Talesun TM7G54M/430W vs Talesun TM3G54M/495W
VS
The verdict
6 differences, and they point both ways
The largest is rated power: 65 W more power. 13 of 19 comparable parameters are identical.
See all 6 differencesHow alike are they
13
of 19 comparable
parameters are identical
parameters are identical
identical
differs
01
6 of 19 parameters
What actually differs
Parameter
TM7G54M/430W
TM3G54M/495W
Difference
Rated power
430 Wp
495 Wp
65 W more power
Weight
24.5 kg
28.1 kg
3.6 kg lighter
Short-circuit current
13.67 A
15.83 A
2.16 A apart
Module area
1.953 m²
2.241 m²
0.288 m² apart
Current at max power
13.16 A
14.94 A
1.78 A apart
Dimensions
1722x1134x30 mm
1976x1134x30 mm
1722x1134x30 mm vs 1976x1134x30 mm
02
What it means on a roof
Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
TM7G54M/430W
14,427 kWh
TM3G54M/495W
16,608 kWh
Lifetime gap
2,181 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
TM7G54M/430W
TM3G54M/495W
Standard test conditions
25 °C
100.0% of rated power
430 W
495 W
Cool, bright day
40 °C
95.7% of rated power
411 W
473 W
Typical summer roof
55 °C
91.3% of rated power
393 W
452 W
Hot roof
70 °C
87.0% of rated power
374 W
430 W
03
Full specification
Parameter
TM7G54M/430W
TM3G54M/495W
Difference
Power and efficiency
Rated power
430 Wp
495 Wp
+65 W for TM3G54M/495W
Module efficiency
22.00 %
22.10 %
Effectively the same
Power density
220.2 Wp/m²
220.9 Wp/m²
Effectively the same
Open-circuit voltage
39.00 V
39.85 V
Effectively the same
Voltage at max power
32.68 V
33.14 V
Effectively the same
Short-circuit current
13.67 A
15.83 A
2.16 A apart
Current at max power
13.16 A
14.94 A
1.78 A apart
Temperature
Temperature coefficient
-0.290 %/°C
-0.290 %/°C
Same
Mechanical
Dimensions
1722x1134x30 mm
1976x1134x30 mm
1722x1134x30 mm vs 1976x1134x30 mm
Module area
1.953 m²
2.241 m²
0.288 m² apart
Weight
24.5 kg
28.1 kg
-3.6 kg for TM7G54M/430W
Weight per kWp
57.0 kg/kWp
56.8 kg/kWp
Effectively the same
Warranty and degradation
Product warranty
15 yrs
15 yrs
Same
Performance warranty
30 yrs
30 yrs
Same
Annual degradation
0.40 %/yr
0.40 %/yr
Same
Technology
Cell technology
TOPCon
TOPCon
Same
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
108
108
Same
Bifacial
Yes
Yes
Same
04
14,354 panels
Against the whole database
Efficiency
#6,713
vs
#6,207
TM3G54M/495W leads by 506 places
Power density
#6,678
vs
#6,204
TM3G54M/495W leads by 474 places
Heat behaviour
#2,288
vs
#2,288
Tied - the same position in the database
Weight
#11,214
vs
#11,099
TM3G54M/495W leads by 115 places
Warranty
#31
vs
#31
Tied - the same position in the database
Overall
#9,916
vs
#7,513
TM3G54M/495W leads by 2,403 places
05
Open the full database
More useful comparisons
Same series, other bin
Talesun
Talesun TM7G54M/430W vs Talesun TM3G54M/510W
10 differences, the largest is module efficiency
Same series, other bin
Talesun
Talesun TM7G54M/430W vs Talesun TM3G54M/505W
9 differences, the largest is rated power
Same series, other bin
Talesun
Talesun TM7G54M/430W vs Talesun TM3G54M/500W
8 differences, the largest is rated power
Same series, other bin
Talesun
Talesun TM7G54M/430W vs Talesun TM3G54M/490W
6 differences, the largest is rated power
Same series, other bin
Talesun
Talesun TM7G54M/430W vs Talesun TM7G54M/440W
3 differences, the largest is module efficiency
Same series, other bin
Talesun
Talesun TM7G54M/430W vs Talesun TM7G54M/435W
One difference: module efficiency
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: Talesun TM7G54M/430W or Talesun TM3G54M/495W?
According to our database: Talesun TM3G54M/495 W has higher module efficiency (22.10% vs 22.00%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Talesun TM7G54M/430W and Talesun TM3G54M/495W?
Talesun TM7G54M/430 W has a module efficiency of 22.00%, while Talesun TM3G54M/495 W is 22.10%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Talesun TM7G54M/430W use vs Talesun TM3G54M/495W?
Talesun TM7G54M/430 W uses TOPCon cells; Talesun TM3G54M/495 W uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Talesun TM7G54M/430W and Talesun TM3G54M/495W?
Talesun TM7G54M/430 W has a 30 years power warranty; Talesun TM3G54M/495 W has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Talesun TM7G54M/430W and Talesun TM3G54M/495W bifacial panels?
Both Talesun TM7G54M/430 W and Talesun TM3G54M/495 W are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.
Shop prices: See 2 Talesun offers
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.