TCL Zhonghuan HSM-BD54-WA460 vs TCL Zhonghuan HSM-ND66-GK720
VS
The verdict
BD54-WA460 leads on the differences that matter
The largest is rated power: 260 W more power. 4 of 19 comparable parameters are identical.
See all 15 differencesHow alike are they
4
of 19 comparable
parameters are identical
parameters are identical
identical
differs
01
15 of 19 parameters
What actually differs
Parameter
BD54-WA460
ND66-GK720
Difference
Rated power
460 Wp
720 Wp
260 W more power
Weight
21.5 kg
38.2 kg
16.7 kg lighter
Product warranty
25 yrs
15 yrs
10 yrs longer
Temperature coefficient
-0.260 %/°C
-0.280 %/°C
0.020 %/°C better in heat
Weight per kWp
46.7 kg/kWp
53.1 kg/kWp
6.3 kg/kWp lighter
Open-circuit voltage
41.06 V
49.14 V
8.08 V apart
Short-circuit current
14.25 A
18.56 A
4.31 A apart
Module area
1.992 m²
3.106 m²
1.114 m² apart
Cell technology
Back Contact
N-type
Back Contact vs N-type
Annual degradation
0.35 %/yr
0.40 %/yr
0.05 %/yr slower
Voltage at max power
34.62 V
41.08 V
6.46 V apart
Current at max power
13.29 A
17.53 A
4.24 A apart
Cell count
108
132
24 cells apart
Bifacial
No
Yes
No vs Yes
Dimensions
1757x1134x30 mm
2384x1303x33 mm
1757x1134x30 mm vs 2384x1303x33 mm
02
What it means on a roof
Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
BD54-WA460
15,554 kWh
ND66-GK720
24,157 kWh
Lifetime gap
8,603 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
BD54-WA460
ND66-GK720
Standard test conditions
25 °C
100.0% of rated power
460 W
720 W
Cool, bright day
40 °C
95.8% of rated power
442 W
690 W
Typical summer roof
55 °C
91.6% of rated power
424 W
660 W
Hot roof
70 °C
87.4% of rated power
406 W
629 W
03
Full specification
Parameter
BD54-WA460
ND66-GK720
Difference
Power and efficiency
Rated power
460 Wp
720 Wp
+260 W for ND66-GK720
Module efficiency
23.10 %
23.20 %
Effectively the same
Power density
230.9 Wp/m²
231.8 Wp/m²
Effectively the same
Open-circuit voltage
41.06 V
49.14 V
8.08 V apart
Voltage at max power
34.62 V
41.08 V
6.46 V apart
Short-circuit current
14.25 A
18.56 A
4.31 A apart
Current at max power
13.29 A
17.53 A
4.24 A apart
Temperature
Temperature coefficient
-0.260 %/°C
-0.280 %/°C
+0.020 %/°C for BD54-WA460
Mechanical
Dimensions
1757x1134x30 mm
2384x1303x33 mm
1757x1134x30 mm vs 2384x1303x33 mm
Module area
1.992 m²
3.106 m²
1.114 m² apart
Weight
21.5 kg
38.2 kg
-16.7 kg for BD54-WA460
Weight per kWp
46.7 kg/kWp
53.1 kg/kWp
-6.3 kg/kWp for BD54-WA460
Warranty and degradation
Product warranty
25 yrs
15 yrs
+10 yrs for BD54-WA460
Performance warranty
30 yrs
30 yrs
Same
Annual degradation
0.35 %/yr
0.40 %/yr
-0.05 %/yr for BD54-WA460
Technology
Cell technology
Back Contact
N-type
Back Contact vs N-type
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
108
132
24 cells apart
Bifacial
No
Yes
No vs Yes
04
14,005 panels
Against the whole database
Efficiency
#1,570
vs
#1,306
ND66-GK720 leads by 264 places
Power density
#1,638
vs
#1,347
ND66-GK720 leads by 291 places
Heat behaviour
#511
vs
#1,309
BD54-WA460 leads by 798 places
Weight
#1,324
vs
#6,810
BD54-WA460 leads by 5,486 places
Warranty
#21
vs
#21
Tied - the same position in the database
Overall
#5,043
vs
#339
ND66-GK720 leads by 4,704 places
05
Open the full database
More useful comparisons
Same series, other bin
TCL Zhonghuan
TCL Zhonghuan HSM-BD54-WA460 vs TCL Zhonghuan HSM-BD54-WA475
3 differences, the largest is module efficiency
Same series, other bin
TCL Zhonghuan
TCL Zhonghuan HSM-BD54-WA460 vs TCL Zhonghuan HSM-BD54-WA470
3 differences, the largest is module efficiency
Same series, other bin
TCL Zhonghuan
TCL Zhonghuan HSM-BD54-WA460 vs TCL Zhonghuan HSM-BD54-WA465
One difference: module efficiency
Same series, other bin
TCL Zhonghuan
TCL Zhonghuan HSM-ND66-GK720 vs TCL Zhonghuan HSM-ND66-GK725
The same specification on paper
Same series, other bin
TCL Zhonghuan
TCL Zhonghuan HSM-ND66-GK720 vs TCL Zhonghuan HSM-ND66-GK715
One difference: module efficiency
Same series, other bin
TCL Zhonghuan
TCL Zhonghuan HSM-ND66-GK720 vs TCL Zhonghuan HSM-ND66-GK710
3 differences, the largest is module efficiency
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: TCL Zhonghuan HSM-BD54-WA460 or TCL Zhonghuan HSM-ND66-GK720?
According to our database: TCL Zhonghuan HSM-ND66-GK720 has higher module efficiency (23.20% vs 23.10%); TCL Zhonghuan HSM-BD54-WA460 tolerates heat better (temp coeff -0.260%/°C vs -0.280%/°C). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of TCL Zhonghuan HSM-BD54-WA460 and TCL Zhonghuan HSM-ND66-GK720?
TCL Zhonghuan HSM-BD54-WA460 has a module efficiency of 23.10%, while TCL Zhonghuan HSM-ND66-GK720 is 23.20%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does TCL Zhonghuan HSM-BD54-WA460 use vs TCL Zhonghuan HSM-ND66-GK720?
TCL Zhonghuan HSM-BD54-WA460 uses Back Contact cells; TCL Zhonghuan HSM-ND66-GK720 uses N-type. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on TCL Zhonghuan HSM-BD54-WA460 and TCL Zhonghuan HSM-ND66-GK720?
TCL Zhonghuan HSM-BD54-WA460 has a 30 years power warranty; TCL Zhonghuan HSM-ND66-GK720 has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are TCL Zhonghuan HSM-BD54-WA460 and TCL Zhonghuan HSM-ND66-GK720 bifacial panels?
TCL Zhonghuan HSM-ND66-GK720 is bifacial (captures light from both faces); TCL Zhonghuan HSM-BD54-WA460 is monofacial. Bifacial panels work best on ground mounts or raised structures with a light-coloured surface underneath.
Shop prices: See 20 TCL Zhonghuan offers
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.