Solar-Fabrik Mono S4 Halfcut BC White 490 vs Solar-Fabrik Mono S4 Halfcut BC Series White 490W

Solar-Fabrik
Mono S4 Halfcut BC White 490
490 Wp
24.00 %
Back Contact
Bifacial
Incomplete
VS

Solar-Fabrik
Mono S4 Halfcut BC Series White 490W
490 Wp
24.00 %
Back Contact
Bifacial
Incomplete
The verdict
Identical on every published parameter
All 17 comparable parameters agree, with 2 more left out because at least one datasheet does not publish them. Two records this alike are usually one panel sold under two names, or two bins of the same production line - decide on price and on who you would rather buy from.
How alike are they
17
of 17 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
0 of 17 parameters
What actually differs
Every comparable parameter agrees. The full specification is below.
02
What it means on a roof
Thirty years of production
A 1.0% first-year loss then 0.40% a year, assumed for both panels, at 1,200 kWh/kWp a year
Projected at 25 °C. Not published by Solar-Fabrik, so a hotter case cannot be shown without inventing one side of it.
White 490
16,440 kWh
Series White 490W
16,440 kWh
Lifetime gap
No difference
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
White 490
Series White 490W
Standard test conditions
25 °C
100.0% of rated power
490 W
-
Cool, bright day
40 °C
96.1% of rated power
471 W
-
Typical summer roof
55 °C
92.2% of rated power
452 W
-
Hot roof
70 °C
88.3% of rated power
433 W
-
03
Full specification
Parameter
White 490
Series White 490W
Difference
Power and efficiency
Rated power
490 Wp
490 Wp
Same
Module efficiency
24.00 %
24.00 %
Same
Power density
240.1 Wp/m²
240.1 Wp/m²
Same
Open-circuit voltage
40.75 V
40.75 V
Same
Voltage at max power
33.72 V
33.73 V
Effectively the same
Short-circuit current
15.18 A
15.18 A
Same
Current at max power
14.53 A
14.53 A
Same
Temperature
Temperature coefficient
-0.260 %/°C
-
Not published by Solar-Fabrik
Mechanical
Dimensions
1800x1134x30 mm
1800x1134x30 mm
Same
Module area
2.041 m²
2.041 m²
Same
Weight
25.0 kg
25.0 kg
Same
Weight per kWp
51.0 kg/kWp
51.0 kg/kWp
Same
Warranty and degradation
Product warranty
30 yrs
30 yrs
Same
Performance warranty
30 yrs
30 yrs
Same
Annual degradation
-
-
Neither datasheet publishes this
Technology
Cell technology
Back Contact
Back Contact
Same
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
108
108
Same
Bifacial
Yes
Yes
Same
04
14,354 panels
Against the whole database
Efficiency
#373
vs
#373
Tied - the same position in the database
Power density
#384
vs
#384
Tied - the same position in the database
Heat behaviour
#521
vs
#14,273
White 490 leads by 13,752 places
Weight
#4,434
vs
#4,434
Tied - the same position in the database
Warranty
#31
vs
#31
Tied - the same position in the database
Overall
#2,280
vs
#2,280
Tied - the same position in the database
05
Open the full database
More useful comparisons
Same series, other bin
Solar-Fabrik
Solar-Fabrik Mono S4 Halfcut BC White 490 vs Solar-Fabrik Mono S4 Halfcut BC White 485
One difference: module efficiency
Same series, other bin
Solar-Fabrik
Solar-Fabrik Mono S4 Halfcut BC White 490 vs Solar-Fabrik Mono S4 Halfcut BC White 480-490W
One difference: module efficiency
Same series, other bin
Solar-Fabrik
Solar-Fabrik Mono S4 Halfcut BC White 490 vs Solar-Fabrik Mono S4 Halfcut BC Series White 485W
One difference: module efficiency
Same series, other bin
Solar-Fabrik
Solar-Fabrik Mono S4 Halfcut BC White 490 vs Solar-Fabrik Mono S4 Halfcut BC White 480
3 differences, the largest is module efficiency
Same series, other bin
Solar-Fabrik
Solar-Fabrik Mono S4 Halfcut BC Series White 490W vs Solar-Fabrik Mono S4 Halfcut BC Series Full Black 480W
3 differences, the largest is module efficiency
Same series, other bin
Solar-Fabrik
Solar-Fabrik Mono S4 Halfcut BC Series White 490W vs Solar-Fabrik Mono S4 Halfcut BC Series Black 480W
3 differences, the largest is module efficiency
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: Solar-Fabrik Mono S4 Halfcut BC White 490 or Solar-Fabrik Mono S4 Halfcut BC Series White 490W?
According to our database: both panels are closely matched on key specs - the decision often comes down to price and local availability. See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Solar-Fabrik Mono S4 Halfcut BC White 490 and Solar-Fabrik Mono S4 Halfcut BC Series White 490W?
Solar-Fabrik Mono S4 Halfcut BC White 490 has a module efficiency of 24.00%, while Solar-Fabrik Mono S4 Halfcut BC Series White 490 W is 24.00%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Solar-Fabrik Mono S4 Halfcut BC White 490 use vs Solar-Fabrik Mono S4 Halfcut BC Series White 490W?
Solar-Fabrik Mono S4 Halfcut BC White 490 uses Back Contact cells; Solar-Fabrik Mono S4 Halfcut BC Series White 490 W uses Back Contact. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Solar-Fabrik Mono S4 Halfcut BC White 490 and Solar-Fabrik Mono S4 Halfcut BC Series White 490W?
Solar-Fabrik Mono S4 Halfcut BC White 490 has a 30 years power warranty; Solar-Fabrik Mono S4 Halfcut BC Series White 490 W has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Solar-Fabrik Mono S4 Halfcut BC White 490 and Solar-Fabrik Mono S4 Halfcut BC Series White 490W bifacial panels?
Both Solar-Fabrik Mono S4 Halfcut BC White 490 and Solar-Fabrik Mono S4 Halfcut BC Series White 490 W are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.
Shop prices: See 9 Solar-Fabrik offers
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.