Sunpro Power SPDG500-N108R12 vs AIKO AIKO-A485-MAH54Mw
VS
The verdict
AIKO-A485-MAH54Mw leads on the differences that matter
The largest is module efficiency: 1.80 pp more efficient. 4 of 19 comparable parameters are identical.
See all 15 differencesHow alike are they
4
of 19 comparable
parameters are identical
parameters are identical
identical
differs
01
15 of 19 parameters
What actually differs
Parameter
SPDG500-N108R12
AIKO-A485-MAH54Mw
Difference
Module efficiency
22.50 %
24.30 %
1.80 pp more efficient
Temperature coefficient
-0.300 %/°C
-0.260 %/°C
0.040 %/°C better in heat
Power density
225.0 Wp/m²
243.4 Wp/m²
18.5 Wp/m² higher
Weight
26.6 kg
21.5 kg
5.1 kg lighter
Weight per kWp
53.2 kg/kWp
44.3 kg/kWp
8.9 kg/kWp lighter
Module area
2.223 m²
1.992 m²
0.230 m² apart
Rated power
500 Wp
485 Wp
15 W more power
Short-circuit current
15.83 A
14.41 A
1.42 A apart
Cell technology
TOPCon
Back Contact
TOPCon vs Back Contact
Annual degradation
0.40 %/yr
0.35 %/yr
0.05 %/yr slower
Bifacial
Yes
No
Yes vs No
Open-circuit voltage
40.01 V
41.36 V
1.35 V apart
Current at max power
14.98 A
13.90 A
1.08 A apart
Dimensions
1960x1134x30 mm
1757x1134x30 mm
1960x1134x30 mm vs 1757x1134x30 mm
Voltage at max power
33.38 V
34.92 V
1.54 V apart
02
What it means on a roof
Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
SPDG500-N108R12
16,776 kWh
AIKO-A485-MAH54Mw
16,399 kWh
Lifetime gap
377 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
SPDG500-N108R12
AIKO-A485-MAH54Mw
Standard test conditions
25 °C
100.0% of rated power
500 W
485 W
Cool, bright day
40 °C
95.5% of rated power
478 W
466 W
Typical summer roof
55 °C
91.0% of rated power
455 W
447 W
Hot roof
70 °C
86.5% of rated power
433 W
428 W
03
Full specification
Parameter
SPDG500-N108R12
AIKO-A485-MAH54Mw
Difference
Power and efficiency
Rated power
500 Wp
485 Wp
+15 W for SPDG500-N108R12
Module efficiency
22.50 %
24.30 %
+1.80 pp for AIKO-A485-MAH54Mw
Power density
225.0 Wp/m²
243.4 Wp/m²
+18.5 Wp/m² for AIKO-A485-MAH54Mw
Open-circuit voltage
40.01 V
41.36 V
1.35 V apart
Voltage at max power
33.38 V
34.92 V
1.54 V apart
Short-circuit current
15.83 A
14.41 A
1.42 A apart
Current at max power
14.98 A
13.90 A
1.08 A apart
Temperature
Temperature coefficient
-0.300 %/°C
-0.260 %/°C
+0.040 %/°C for AIKO-A485-MAH54Mw
Mechanical
Dimensions
1960x1134x30 mm
1757x1134x30 mm
1960x1134x30 mm vs 1757x1134x30 mm
Module area
2.223 m²
1.992 m²
0.230 m² apart
Weight
26.6 kg
21.5 kg
-5.1 kg for AIKO-A485-MAH54Mw
Weight per kWp
53.2 kg/kWp
44.3 kg/kWp
-8.9 kg/kWp for AIKO-A485-MAH54Mw
Warranty and degradation
Product warranty
25 yrs
25 yrs
Same
Performance warranty
30 yrs
30 yrs
Same
Annual degradation
0.40 %/yr
0.35 %/yr
-0.05 %/yr for AIKO-A485-MAH54Mw
Technology
Cell technology
TOPCon
Back Contact
TOPCon vs Back Contact
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
108
108
Same
Bifacial
Yes
No
Yes vs No
04
14,354 panels
Against the whole database
Efficiency
#4,394
vs
#173
AIKO-A485-MAH54Mw leads by 4,221 places
Power density
#4,629
vs
#173
AIKO-A485-MAH54Mw leads by 4,456 places
Heat behaviour
#6,298
vs
#521
AIKO-A485-MAH54Mw leads by 5,777 places
Weight
#7,199
vs
#430
AIKO-A485-MAH54Mw leads by 6,769 places
Warranty
#31
vs
#31
Tied - the same position in the database
Overall
#4,649
vs
#2,932
AIKO-A485-MAH54Mw leads by 1,717 places
05
Open the full database
More useful comparisons
Same series, other bin
Sunpro Power
Sunpro Power SPDG500-N108R12 vs Sunpro Power SPDG635-N132R12
10 differences, the largest is module efficiency
Same series, other bin
Sunpro Power
Sunpro Power SPDG500-N108R12 vs Sunpro Power SPDG630-N132R12
9 differences, the largest is module efficiency
Same series, other bin
Sunpro Power
Sunpro Power SPDG500-N108R12 vs Sunpro Power SPDG625-N132R12
9 differences, the largest is module efficiency
Same series, other bin
Sunpro Power
Sunpro Power SPDG500-N108R12 vs Sunpro Power SPDG620-N132R12
9 differences, the largest is rated power
Same series, other bin
Sunpro Power
Sunpro Power SPDG500-N108R12 vs Sunpro Power SPDG575-N120R12
9 differences, the largest is module efficiency
Same series, other bin
Sunpro Power
Sunpro Power SPDG500-N108R12 vs Sunpro Power SPDG570-N120R12
9 differences, the largest is module efficiency
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: Sunpro Power SPDG500-N108R12 or AIKO AIKO-A485-MAH54Mw?
According to our database: AIKO AIKO-A485-MAH54Mw has higher module efficiency (24.30% vs 22.50%); AIKO AIKO-A485-MAH54Mw tolerates heat better (temp coeff -0.260%/°C vs -0.300%/°C). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Sunpro Power SPDG500-N108R12 and AIKO AIKO-A485-MAH54Mw?
Sunpro Power SPDG500-N108R12 has a module efficiency of 22.50%, while AIKO AIKO-A485-MAH54Mw is 24.30%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Sunpro Power SPDG500-N108R12 use vs AIKO AIKO-A485-MAH54Mw?
Sunpro Power SPDG500-N108R12 uses TOPCon cells; AIKO AIKO-A485-MAH54Mw uses Back Contact. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Sunpro Power SPDG500-N108R12 and AIKO AIKO-A485-MAH54Mw?
Sunpro Power SPDG500-N108R12 has a 30 years power warranty; AIKO AIKO-A485-MAH54Mw has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Sunpro Power SPDG500-N108R12 and AIKO AIKO-A485-MAH54Mw bifacial panels?
Sunpro Power SPDG500-N108R12 is bifacial (captures light from both faces); AIKO AIKO-A485-MAH54Mw is monofacial. Bifacial panels work best on ground mounts or raised structures with a light-coloured surface underneath.
Shop prices: See 8 Sunpro Power offers · See 147 AIKO offers
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.