Skip to main content
TP540HG10B-530 vs TP580LG10B 10 of 19 identical Swap Change panels

Tata Power Solar TP540HG10B-530 vs Tata Power Solar TP580LG10B

Tata Power Solar
TP540HG10B-530
530 Wp 20.52 % PERC Bifacial
VS
Tata Power Solar TP580LG10B
Tata Power Solar
TP580LG10B
580 Wp 20.83 % PERC Bifacial
The verdict

TP580LG10B leads on the differences that matter

The largest is rated power: 50 W more power. 10 of 19 comparable parameters are identical.

See all 9 differences
How alike are they
10 of 19 comparable
parameters are identical
identical differs
01

What actually differs

9 of 19 parameters
Parameter TP540HG10B-530 TP580LG10B Difference
Rated power 530 Wp 580 Wp 50 W more power
Weight 33.0 kg 36.0 kg 3.0 kg lighter
Open-circuit voltage 49.30 V 53.63 V 4.33 V apart
Module area 2.583 m² 2.785 m² 0.202 m² apart
Module efficiency 20.52 % 20.83 % 0.31 pp more efficient
Power density 205.2 Wp/m² 208.3 Wp/m² 3.1 Wp/m² higher
Cell count 144 156 12 cells apart
Voltage at max power 42.20 V 45.97 V 3.77 V apart
Dimensions 2278x1134x35 mm 2456x1134x35 mm 2278x1134x35 mm vs 2456x1134x35 mm
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.370 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
TP540HG10B-530
16,943 kWh
TP580LG10B
18,541 kWh
Lifetime gap
1,598 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario TP540HG10B-530 TP580LG10B
Standard test conditions 25 °C 100.0% of rated power 530 W 580 W
Cool, bright day 40 °C 94.5% of rated power 501 W 548 W
Typical summer roof 55 °C 88.9% of rated power 471 W 516 W
Hot roof 70 °C 83.3% of rated power 442 W 483 W
03

Full specification

Parameter TP540HG10B-530 TP580LG10B Difference
Power and efficiency
Rated power 530 Wp 580 Wp +50 W for TP580LG10B
Module efficiency 20.52 % 20.83 % +0.31 pp for TP580LG10B
Power density 205.2 Wp/m² 208.3 Wp/m² +3.1 Wp/m² for TP580LG10B
Open-circuit voltage 49.30 V 53.63 V 4.33 V apart
Voltage at max power 42.20 V 45.97 V 3.77 V apart
Short-circuit current 13.13 A 13.12 A Effectively the same
Current at max power 12.56 A 12.62 A Effectively the same
Temperature
Temperature coefficient -0.370 %/°C -0.370 %/°C Same
Mechanical
Dimensions 2278x1134x35 mm 2456x1134x35 mm 2278x1134x35 mm vs 2456x1134x35 mm
Module area 2.583 m² 2.785 m² 0.202 m² apart
Weight 33.0 kg 36.0 kg -3.0 kg for TP540HG10B-530
Weight per kWp 62.3 kg/kWp 62.1 kg/kWp Effectively the same
Warranty and degradation
Product warranty 12 yrs 12 yrs Same
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.60 %/yr 0.60 %/yr Same
Technology
Cell technology PERC PERC Same
Cell type Monocrystalline Monocrystalline Same
Cell count 144 156 12 cells apart
Bifacial Yes Yes Same
04

Against the whole database

14,005 panels
Efficiency
#11,244 vs #10,433
TP580LG10B leads by 811 places
Power density
#11,255 vs #10,448
TP580LG10B leads by 807 places
Heat behaviour
#13,081 vs #13,081
Tied - the same position in the database
Weight
#12,757 vs #12,738
TP580LG10B leads by 19 places
Warranty
#21 vs #21
Tied - the same position in the database
Overall
#8,798 vs #6,484
TP580LG10B leads by 2,314 places
05

More useful comparisons

Open the full database
Same series, other bin
Tata Power Solar
Tata Power Solar TP540HG10B-530 vs Tata Power Solar TP590LG10B
9 differences, the largest is module efficiency
Same series, other bin
Tata Power Solar
Tata Power Solar TP540HG10B-530 vs Tata Power Solar TP570LG10B
7 differences, the largest is rated power
Same series, other bin
Tata Power Solar
Tata Power Solar TP540HG10B-530 vs Tata Power Solar TP550HG10TB
9 differences, the largest is module efficiency
Same series, other bin
Tata Power Solar
Tata Power Solar TP540HG10B-530 vs Tata Power Solar TP540HG10B-550
4 differences, the largest is module efficiency
Same series, other bin
Tata Power Solar
Tata Power Solar TP540HG10B-530 vs Tata Power Solar TP545HG10TB
9 differences, the largest is performance warranty
Same series, other bin
Tata Power Solar
Tata Power Solar TP540HG10B-530 vs Tata Power Solar TP540HG10B-545
3 differences, the largest is module efficiency
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: Tata Power Solar TP540HG10B-530 or Tata Power Solar TP580LG10B?
According to our database: Tata Power Solar TP580LG10B has higher module efficiency (20.83% vs 20.52%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Tata Power Solar TP540HG10B-530 and Tata Power Solar TP580LG10B?
Tata Power Solar TP540HG10B-530 has a module efficiency of 20.52%, while Tata Power Solar TP580LG10B is 20.83%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Tata Power Solar TP540HG10B-530 use vs Tata Power Solar TP580LG10B?
Tata Power Solar TP540HG10B-530 uses PERC cells; Tata Power Solar TP580LG10B uses PERC. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Tata Power Solar TP540HG10B-530 and Tata Power Solar TP580LG10B?
Tata Power Solar TP540HG10B-530 has a 30 years power warranty; Tata Power Solar TP580LG10B has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Tata Power Solar TP540HG10B-530 and Tata Power Solar TP580LG10B bifacial panels?
Both Tata Power Solar TP540HG10B-530 and Tata Power Solar TP580LG10B are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.