Skip to main content
TD7G72M/540W vs TM8G66M-710 6 of 19 identical Swap Change panels

Talesun TD7G72M/540W vs Talesun TM8G66M-710

Talesun TD7G72M/540W
Talesun
TD7G72M/540W
540 Wp 20.90 % PERC Bifacial
VS
Talesun TM8G66M-710
Talesun
TM8G66M-710
710 Wp 22.90 % TOPCon Bifacial
The verdict

TM8G66M-710 leads on the differences that matter

The largest is module efficiency: 2.00 pp more efficient. 6 of 19 comparable parameters are identical.

See all 13 differences
How alike are they
6 of 19 comparable
parameters are identical
identical differs
01

What actually differs

13 of 19 parameters
Parameter TD7G72M/540W TM8G66M-710 Difference
Module efficiency 20.90 % 22.90 % 2.00 pp more efficient
Temperature coefficient -0.350 %/°C -0.290 %/°C 0.060 %/°C better in heat
Rated power 540 Wp 710 Wp 170 W more power
Power density 209.0 Wp/m² 228.6 Wp/m² 19.5 Wp/m² higher
Weight 31.8 kg 38.5 kg 6.7 kg lighter
Short-circuit current 13.86 A 18.40 A 4.54 A apart
Module area 2.583 m² 3.106 m² 0.523 m² apart
Weight per kWp 58.9 kg/kWp 54.2 kg/kWp 4.7 kg/kWp lighter
Cell technology PERC TOPCon PERC vs TOPCon
Current at max power 12.97 A 17.36 A 4.39 A apart
Cell count 144 132 12 cells apart
Annual degradation 0.45 %/yr 0.40 %/yr 0.05 %/yr slower
Dimensions 2278x1134x30 mm 2384x1303x33 mm 2278x1134x30 mm vs 2384x1303x33 mm
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
TD7G72M/540W
17,783 kWh
TM8G66M-710
23,822 kWh
Lifetime gap
6,039 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario TD7G72M/540W TM8G66M-710
Standard test conditions 25 °C 100.0% of rated power 540 W 710 W
Cool, bright day 40 °C 94.8% of rated power 512 W 679 W
Typical summer roof 55 °C 89.5% of rated power 483 W 648 W
Hot roof 70 °C 84.2% of rated power 455 W 617 W
03

Full specification

Parameter TD7G72M/540W TM8G66M-710 Difference
Power and efficiency
Rated power 540 Wp 710 Wp +170 W for TM8G66M-710
Module efficiency 20.90 % 22.90 % +2.00 pp for TM8G66M-710
Power density 209.0 Wp/m² 228.6 Wp/m² +19.5 Wp/m² for TM8G66M-710
Open-circuit voltage 49.60 V 49.00 V Effectively the same
Voltage at max power 41.64 V 40.90 V Effectively the same
Short-circuit current 13.86 A 18.40 A 4.54 A apart
Current at max power 12.97 A 17.36 A 4.39 A apart
Temperature
Temperature coefficient -0.350 %/°C -0.290 %/°C +0.060 %/°C for TM8G66M-710
Mechanical
Dimensions 2278x1134x30 mm 2384x1303x33 mm 2278x1134x30 mm vs 2384x1303x33 mm
Module area 2.583 m² 3.106 m² 0.523 m² apart
Weight 31.8 kg 38.5 kg -6.7 kg for TD7G72M/540W
Weight per kWp 58.9 kg/kWp 54.2 kg/kWp -4.7 kg/kWp for TM8G66M-710
Warranty and degradation
Product warranty 12 yrs 12 yrs Same
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.45 %/yr 0.40 %/yr -0.05 %/yr for TM8G66M-710
Technology
Cell technology PERC TOPCon PERC vs TOPCon
Cell type Monocrystalline Monocrystalline Same
Cell count 144 132 12 cells apart
Bifacial Yes Yes Same
04

Against the whole database

14,843 panels
Efficiency
#10,767 vs #2,784
TM8G66M-710 leads by 7,983 places
Power density
#10,795 vs #2,910
TM8G66M-710 leads by 7,885 places
Heat behaviour
#11,134 vs #2,527
TM8G66M-710 leads by 8,607 places
Weight
#12,645 vs #9,052
TM8G66M-710 leads by 3,593 places
Warranty
#32 vs #32
Tied - the same position in the database
Overall
#8,463 vs #926
TM8G66M-710 leads by 7,537 places
05

More useful comparisons

Open the full database
Same series, other bin
Talesun
Talesun TD7G72M/540W vs Talesun TD7G72M/550W
3 differences, the largest is module efficiency
Same series, other bin
Talesun
Talesun TD7G72M/540W vs Talesun TD7G72M/545W
One difference: module efficiency
Same series, other bin
Talesun
Talesun TD7G72M/540W vs Talesun TD7G72M/535W
One difference: module efficiency
Same series, other bin
Talesun
Talesun TD7G72M/540W vs Talesun TD7G72M/530W
3 differences, the largest is module efficiency
Same series, other bin
Talesun
Talesun TM8G66M-710 vs Talesun TM8G66M-705
One difference: module efficiency
Same series, other bin
Talesun
Talesun TM8G66M-710 vs Talesun TM8G66M-700
3 differences, the largest is module efficiency
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: Talesun TD7G72M/540W or Talesun TM8G66M-710?
According to our database: Talesun TM8G66M-710 has higher module efficiency (22.90% vs 20.90%); Talesun TM8G66M-710 tolerates heat better (temp coeff -0.290%/°C vs -0.350%/°C). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Talesun TD7G72M/540W and Talesun TM8G66M-710?
Talesun TD7G72M/540 W has a module efficiency of 20.90%, while Talesun TM8G66M-710 is 22.90%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Talesun TD7G72M/540W use vs Talesun TM8G66M-710?
Talesun TD7G72M/540 W uses PERC cells; Talesun TM8G66M-710 uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Talesun TD7G72M/540W and Talesun TM8G66M-710?
Talesun TD7G72M/540 W has a 30 years power warranty; Talesun TM8G66M-710 has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Talesun TD7G72M/540W and Talesun TM8G66M-710 bifacial panels?
Both Talesun TD7G72M/540 W and Talesun TM8G66M-710 are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.

Shop prices: See 1 Talesun offer

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.