Talesun TM3G54M/500W vs Talesun TM7G54M/440W
VS
The verdict
7 differences, and they point both ways
The largest is rated power: 60 W more power. 12 of 19 comparable parameters are identical.
See all 7 differencesHow alike are they
12
of 19 comparable
parameters are identical
parameters are identical
identical
differs
01
7 of 19 parameters
What actually differs
Parameter
TM3G54M/500W
TM7G54M/440W
Difference
Rated power
500 Wp
440 Wp
60 W more power
Weight
28.1 kg
24.5 kg
3.6 kg lighter
Short-circuit current
15.86 A
13.77 A
2.09 A apart
Module area
2.241 m²
1.953 m²
0.288 m² apart
Module efficiency
22.30 %
22.50 %
0.20 pp more efficient
Current at max power
14.98 A
13.36 A
1.62 A apart
Dimensions
1976x1134x30 mm
1722x1134x30 mm
1976x1134x30 mm vs 1722x1134x30 mm
02
What it means on a roof
Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
TM3G54M/500W
16,776 kWh
TM7G54M/440W
14,763 kWh
Lifetime gap
2,013 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
TM3G54M/500W
TM7G54M/440W
Standard test conditions
25 °C
100.0% of rated power
500 W
440 W
Cool, bright day
40 °C
95.7% of rated power
478 W
421 W
Typical summer roof
55 °C
91.3% of rated power
457 W
402 W
Hot roof
70 °C
87.0% of rated power
435 W
383 W
03
Full specification
Parameter
TM3G54M/500W
TM7G54M/440W
Difference
Power and efficiency
Rated power
500 Wp
440 Wp
+60 W for TM3G54M/500W
Module efficiency
22.30 %
22.50 %
+0.20 pp for TM7G54M/440W
Power density
223.1 Wp/m²
225.3 Wp/m²
Effectively the same
Open-circuit voltage
40.09 V
39.30 V
Effectively the same
Voltage at max power
33.38 V
32.94 V
Effectively the same
Short-circuit current
15.86 A
13.77 A
2.09 A apart
Current at max power
14.98 A
13.36 A
1.62 A apart
Temperature
Temperature coefficient
-0.290 %/°C
-0.290 %/°C
Same
Mechanical
Dimensions
1976x1134x30 mm
1722x1134x30 mm
1976x1134x30 mm vs 1722x1134x30 mm
Module area
2.241 m²
1.953 m²
0.288 m² apart
Weight
28.1 kg
24.5 kg
-3.6 kg for TM7G54M/440W
Weight per kWp
56.2 kg/kWp
55.7 kg/kWp
Effectively the same
Warranty and degradation
Product warranty
15 yrs
15 yrs
Same
Performance warranty
30 yrs
30 yrs
Same
Annual degradation
0.40 %/yr
0.40 %/yr
Same
Technology
Cell technology
TOPCon
TOPCon
Same
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
108
108
Same
Bifacial
Yes
Yes
Same
04
14,354 panels
Against the whole database
Efficiency
#5,284
vs
#4,394
TM7G54M/440W leads by 890 places
Power density
#5,252
vs
#4,268
TM7G54M/440W leads by 984 places
Heat behaviour
#2,288
vs
#2,288
Tied - the same position in the database
Weight
#10,720
vs
#10,269
TM7G54M/440W leads by 451 places
Warranty
#31
vs
#31
Tied - the same position in the database
Overall
#7,069
vs
#9,088
TM3G54M/500W leads by 2,019 places
05
Open the full database
More useful comparisons
Same series, other bin
Talesun
Talesun TM3G54M/500W vs Talesun TM3G54M/510W
3 differences, the largest is module efficiency
Same series, other bin
Talesun
Talesun TM3G54M/500W vs Talesun TM3G54M/505W
One difference: module efficiency
Same series, other bin
Talesun
Talesun TM3G54M/500W vs Talesun TM3G54M/495W
One difference: module efficiency
Same series, other bin
Talesun
Talesun TM3G54M/500W vs Talesun TM3G54M/490W
3 differences, the largest is module efficiency
Same series, other bin
Talesun
Talesun TM7G54M/440W vs Talesun TM7G54M/435W
One difference: module efficiency
Same series, other bin
Talesun
Talesun TM7G54M/440W vs Talesun TM7G54M/430W
3 differences, the largest is module efficiency
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: Talesun TM3G54M/500W or Talesun TM7G54M/440W?
According to our database: Talesun TM7G54M/440 W has higher module efficiency (22.50% vs 22.30%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Talesun TM3G54M/500W and Talesun TM7G54M/440W?
Talesun TM3G54M/500 W has a module efficiency of 22.30%, while Talesun TM7G54M/440 W is 22.50%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Talesun TM3G54M/500W use vs Talesun TM7G54M/440W?
Talesun TM3G54M/500 W uses TOPCon cells; Talesun TM7G54M/440 W uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Talesun TM3G54M/500W and Talesun TM7G54M/440W?
Talesun TM3G54M/500 W has a 30 years power warranty; Talesun TM7G54M/440 W has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Talesun TM3G54M/500W and Talesun TM7G54M/440W bifacial panels?
Both Talesun TM3G54M/500 W and Talesun TM7G54M/440 W are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.
Shop prices: See 2 Talesun offers
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.