Solaria Solaria PowerX-400R vs Solaria SPV680-TG12-132BD
VS
The verdict
SPV680-TG12-132BD leads on the differences that matter
The largest is module efficiency: 1.42 pp more efficient. 2 of 16 comparable parameters are identical, with 3 more left out because at least one datasheet does not publish them.
See all 14 differencesHow alike are they
2
of 16 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
14 of 16 parameters
What actually differs
Parameter
Solaria PowerX-400R
SPV680-TG12-132BD
Difference
Module efficiency
20.50 %
21.92 %
1.42 pp more efficient
Temperature coefficient
-0.360 %/°C
-0.300 %/°C
0.060 %/°C better in heat
Rated power
400 Wp
680 Wp
280 W more power
Power density
204.7 Wp/m²
219.2 Wp/m²
14.4 Wp/m² higher
Performance warranty
25 yrs
30 yrs
5 yrs longer
Weight
22.1 kg
38.0 kg
15.9 kg lighter
Product warranty
25 yrs
12 yrs
13 yrs longer
Open-circuit voltage
37.30 V
46.90 V
9.60 V apart
Short-circuit current
13.68 A
17.96 A
4.28 A apart
Module area
1.954 m²
3.103 m²
1.149 m² apart
Voltage at max power
31.00 V
39.63 V
8.63 V apart
Current at max power
12.90 A
17.18 A
4.28 A apart
Bifacial
No
Yes
No vs Yes
Dimensions
1723x1134x35 mm
2383x1302x30 mm
1723x1134x35 mm vs 2383x1302x30 mm
02
What it means on a roof
Thirty years of production
Declared first-year losses, with 0.40% a year afterwards assumed for both panels, at 1,200 kWh/kWp a year
Solaria PowerX-400R
13,277 kWh
SPV680-TG12-132BD
22,571 kWh
Lifetime gap
9,294 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
Solaria PowerX-400R
SPV680-TG12-132BD
Standard test conditions
25 °C
100.0% of rated power
400 W
680 W
Cool, bright day
40 °C
94.6% of rated power
378 W
649 W
Typical summer roof
55 °C
89.2% of rated power
357 W
619 W
Hot roof
70 °C
83.8% of rated power
335 W
588 W
03
Full specification
Parameter
Solaria PowerX-400R
SPV680-TG12-132BD
Difference
Power and efficiency
Rated power
400 Wp
680 Wp
+280 W for SPV680-TG12-132BD
Module efficiency
20.50 %
21.92 %
+1.42 pp for SPV680-TG12-132BD
Power density
204.7 Wp/m²
219.2 Wp/m²
+14.4 Wp/m² for SPV680-TG12-132BD
Open-circuit voltage
37.30 V
46.90 V
9.60 V apart
Voltage at max power
31.00 V
39.63 V
8.63 V apart
Short-circuit current
13.68 A
17.96 A
4.28 A apart
Current at max power
12.90 A
17.18 A
4.28 A apart
Temperature
Temperature coefficient
-0.360 %/°C
-0.300 %/°C
+0.060 %/°C for SPV680-TG12-132BD
Mechanical
Dimensions
1723x1134x35 mm
2383x1302x30 mm
1723x1134x35 mm vs 2383x1302x30 mm
Module area
1.954 m²
3.103 m²
1.149 m² apart
Weight
22.1 kg
38.0 kg
-15.9 kg for Solaria PowerX-400R
Weight per kWp
55.2 kg/kWp
55.9 kg/kWp
Effectively the same
Warranty and degradation
Product warranty
25 yrs
12 yrs
+13 yrs for Solaria PowerX-400R
Performance warranty
25 yrs
30 yrs
+5 yrs for SPV680-TG12-132BD
Annual degradation
0.50 %/yr
-
Not published by Solaria
Technology
Cell technology
-
TOPCon
Not published by Solaria
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
-
132
Not published by Solaria
Bifacial
No
Yes
No vs Yes
04
14,005 panels
Against the whole database
Efficiency
#11,308
vs
#6,767
SPV680-TG12-132BD leads by 4,541 places
Power density
#11,499
vs
#6,738
SPV680-TG12-132BD leads by 4,761 places
Heat behaviour
#12,345
vs
#6,093
SPV680-TG12-132BD leads by 6,252 places
Weight
#9,691
vs
#10,244
Solaria PowerX-400R leads by 553 places
Warranty
#9,798
vs
#21
SPV680-TG12-132BD leads by 9,777 places
Overall
#10,732
vs
#1,903
SPV680-TG12-132BD leads by 8,829 places
05
Open the full database
More useful comparisons
Same series, other bin
Solaria
Solaria Solaria PowerX-400R vs Solaria Solaria PowerX-395R
One difference: module efficiency
Same series, other bin
Solaria
Solaria Solaria PowerX-400R vs Solaria Solaria PowerX-390R
3 differences, the largest is module efficiency
Same series, other bin
Solaria
Solaria SPV680-TG12-132BD vs Solaria SPV675-TG12-132BD
The same specification on paper
Same series, other bin
Solaria
Solaria SPV680-TG12-132BD vs Solaria SPV670-TG12-132BD
3 differences, the largest is module efficiency
Same series, other bin
Solaria
Solaria SPV680-TG12-132BD vs Solaria SPV665-TG12-132BD
3 differences, the largest is module efficiency
Same series, other bin
Solaria
Solaria SPV680-TG12-132BD vs Solaria SPV660-TG12-132BD
3 differences, the largest is module efficiency
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: Solaria Solaria PowerX-400R or Solaria SPV680-TG12-132BD?
According to our database: Solaria SPV680-TG12-132BD has higher module efficiency (21.92% vs 20.50%); Solaria SPV680-TG12-132BD tolerates heat better (temp coeff -0.300%/°C vs -0.360%/°C). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Solaria Solaria PowerX-400R and Solaria SPV680-TG12-132BD?
Solaria Solaria PowerX-400R has a module efficiency of 20.50%, while Solaria SPV680-TG12-132BD is 21.92%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Solaria Solaria PowerX-400R use vs Solaria SPV680-TG12-132BD?
Solaria Solaria PowerX-400R uses Monocrystalline cells; Solaria SPV680-TG12-132BD uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Solaria Solaria PowerX-400R and Solaria SPV680-TG12-132BD?
Solaria Solaria PowerX-400R has a 25 years power warranty; Solaria SPV680-TG12-132BD has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Solaria Solaria PowerX-400R and Solaria SPV680-TG12-132BD bifacial panels?
Solaria SPV680-TG12-132BD is bifacial (captures light from both faces); Solaria Solaria PowerX-400R is monofacial. Bifacial panels work best on ground mounts or raised structures with a light-coloured surface underneath.
Shop prices: See 1 Solaria offer
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.