Skip to main content
TM3G54M/490W vs TM7G54M/430W 13 of 19 identical Swap Change panels

Talesun TM3G54M/490W vs Talesun TM7G54M/430W

Talesun TM3G54M/490W
Talesun
TM3G54M/490W
490 Wp 21.90 % TOPCon Bifacial
VS
Talesun TM7G54M/430W
Talesun
TM7G54M/430W
430 Wp 22.00 % TOPCon Bifacial
The verdict

6 differences, and they point both ways

The largest is rated power: 60 W more power. 13 of 19 comparable parameters are identical.

See all 6 differences
How alike are they
13 of 19 comparable
parameters are identical
identical differs
01

What actually differs

6 of 19 parameters
Parameter TM3G54M/490W TM7G54M/430W Difference
Rated power 490 Wp 430 Wp 60 W more power
Weight 28.1 kg 24.5 kg 3.6 kg lighter
Short-circuit current 15.80 A 13.67 A 2.13 A apart
Module area 2.241 m² 1.953 m² 0.288 m² apart
Current at max power 14.86 A 13.16 A 1.70 A apart
Dimensions 1976x1134x30 mm 1722x1134x30 mm 1976x1134x30 mm vs 1722x1134x30 mm
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.290 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
TM3G54M/490W
16,440 kWh
TM7G54M/430W
14,427 kWh
Lifetime gap
2,013 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario TM3G54M/490W TM7G54M/430W
Standard test conditions 25 °C 100.0% of rated power 490 W 430 W
Cool, bright day 40 °C 95.7% of rated power 469 W 411 W
Typical summer roof 55 °C 91.3% of rated power 447 W 393 W
Hot roof 70 °C 87.0% of rated power 426 W 374 W
03

Full specification

Parameter TM3G54M/490W TM7G54M/430W Difference
Power and efficiency
Rated power 490 Wp 430 Wp +60 W for TM3G54M/490W
Module efficiency 21.90 % 22.00 % Effectively the same
Power density 218.7 Wp/m² 220.2 Wp/m² Effectively the same
Open-circuit voltage 39.60 V 39.00 V Effectively the same
Voltage at max power 32.97 V 32.68 V Effectively the same
Short-circuit current 15.80 A 13.67 A 2.13 A apart
Current at max power 14.86 A 13.16 A 1.70 A apart
Temperature
Temperature coefficient -0.290 %/°C -0.290 %/°C Same
Mechanical
Dimensions 1976x1134x30 mm 1722x1134x30 mm 1976x1134x30 mm vs 1722x1134x30 mm
Module area 2.241 m² 1.953 m² 0.288 m² apart
Weight 28.1 kg 24.5 kg -3.6 kg for TM7G54M/430W
Weight per kWp 57.3 kg/kWp 57.0 kg/kWp Effectively the same
Warranty and degradation
Product warranty 15 yrs 15 yrs Same
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.40 %/yr 0.40 %/yr Same
Technology
Cell technology TOPCon TOPCon Same
Cell type Monocrystalline Monocrystalline Same
Cell count 108 108 Same
Bifacial Yes Yes Same
04

Against the whole database

14,354 panels
Efficiency
#6,987 vs #6,713
TM7G54M/430W leads by 274 places
Power density
#7,121 vs #6,678
TM7G54M/430W leads by 443 places
Heat behaviour
#2,288 vs #2,288
Tied - the same position in the database
Weight
#11,437 vs #11,214
TM7G54M/430W leads by 223 places
Warranty
#31 vs #31
Tied - the same position in the database
Overall
#7,980 vs #9,916
TM3G54M/490W leads by 1,936 places
05

More useful comparisons

Open the full database
Same series, other bin
Talesun
Talesun TM3G54M/490W vs Talesun TM3G54M/510W
4 differences, the largest is module efficiency
Same series, other bin
Talesun
Talesun TM3G54M/490W vs Talesun TM3G54M/505W
3 differences, the largest is module efficiency
Same series, other bin
Talesun
Talesun TM3G54M/490W vs Talesun TM3G54M/500W
3 differences, the largest is module efficiency
Same series, other bin
Talesun
Talesun TM3G54M/490W vs Talesun TM3G54M/495W
One difference: module efficiency
Same series, other bin
Talesun
Talesun TM7G54M/430W vs Talesun TM7G54M/440W
3 differences, the largest is module efficiency
Same series, other bin
Talesun
Talesun TM7G54M/430W vs Talesun TM7G54M/435W
One difference: module efficiency
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: Talesun TM3G54M/490W or Talesun TM7G54M/430W?
According to our database: Talesun TM7G54M/430 W has higher module efficiency (22.00% vs 21.90%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Talesun TM3G54M/490W and Talesun TM7G54M/430W?
Talesun TM3G54M/490 W has a module efficiency of 21.90%, while Talesun TM7G54M/430 W is 22.00%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Talesun TM3G54M/490W use vs Talesun TM7G54M/430W?
Talesun TM3G54M/490 W uses TOPCon cells; Talesun TM7G54M/430 W uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Talesun TM3G54M/490W and Talesun TM7G54M/430W?
Talesun TM3G54M/490 W has a 30 years power warranty; Talesun TM7G54M/430 W has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Talesun TM3G54M/490W and Talesun TM7G54M/430W bifacial panels?
Both Talesun TM3G54M/490 W and Talesun TM7G54M/430 W are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.

Shop prices: See 2 Talesun offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.