Skip to main content
510W vs 490W 15 of 19 identical Swap Change panels

Talesun TM3G54M/510W vs Talesun TM3G54M/490W

Talesun TM3G54M/510W
Talesun
TM3G54M/510W
510 Wp 22.80 % TOPCon Bifacial
VS
Talesun TM3G54M/490W
Talesun
TM3G54M/490W
490 Wp 21.90 % TOPCon Bifacial
The verdict

510W leads on the differences that matter

The largest is module efficiency: 0.90 pp more efficient. 15 of 19 comparable parameters are identical.

See all 4 differences
How alike are they
15 of 19 comparable
parameters are identical
identical differs
01

What actually differs

4 of 19 parameters
Parameter 510W 490W Difference
Module efficiency 22.80 % 21.90 % 0.90 pp more efficient
Power density 227.6 Wp/m² 218.7 Wp/m² 8.9 Wp/m² higher
Rated power 510 Wp 490 Wp 20 W more power
Weight per kWp 55.1 kg/kWp 57.3 kg/kWp 2.2 kg/kWp lighter
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
510W
17,112 kWh
490W
16,440 kWh
Lifetime gap
672 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario 510W 490W
Standard test conditions 25 °C 100.0% of rated power 510 W 490 W
Cool, bright day 40 °C 95.7% of rated power 488 W 469 W
Typical summer roof 55 °C 91.3% of rated power 466 W 447 W
Hot roof 70 °C 87.0% of rated power 443 W 426 W
03

Full specification

Parameter 510W 490W Difference
Power and efficiency
Rated power 510 Wp 490 Wp +20 W for 510W
Module efficiency 22.80 % 21.90 % +0.90 pp for 510W
Power density 227.6 Wp/m² 218.7 Wp/m² +8.9 Wp/m² for 510W
Open-circuit voltage 40.58 V 39.60 V Effectively the same
Voltage at max power 33.87 V 32.97 V Effectively the same
Short-circuit current 15.91 A 15.80 A Effectively the same
Current at max power 15.06 A 14.86 A Effectively the same
Temperature
Temperature coefficient -0.290 %/°C -0.290 %/°C Same
Mechanical
Dimensions 1976x1134x30 mm 1976x1134x30 mm Same
Module area 2.241 m² 2.241 m² Same
Weight 28.1 kg 28.1 kg Same
Weight per kWp 55.1 kg/kWp 57.3 kg/kWp -2.2 kg/kWp for 510W
Warranty and degradation
Product warranty 15 yrs 15 yrs Same
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.40 %/yr 0.40 %/yr Same
Technology
Cell technology TOPCon TOPCon Same
Cell type Monocrystalline Monocrystalline Same
Cell count 108 108 Same
Bifacial Yes Yes Same
04

Against the whole database

14,354 panels
Efficiency
#2,864 vs #6,987
510W leads by 4,123 places
Power density
#3,351 vs #7,121
510W leads by 3,770 places
Heat behaviour
#2,288 vs #2,288
Tied - the same position in the database
Weight
#9,731 vs #11,437
510W leads by 1,706 places
Warranty
#31 vs #31
Tied - the same position in the database
Overall
#6,050 vs #7,980
510W leads by 1,930 places
05

More useful comparisons

Open the full database
Same series, other bin
Talesun
Talesun TM3G54M/510W vs Talesun TM3G54M/505W
One difference: module efficiency
Same series, other bin
Talesun
Talesun TM3G54M/510W vs Talesun TM3G54M/500W
3 differences, the largest is module efficiency
Same series, other bin
Talesun
Talesun TM3G54M/510W vs Talesun TM3G54M/495W
3 differences, the largest is module efficiency
Same manufacturer
Talesun
Talesun TM3G54M/510W vs Talesun TM8G66M-710
10 differences, the largest is rated power
Same manufacturer
Talesun
Talesun TM3G54M/510W vs Talesun TM8G66M-705
10 differences, the largest is rated power
Same manufacturer
Talesun
Talesun TM3G54M/510W vs Talesun TM8G66M-700
11 differences, the largest is rated power
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: Talesun TM3G54M/510W or Talesun TM3G54M/490W?
According to our database: Talesun TM3G54M/510 W has higher module efficiency (22.80% vs 21.90%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Talesun TM3G54M/510W and Talesun TM3G54M/490W?
Talesun TM3G54M/510 W has a module efficiency of 22.80%, while Talesun TM3G54M/490 W is 21.90%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Talesun TM3G54M/510W use vs Talesun TM3G54M/490W?
Talesun TM3G54M/510 W uses TOPCon cells; Talesun TM3G54M/490 W uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Talesun TM3G54M/510W and Talesun TM3G54M/490W?
Talesun TM3G54M/510 W has a 30 years power warranty; Talesun TM3G54M/490 W has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Talesun TM3G54M/510W and Talesun TM3G54M/490W bifacial panels?
Both Talesun TM3G54M/510 W and Talesun TM3G54M/490 W are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.

Shop prices: See 2 Talesun offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.