 A 2.20 A apart
Temperature
Temperature coefficient -0.340 %/°C -0.280 %/°C +0.060 %/°C for AB-G12R-132-640
Mechanical
Dimensions 2400x1302x35 mm 2382x1133x30 mm 2400x1302x35 mm vs 2382x1133x30 mm
Module area 3.125 m² 2.699 m² 0.426 m² apart
Weight 39.0 kg 33.6 kg -5.4 kg for AB-G12R-132-640
Weight per kWp 58.6 kg/kWp 52.5 kg/kWp -6.1 kg/kWp for AB-G12R-132-640
Warranty and degradation
Product warranty 12 yrs 12 yrs Same
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.55 %/yr 0.40 %/yr -0.15 %/yr for AB-G12R-132-640
Technology
Cell technology PERC TOPCon PERC vs TOPCon
Cell type Monocrystalline Monocrystalline Same
Cell count 132 132 Same
Bifacial Yes Yes Same
04

Against the whole database

14,354 panels
Efficiency
#8,926 vs #607
AB-G12R-132-640 leads by 8,319 places
Power density
#8,922 vs #607
AB-G12R-132-640 leads by 8,315 places
Heat behaviour
#9,020 vs #1,409
AB-G12R-132-640 leads by 7,611 places
Weight
#12,091 vs #6,171
AB-G12R-132-640 leads by 5,920 places
Warranty
#31 vs #31
Tied - the same position in the database
Overall
#3,008 vs #1,587
AB-G12R-132-640 leads by 1,421 places
05

More useful comparisons

Open the full database
Same series, other bin
Waaree Bi-68-665 vs Waaree Bi-68-660
The same specification on paper
Same series, other bin
Waaree Bi-68-665 vs Waaree Bi-68-655
3 differences, the largest is module efficiency
Same series, other bin
Waaree Bi-68-665 vs Waaree Bi-68-650
3 differences, the largest is module efficiency
Same series, other bin
Waaree Bi-68-665 vs Waaree Bi-68-645
3 differences, the largest is module efficiency
Same series, other bin
Waaree Bi-68-665 vs Waaree Bi-66-600
8 differences, the largest is rated power
Same series, other bin
Waaree Bi-68-665 vs Waaree Bi-66-595
9 differences, the largest is rated power
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: Waaree Bi-68-665 or Adani Solar AB-G12R-132-640?
According to our database: Adani Solar AB-G12R-132-640 has higher module efficiency (23.71% vs 21.29%); Adani Solar AB-G12R-132-640 tolerates heat better (temp coeff -0.280%/°C vs -0.340%/°C). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Waaree Bi-68-665 and Adani Solar AB-G12R-132-640?
Waaree Bi-68-665 has a module efficiency of 21.29%, while Adani Solar AB-G12R-132-640 is 23.71%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Waaree Bi-68-665 use vs Adani Solar AB-G12R-132-640?
Waaree Bi-68-665 uses PERC cells; Adani Solar AB-G12R-132-640 uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Waaree Bi-68-665 and Adani Solar AB-G12R-132-640?
Waaree Bi-68-665 has a 30 years power warranty; Adani Solar AB-G12R-132-640 has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Waaree Bi-68-665 and Adani Solar AB-G12R-132-640 bifacial panels?
Both Waaree Bi-68-665 and Adani Solar AB-G12R-132-640 are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.
Compare Waaree and Adani Solar as manufacturers Portfolio, efficiency, cell technologies and warranty terms

Shop prices: See 22 Waaree offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.