Skip to main content
TM7G54M/440W vs TM3G54M/510W 11 of 19 identical Swap Change panels

Talesun TM7G54M/440W vs Talesun TM3G54M/510W

Talesun TM7G54M/440W
Talesun
TM7G54M/440W
440 Wp 22.50 % TOPCon Bifacial
VS
Talesun TM3G54M/510W
Talesun
TM3G54M/510W
510 Wp 22.80 % TOPCon Bifacial
The verdict

TM3G54M/510W leads on the differences that matter

The largest is rated power: 70 W more power. 11 of 19 comparable parameters are identical.

See all 8 differences
How alike are they
11 of 19 comparable
parameters are identical
identical differs
01

What actually differs

8 of 19 parameters
Parameter TM7G54M/440W TM3G54M/510W Difference
Rated power 440 Wp 510 Wp 70 W more power
Weight 24.5 kg 28.1 kg 3.6 kg lighter
Short-circuit current 13.77 A 15.91 A 2.14 A apart
Module area 1.953 m² 2.241 m² 0.288 m² apart
Module efficiency 22.50 % 22.80 % 0.30 pp more efficient
Current at max power 13.36 A 15.06 A 1.70 A apart
Open-circuit voltage 39.30 V 40.58 V 1.28 V apart
Dimensions 1722x1134x30 mm 1976x1134x30 mm 1722x1134x30 mm vs 1976x1134x30 mm
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
TM7G54M/440W
14,763 kWh
TM3G54M/510W
17,112 kWh
Lifetime gap
2,349 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario TM7G54M/440W TM3G54M/510W
Standard test conditions 25 °C 100.0% of rated power 440 W 510 W
Cool, bright day 40 °C 95.7% of rated power 421 W 488 W
Typical summer roof 55 °C 91.3% of rated power 402 W 466 W
Hot roof 70 °C 87.0% of rated power 383 W 443 W
03

Full specification

Parameter TM7G54M/440W TM3G54M/510W Difference
Power and efficiency
Rated power 440 Wp 510 Wp +70 W for TM3G54M/510W
Module efficiency 22.50 % 22.80 % +0.30 pp for TM3G54M/510W
Power density 225.3 Wp/m² 227.6 Wp/m² Effectively the same
Open-circuit voltage 39.30 V 40.58 V 1.28 V apart
Voltage at max power 32.94 V 33.87 V Effectively the same
Short-circuit current 13.77 A 15.91 A 2.14 A apart
Current at max power 13.36 A 15.06 A 1.70 A apart
Temperature
Temperature coefficient -0.290 %/°C -0.290 %/°C Same
Mechanical
Dimensions 1722x1134x30 mm 1976x1134x30 mm 1722x1134x30 mm vs 1976x1134x30 mm
Module area 1.953 m² 2.241 m² 0.288 m² apart
Weight 24.5 kg 28.1 kg -3.6 kg for TM7G54M/440W
Weight per kWp 55.7 kg/kWp 55.1 kg/kWp Effectively the same
Warranty and degradation
Product warranty 15 yrs 15 yrs Same
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.40 %/yr 0.40 %/yr Same
Technology
Cell technology TOPCon TOPCon Same
Cell type Monocrystalline Monocrystalline Same
Cell count 108 108 Same
Bifacial Yes Yes Same
04

Against the whole database

14,354 panels
Efficiency
#4,394 vs #2,864
TM3G54M/510W leads by 1,530 places
Power density
#4,268 vs #3,351
TM3G54M/510W leads by 917 places
Heat behaviour
#2,288 vs #2,288
Tied - the same position in the database
Weight
#10,269 vs #9,731
TM3G54M/510W leads by 538 places
Warranty
#31 vs #31
Tied - the same position in the database
Overall
#9,088 vs #6,050
TM3G54M/510W leads by 3,038 places
05

More useful comparisons

Open the full database
Same series, other bin
Talesun
Talesun TM7G54M/440W vs Talesun TM3G54M/505W
7 differences, the largest is rated power
Same series, other bin
Talesun
Talesun TM7G54M/440W vs Talesun TM3G54M/500W
7 differences, the largest is rated power
Same series, other bin
Talesun
Talesun TM7G54M/440W vs Talesun TM3G54M/495W
8 differences, the largest is rated power
Same series, other bin
Talesun
Talesun TM7G54M/440W vs Talesun TM3G54M/490W
8 differences, the largest is rated power
Same series, other bin
Talesun
Talesun TM7G54M/440W vs Talesun TM7G54M/435W
One difference: module efficiency
Same series, other bin
Talesun
Talesun TM7G54M/440W vs Talesun TM7G54M/430W
3 differences, the largest is module efficiency
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: Talesun TM7G54M/440W or Talesun TM3G54M/510W?
According to our database: Talesun TM3G54M/510 W has higher module efficiency (22.80% vs 22.50%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Talesun TM7G54M/440W and Talesun TM3G54M/510W?
Talesun TM7G54M/440 W has a module efficiency of 22.50%, while Talesun TM3G54M/510 W is 22.80%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Talesun TM7G54M/440W use vs Talesun TM3G54M/510W?
Talesun TM7G54M/440 W uses TOPCon cells; Talesun TM3G54M/510 W uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Talesun TM7G54M/440W and Talesun TM3G54M/510W?
Talesun TM7G54M/440 W has a 30 years power warranty; Talesun TM3G54M/510 W has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Talesun TM7G54M/440W and Talesun TM3G54M/510W bifacial panels?
Both Talesun TM7G54M/440 W and Talesun TM3G54M/510 W are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.

Shop prices: See 2 Talesun offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.