Skip to main content
TM3G54M/505W vs TM7G54M/440W 12 of 19 identical Swap Change panels

Talesun TM3G54M/505W vs Talesun TM7G54M/440W

Talesun TM3G54M/505W
Talesun
TM3G54M/505W
505 Wp 22.50 % TOPCon Bifacial
VS
Talesun TM7G54M/440W
Talesun
TM7G54M/440W
440 Wp 22.50 % TOPCon Bifacial
The verdict

7 differences, and they point both ways

The largest is rated power: 65 W more power. 12 of 19 comparable parameters are identical.

See all 7 differences
How alike are they
12 of 19 comparable
parameters are identical
identical differs
01

What actually differs

7 of 19 parameters
Parameter TM3G54M/505W TM7G54M/440W Difference
Rated power 505 Wp 440 Wp 65 W more power
Weight 28.1 kg 24.5 kg 3.6 kg lighter
Short-circuit current 15.89 A 13.77 A 2.12 A apart
Module area 2.241 m² 1.953 m² 0.288 m² apart
Current at max power 15.02 A 13.36 A 1.66 A apart
Open-circuit voltage 40.34 V 39.30 V 1.04 V apart
Dimensions 1976x1134x30 mm 1722x1134x30 mm 1976x1134x30 mm vs 1722x1134x30 mm
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
TM3G54M/505W
16,944 kWh
TM7G54M/440W
14,763 kWh
Lifetime gap
2,181 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario TM3G54M/505W TM7G54M/440W
Standard test conditions 25 °C 100.0% of rated power 505 W 440 W
Cool, bright day 40 °C 95.7% of rated power 483 W 421 W
Typical summer roof 55 °C 91.3% of rated power 461 W 402 W
Hot roof 70 °C 87.0% of rated power 439 W 383 W
03

Full specification

Parameter TM3G54M/505W TM7G54M/440W Difference
Power and efficiency
Rated power 505 Wp 440 Wp +65 W for TM3G54M/505W
Module efficiency 22.50 % 22.50 % Same
Power density 225.4 Wp/m² 225.3 Wp/m² Effectively the same
Open-circuit voltage 40.34 V 39.30 V 1.04 V apart
Voltage at max power 33.63 V 32.94 V Effectively the same
Short-circuit current 15.89 A 13.77 A 2.12 A apart
Current at max power 15.02 A 13.36 A 1.66 A apart
Temperature
Temperature coefficient -0.290 %/°C -0.290 %/°C Same
Mechanical
Dimensions 1976x1134x30 mm 1722x1134x30 mm 1976x1134x30 mm vs 1722x1134x30 mm
Module area 2.241 m² 1.953 m² 0.288 m² apart
Weight 28.1 kg 24.5 kg -3.6 kg for TM7G54M/440W
Weight per kWp 55.6 kg/kWp 55.7 kg/kWp Effectively the same
Warranty and degradation
Product warranty 15 yrs 15 yrs Same
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.40 %/yr 0.40 %/yr Same
Technology
Cell technology TOPCon TOPCon Same
Cell type Monocrystalline Monocrystalline Same
Cell count 108 108 Same
Bifacial Yes Yes Same
04

Against the whole database

14,354 panels
Efficiency
#4,394 vs #4,394
Tied - the same position in the database
Power density
#4,142 vs #4,268
TM3G54M/505W leads by 126 places
Heat behaviour
#2,288 vs #2,288
Tied - the same position in the database
Weight
#10,225 vs #10,269
TM3G54M/505W leads by 44 places
Warranty
#31 vs #31
Tied - the same position in the database
Overall
#6,638 vs #9,088
TM3G54M/505W leads by 2,450 places
05

More useful comparisons

Open the full database
Same series, other bin
Talesun
Talesun TM3G54M/505W vs Talesun TM3G54M/510W
One difference: module efficiency
Same series, other bin
Talesun
Talesun TM3G54M/505W vs Talesun TM3G54M/500W
One difference: module efficiency
Same series, other bin
Talesun
Talesun TM3G54M/505W vs Talesun TM3G54M/495W
3 differences, the largest is module efficiency
Same series, other bin
Talesun
Talesun TM3G54M/505W vs Talesun TM3G54M/490W
3 differences, the largest is module efficiency
Same series, other bin
Talesun
Talesun TM7G54M/440W vs Talesun TM7G54M/435W
One difference: module efficiency
Same series, other bin
Talesun
Talesun TM7G54M/440W vs Talesun TM7G54M/430W
3 differences, the largest is module efficiency
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: Talesun TM3G54M/505W or Talesun TM7G54M/440W?
According to our database: both panels are closely matched on key specs - the decision often comes down to price and local availability. See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Talesun TM3G54M/505W and Talesun TM7G54M/440W?
Talesun TM3G54M/505 W has a module efficiency of 22.50%, while Talesun TM7G54M/440 W is 22.50%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Talesun TM3G54M/505W use vs Talesun TM7G54M/440W?
Talesun TM3G54M/505 W uses TOPCon cells; Talesun TM7G54M/440 W uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Talesun TM3G54M/505W and Talesun TM7G54M/440W?
Talesun TM3G54M/505 W has a 30 years power warranty; Talesun TM7G54M/440 W has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Talesun TM3G54M/505W and Talesun TM7G54M/440W bifacial panels?
Both Talesun TM3G54M/505 W and Talesun TM7G54M/440 W are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.

Shop prices: See 2 Talesun offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.